Bộ lặp tín hiệu cấp nguồn Phoenix Contact MINI MCR-2-RPSS-I-2I-PT - 2905629
4-way power supply doubler with plug-in connection technology. HART-transparent, 0(4) mA ... 20 mA input signal, 0(4) mA ... 20 mA output signals. The device can be used in both signal and power supply doubler modes. Push-in connection technology.
Mô tả
The power supply duplicator with plug-in connection technology supplies the transmitter in the field and electrically isolates the input signal transmitted to two loads. HART data protocols can be transmitted bi-directionally via both outputs. You can use the device in signal and power supply duplicator mode with a transmitter supply voltage of >19.5 V. On the output side, the module can be connected to passive input cards. For a maximum load of ≤500 Ω per channel, electrically isolated analog standard signals 0 mA ... 20 mA or 4 mA ... 20 mA are available. The measuring transducer supports fault monitoring and NFC communication.
Thống số kỹ thuật
Notes
Utilization restriction |
EMC note |
EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product type |
Repeater power supplies |
Product family |
MINI Analog Pro |
No. of channels |
2 |
Type |
Signal conditioner |
Configuration |
DIP switches |
Insulation characteristics: GB Standard |
Overvoltage category |
II |
Pollution degree |
2 |
Electrical properties
No. of channels |
2 |
Electrical isolation |
4-way isolation |
Limit frequency (3 dB) |
> 1 kHz |
Signal transmission behavior |
In = Out |
Step response (10-90%) |
< 400 µs |
Maximum temperature coefficient |
0.0075 %/K |
Maximum transmission error |
0.05 % (of final value) |
Electrical isolation Input/output/power supply |
Rated insulation voltage |
300 Vrms |
Test voltage |
3 kV AC (50 Hz, 60 s) |
Insulation |
Reinforced insulation according to IEC/EN 61010-1 |
Supply |
Nominal supply voltage |
24 V DC |
Supply voltage range |
9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Typical current consumption |
40 mA (For 24 V DC and in signal duplicator mode) |
65 mA (For 24 V DC and in power supply duplicator mode) |
75 mA (For 12 V DC and in signal duplicator mode) |
130 mA (For 12 V DC and in power supply duplicator mode) |
Power consumption |
1.6 W (at IOUT = 20 mA, 500 Ω load) |
Input data
Signal: Current |
Description of the input |
Sensor circuit |
Number of inputs |
1 |
Current input signal |
0 mA ... 20 mA (Signal duplicator mode) |
4 mA ... 20 mA (Power supply and signal duplicator mode) |
Input resistance current input |
90 Ω (+1.6 V) |
Transmitter supply voltage |
> 19.5 V |
Output data
Signal: Current |
Number of outputs |
2 |
Non-load voltage |
< 20 V |
Current output signal |
0 mA ... 20 mA (Signal duplicator mode) |
4 mA ... 20 mA (Power supply and signal duplicator mode) |
Max. current output signal |
25 mA |
Load/output load current output |
≤ 500 Ω (per channel) |
Ripple |
< 20 mVPP (500 Ω) |
Connection data
Connection method |
Push-in connection |
Stripping length |
10 mm |
Conductor cross section rigid |
0.2 mm² ... 2.5 mm² (with ferrule) |
0.14 mm² ... 2.5 mm² (without ferrule) |
Conductor cross section flexible |
0.14 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 12 (flexible) |
Ex data
Ex installation (EPL) |
Gc |
Div. 2 |
Interfaces
Data communication (bypass) |
HART function |
Yes |
Limit frequency (3 dB) |
1 kHz |
Signaling
Status display |
Green LED (supply voltage) |
Dimensions
Width |
6.2 mm |
Height |
109.81 mm |
Depth |
119.2 mm |
Material specifications
Fire protection for rail vehicles (DIN EN 45545-2) R22 |
HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 |
HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 |
HL 1 - HL 2 |
Housing material |
PBT |
Environmental and real-life conditions
Ambient conditions |
Degree of protection |
IP20 (not assessed by UL) |
Ambient temperature (operation) |
-40 °C ... 70 °C |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Altitude |
