Phoenix Contact STEP-DIODE/5-24DC/2X5/1X10 - 2868606 Redundancy module - Bộ chuyển nguồn dự phòng 5-24VDC 2x5A 1x10A

Phoenix Contact STEP-DIODE/5-24DC/2X5/1X10 - 2868606 Redundancy module - Bộ chuyển nguồn dự phòng 5-24VDC 2x5A 1x10A

863
Nhà sản xuất: Phoenix Contact;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Chi tiết thông tin đặc tính sản phẩm

Phoenix Contact STEP-DIODE/5-24DC/2X5/1X10 - 2868606 Redundancy module - Bộ chuyển nguồn dự phòng 5-24VDC 2x5A 1x10A

 

Product Description

A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, STEP DIODE provides the solution: decoupling with diode.

 

Your advantages

- Flexible mounting by simply snapping onto the DIN rail
- Save energy
- Rugged design
- Permanent monitoring of redundancy
- Consistent redundancy up to the load

 

Bản vẽ kỹ thuật




 

Dimensions

Width 18 mm
Height 90 mm
Depth 61 mm
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 30 mm / 30 mm


 

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2


 

Input data

Nominal input voltage range 5 V DC ... 24 V DC
  5 V DC ... 24 V DC
Input voltage range 4.5 V DC ... 30 V DC
Nominal input current 2x 5 A (-25 °C ... 55 °C)
  1x 10 A (-25 °C ... 55 °C)
  2x 5 A (-25 °C ... 55 °C)
  1x 10 A (-25 °C ... 55 °C)


 

Output data

Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 5 V DC ... 24 V DC
Nominal output current (IN) 10 A (Increasing power)
  5 A (Redundancy)
Derating 55 °C ... 70 °C (2.5%/K)
Connection in series No
Power loss nominal load max. 2.5 W (IOUT = 5 A)


 

General

Net weight 0.1 kg
Efficiency > 97 %
  > 97 %
MTBF (IEC 61709, SN 29500)  
  > 25822000 h (40 °C)
   
Degree of protection IP20
Protection class III
Housing material Plastic
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: 0 mm horizontally, 30 mm vertically


 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 6.5 mm
Screw thread M3


 

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 6.5 mm
Screw thread M3


 

Standards

Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)


 

Conformance/approvals

UL approvals UL/C-UL listed UL 508
  UL/C-UL Recognized UL 60950-1


 

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 4 kV (Test Level 2)
Discharge in air 8 kV (Test Level 3)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 2 GHz ... 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Comments Criterion B
Surge voltage load (surge) EN 61000-4-5
Input 2 kV (Test Level 3 - asymmetrical)
  1 kV (Test Level 2 - symmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
  1 kV (Test Level 2 - symmetrical)
Comments Criterion B
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 150 kHz ... 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Voltage dips EN 61000-4-11
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.


 

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


 

Classifications

eCl@ss

eCl@ss 10.0.1 27371010
eCl@ss 4.0 27250300
eCl@ss 4.1 27250300
eCl@ss 5.0 27371000
eCl@ss 5.1 27371000
eCl@ss 6.0 27371000
eCl@ss 7.0 27371010
eCl@ss 8.0 27371010
eCl@ss 9.0 27371010


 

ETIM

ETIM 3.0 EC000599
ETIM 4.0 EC002542
ETIM 5.0 EC002540
ETIM 6.0 EC002540
ETIM 7.0 EC002540


 

UNSPSC

UNSPSC 6.01 30211502
UNSPSC 7.0901 39121004
UNSPSC 11 39121004
UNSPSC 12.01 39121004
UNSPSC 13.2 39121004
UNSPSC 18.0 32151504
UNSPSC 19.0 32151504
UNSPSC 20.0 32151504
UNSPSC 21.0 32151504

- Xem chi tiết Tài liệu kỹ thuật, Hướng dẫn sử dụng/ Datasheet, Manuals, Catalogue Redundancy module STEP-DIODE/5-24DC/2X5/1X10 - 2868606 Phoenix Contact


Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại