Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Width | 17.5 mm |
---|---|
Height | 99 mm |
Depth | 114.5 mm |
Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
---|---|
Rated control supply current IS | typ. 55 mA |
Input voltage range | 20.4 V DC ... 26.4 V DC |
Power consumption at US | typ. 1.32 W |
Inrush current | max. 100 mA |
Typ. starting time with Us | 50 ms |
Typical release time | 50 ms |
Recovery time | 1 s |
Operating voltage display | 1 x yellow LED |
Protective circuit | Surge protection Suppressor diode, 33 V (A1 - A2) |
Maximum switching frequency | 0.5 Hz |
Filter time | max. 5 ms (at A1 in the event of voltage dips at Us) |
max. 2 ms (Test pulse width; high test pulse at A1/A2) | |
≥ 100 ms (Test pulse width; high test pulse at A1/A2) | |
Test pulse rate = 80 x Test pulse width | |
max. 5 ms (Test pulse width; low test pulse at A1/A2) | |
≥ 50 ms (Test pulse rate; low test pulse at A1/A2) | |
Test pulse rate = 15 x Test pulse width |
Contact type | 2 enabling current paths |
---|---|
1 confirmation current path | |
Contact material | AgCuNi, + 0.2 µm Au |
Maximum switching voltage | 250 V AC/DC (N/O contact / N/C contact, observe the load curve) |
Minimum switching voltage | 15 V AC/DC (N/O contact / N/C contact) |
Limiting continuous current | 5 A (N/O contact, pay attention to the derating) |
100 mA (N/C contact) | |
Maximum inrush current | 5 A (N/O contact) |
100 mA (N/C contact) | |
Inrush current, minimum | 5 mA (N/O contact / N/C contact) |
Sq. Total current | 50 A2 (observe derating) |
Interrupting rating (ohmic load) max. | 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W) |
192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W) | |
162 W (60 V DC, τ = 0 ms, N/C contact: 6 W) | |
66 W (110 V DC, τ = 0 ms, N/C contact: 11 W) | |
60 W (220 V DC, τ = 0 ms, N/C contact: 22 W) | |
1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA) | |
Maximum interrupting rating (inductive load) | 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W) |
43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W) | |
41 W (60 V DC, τ = 40 ms, N/C contact: 6 W) | |
35 W (110 V DC, τ = 40 ms, N/C contact: 11 W) | |
48 W (220 V DC, τ = 40 ms, N/C contact: 22 W) | |
Switching capacity | min. 75 mW |
Mechanical service life | 10x 106 cycles |
Output fuse | 10 A gL/gG (N/O contact) |
4 A gL/gG (for low-demand applications) | |
150 mA Fast-blow (N/C contact) |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 136.3 g |
Mounting position | any |
Mounting type | DIN rail mounting |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Housing material | Polyamide |
Housing color | yellow |
Connection method | Screw connection |
---|---|
pluggable | Yes |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Stop category in accordance with IEC 60204 | 0 |
---|---|
Designation | IEC 61508 - High demand |
Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Designation | IEC 61508 - Low demand |
Safety Integrity Level (SIL) | 2 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Designation | EN ISO 13849 |
Performance level (PL) | c (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
Category | 1 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %) |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 1 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Designation | EN 50156 |
Safety Integrity Level (SIL) | 2 |
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178/VDE 0160 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (31/32), (13/14, 23/24) |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Conformance | CE-compliant |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
ECLASS 10.0.1 | 27371819 |
---|---|
ECLASS 11.0 | 27371819 |
ECLASS 4.0 | 40020600 |
ECLASS 4.1 | 40020600 |
ECLASS 5.0 | 27371900 |
ECLASS 5.1 | 27371900 |
ECLASS 6.0 | 27371800 |
ECLASS 7.0 | 27371819 |
ECLASS 9.0 | 27371819 |
ETIM 2.0 | EC001449 |
---|---|
ETIM 3.0 | EC001449 |
ETIM 4.0 | EC001449 |
ETIM 6.0 | EC001449 |
ETIM 7.0 | EC001449 |
UNSPSC 6.01 | 30211901 |
---|---|
UNSPSC 7.0901 | 39121501 |
UNSPSC 11 | 39121501 |
UNSPSC 12.01 | 39121501 |
UNSPSC 13.2 | 39121501 |
UNSPSC 18.0 | 39122205 |
UNSPSC 19.0 | 39122205 |
UNSPSC 20.0 | 39122205 |
UNSPSC 21.0 | 39122205 |