≤ 2000 m |
Permissible humidity (operation) |
5 % ... 95 % (non-condensing) |
Approvals
CE |
Certificate |
CE-compliant |
ATEX |
Identification |
II 3 G Ex ec ic IIC T4 Gc |
Certificate |
BVS 19 ATEX E 047 X |
UKCA Ex (UKEX) |
Identification |
II 3 G Ex ec ic IIC T4 Gc |
Certificate |
PxCIF21UKEX2902000X |
IECEx |
Identification |
Ex ec ic IIC T4 Gc |
Certificate |
IECEx BVS 19.0041X |
CCC / China-Ex |
Identification |
Ex nA ic IIC T4 Gc |
UL, USA/Canada |
Identification |
UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T5 |
Class I, Zone 2, Group IIC T5 |
Shipbuilding approval |
Certificate |
DNV GL TAA000021E Rev. 1 |
EAC Ex |
Identification |
2Ex ec ic IIC T4 Gc |
Certificate |
BY/112 02.01 TP012 103.01 00081 |
DNV GL data |
Temperature |
B |
Humidity |
B |
Vibration |
A |
EMC |
A |
Enclosure |
Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity |
EN 61000-6-2 |
Note |
When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility |
Conformance with EMC directive |
Noise emission |
EN 61000-6-4 |
Electrostatic discharge |
Standards/regulations |
EN 61000-4-2 |
Electrostatic discharge |
Comments |
Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field |
Designation |
Electromagnetic RF field |
Standards/regulations |
EN 61000-4-3 |
Fast transients (burst) |
Designation |
Fast transients (burst) |
Standards/regulations |
EN 61000-4-4 |
Surge current load (surge) |
Standards/regulations |
EN 61000-4-5 |
Conducted interference |
Designation |
Conducted interferences |
Standards/regulations |
EN 61000-4-6 |
Standards and regulations
Electrical isolation |
4-way isolation |
GB Standard |
Standards/regulations |
GB 3836.1 |
GB 3836.4 |
GB 3836.8 |
Mounting
Mounting type |
DIN rail mounting |
Assembly instructions |
The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting position |
any |
Commercial data
Item number |
2905629 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product key |
CK1411 |
Catalog page |
Page 78 (C-5-2019) |
GTIN |
4046356999441 |
Weight per piece (including packing) |
120.6 g |
Weight per piece (excluding packing) |
120 g |
Customs tariff number |
85437090 |
Country of origin |
DE |
Classifications
ECLASS
ECLASS-11.0 |
27210120 |
ECLASS-12.0 |
27210120 |
ECLASS-13.0 |
27210120 |
ETIM
UNSPSC
Approvals
EAC
Approval ID: RU*DE.*08.B.01608/19
DNV GL
Approval ID: TAA000021E
UL Listed
Approval ID: FILE E 238705
CCC
Approval ID: 2021322303003858
cUL Listed
Approval ID: FILE E 238705
IECEx
Approval ID: IECEx BVS 19.0041X
cUL Listed
Approval ID: FILE E 196811
UL Listed
Approval ID: FILE E 196811
ATEX
Approval ID: BVS 19 ATEX E 047 X
cULus Listed
cULus Listed
Environmental product compliance
|
REACh SVHC |
Lead 7439-92-1 |
|
China RoHS |
Environmentally Friendly Use Period = 50 years |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
- Tài liệu kỹ thuật Phoenix Contact MINI MCR-2-RPSS-I-2I-PT - 2905629
ở đây.
Tham khảo thêm các model khác cùng loại:
MACX MCR-T-UI-UP - Temperature measuring transducer
2811394
Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
MACX MCR-UI-UI-UP-NC - Signal conditioner
2811297
Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.
MACX MCR-UI-UI-NC - Signal conditioner
2811446
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.
MACX MCR-UI-UI-UP-SP-NC - Signal conditioner
2811569
Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), spring-cage connection, SIL.
MACX MCR-SL-RPSSI-I - Power/input isolating amplifier
2865955
Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 in accordance with IEC 61508.
MACX MCR-UI-UI - Signal conditioner
2811284
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL.
MACX MCR-SL-I-I-ILP - Loop-powered isolators
2905278
1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
MACX MCR-SL-RPSSI-2I - Repeater power supply
2924825
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.
MACX MCR-T-UIREL-UP - Temperature measuring transducer
2811378
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
MACX MCR-SL-RPSSI-I-SP - Power/input isolating amplifier
2924207
Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 in accordance with IEC 61508.
MACX MCR-T-UI-UP-SP - Temperature measuring transducer
2811860
Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
MACX MCR-SL-NAM-R-SP - Isolation amplifier
2924252
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with Push-in connection.
MACX MCR-SL-2NAM-RO - Isolation amplifier
2865049
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
MACX MCR-SL-2NAM-R-UP - Isolation amplifier
2865052
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, screw connection, SIL 2.
MACX MCR-UI-UI-SP-NC - Signal conditioner
2811556
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), spring-cage connection, SIL.
MACX MCR-RTD-I - Temperature measuring transducer
1050192
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.
MACX MCR-SL-RPSS-2I-2I - Repeater power supply
2904089
2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, screw connection, SIL, PL.
MACX MCR-SL-2NAM-RO-SP - Isolation amplifier
2924294
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
MACX MCR-IDS-I-I-SP - Output signal conditioner
2908064
Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
MACX MCR-SL-NAM-2RO - Isolation amplifier
2865010
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, screw connection.
MACX MCR-T-UIREL-UP-SP - Temperature measuring transducer
2811828
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
MACX MCR-SL-2I-2I-ILP - Loop-powered isolators
2905280
2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
MACX MCR-SL-NAM-R - Isolation amplifier
2865997
NAMUR signal conditioners for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with screw connection.
MACX MCR-SL-2NAM-R-UP-SP - Isolation amplifier
2924304
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
MACX MCR-SL-RPSSI-I-UP-SP - Repeater power supply
2924210
Repeater power supply for supplying 2- and 3-conductor transmitters with HART transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), Push-in connection
MACX MCR-SL-NAM-2RO-SP - Isolation amplifier
2924265
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection.
MACX MCR-SL-RPSSI-I-UP - Repeater power supply
2865968
Repeater power supply for supplying 2- and 3-conductor transmitters with Hart transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), screw connection
MACX MCR-RTD-I-SP - Temperature measuring transducer
1050201
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.
MACX MCR-SL-NAM-2T - Isolation amplifier
2865023
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
MINI MCR-SL-PT100-UI-NC - Resistance thermometer measuring transducer
2864273
MCR temperature transducer for Pt 100 temperature sensors, configured via DIP switches, with screw connection, not preconfigured
MACX MCR-T-UI-UP-C - Temperature measuring transducer
2811873
Freely programmable temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
MACX MCR-SL-RPSS-2I-2I-SP - Repeater power supply
2904090
2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, Push-in connection, SIL, PL.
MACX MCR-UI-UI-UP - Signal conditioner
2811459
Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL.
MINI MCR-SL-UI-2I-NC - Signal duplicator
2864176
4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration
MINI MCR-SL-R-UI - Resistance/potiposition transducer
2864095
MCR potiposition transducer for conversion of potentiometer positions into a standard analog signal, 0 Ω input... 100 Ω to 0 kΩ ... 100 kΩ
MINI MCR-2-UI-UI-PT - Signal conditioner
2902040
3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover, for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. push-in connection technology, standard configuration.
MINI MCR-2-UNI-UI-2UI-PT - Signal duplicator
2905028
Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
MINI MCR-SL-I-I - Signal conditioner
2864406
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0(4) mA ... 20 mA, output signal: 0(4) mA ... 20 mA
MINI MCR-SL-UI-UI-NC - Signal conditioner
2864150
3-way isolating amplifier for the electrical isolation of analog signals, I/O can be configured via DIP switches, with screw connection, standard configuration
MINI MCR-2-UNI-UI-2UI - Signal duplicator
2905026
Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Screw connection technology, standard configuration.
MINI MCR-SL-RPS-I-I - Repeater power supply
2864422
MCR repeater power supplies, screw connection, input signal: (0)4..20 mA, output signal: (0)4..20 mA
MINI MCR-SL-RPSS-I-I - Repeater power supply
2864079
MCR repeater power supply with HART transparency, input signal: 4 mA ... 20 mA, output signal: 4 mA ... 20 mA, with screw connection
MINI MCR-2-UI-UI - Signal conditioner
2902037
3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, standard configuration.
MINI MCR-2-RTD-UI - Resistance thermometer measuring transducer
2902049
Configurable temperature transducer with plug-in connection technology for connecting 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Configurable via DIP switch or software. Screw connection technology, standard configuration
MINI MCR-2-I-I - Signal conditioner
2901998
3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0(4) mA ... 20 mA, output signal: 0(4) mA ... 20 mA, screw connection technology
MINI MCR-2-U-U - Signal conditioner
2902042
3-way signal conditioner with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input signal: 0 ... 10 V/±10 V, output signal: 0 ... 10 V/±10 V, screw connection technology
MINI MCR-2-F-UI - Frequency measuring transducer
2902056
Universally configurable frequency transducer for converting frequency (Hz/rpm) and PWM signals into standard signals. Sensor voltages greater than 8.2 V DC are possible in combination with MINI MCR-2-SPS 1033202. Screw connection technology.
MINI MCR-SL-PT100-LP-NC - Temperature measuring transducer
2810308
Configurable loop-powered temperature transducer for Pt 100 temperature sensors, configured via DIP switches, with screw connection, not preconfigured
MACX MCR-SL-2NAM-T - Isolation amplifier
2865036
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
MACX MCR-SL-RPSSI-2I-SP - Repeater power supply
2924838
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 mA … 20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL.
MINI MCR-TC-UI-NC - Thermocouple measuring transducer
2902851
Configurable temperature transducer for the connection of thermocouples. Can be configured via DIP switches or, with extended functionality, using the software. Screw connection, standard configuration.
MINI MCR-SL-1CP-I-I - Loop-powered isolators
2864419
MCR loop-powered isolator, 1-channel, for the electrical isolation of current signals without auxiliary power, with screw connection
MINI MCR-2-RPSS-I-2I-PT - Repeater power supply
2905629
4-way power supply doubler with plug-in connection technology. HART-transparent, 0(4) mA ... 20 mA input signal, 0(4) mA ... 20 mA output signals. The device can be used in both signal and power supply doubler modes. Push-in connection technology.
MINI MCR-2-RPSS-I-I-PT - Repeater power supply
2902015
3-way repeater power supply with plug-in connection technology. HART-transparent, input signal 0(4) mA ... 20 mA, output signal 0(4) mA ... 20 mA. The device can be used in both isolator and repeater power supply operation. push-in connection technology
MINI MCR-2-RTD-UI-PT - Resistance thermometer measuring transducer
2902052
Configurable temperature transducer with plug-in connection technology for connecting 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Configurable via DIP switch or software. push-in connection technology, standard configuration
MINI MCR-2-I-I-ILP - Loop-powered isolators
2901994
1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
MINI MCR-2-TC-UI - Thermocouple measuring transducer
2902055
Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Screw connection technology, standard configuration
MINI MCR-SL-2CP-I-I - Loop-powered isolators
2864655
MCR passive isolator, 2-channel, for the electrical isolation of current signals without auxiliary power, with screw connection
MINI MCR-SL-PT100-UI-200-NC - Temperature measuring transducer
2864370
MCR temperature transducer, configurable, for Pt 100 temperature sensors, with screw-connection, not configured
MINI MCR-RTD-UI-NC - Resistance thermometer measuring transducer
2902849
Configurable temperature transducer for the connection of 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Can be configured via DIP switches or, with extended functionality, using the software. Screw connection, standard configuration.
MACX MCR-SL-I-I-ILP-SP - Loop-powered isolators
2905279
1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
MACX MCR-RTD-I-C - Temperature measuring transducer
1052472
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, order configuration.
MACX MCR-RTD-I-SP-C - Temperature measuring transducer
1052464
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, order configuration.
MACX MCR-T-UI-UP-SP-C - Temperature measuring transducer
2811970
Freely programmable temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
MACX MCR-UI-UI-UP-SP - Signal conditioner
2811585
Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL.
MACX MCR-SL-2I-2I-ILP-SP - Loop-powered isolators
2905281
2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
MACX MCR-T-UIREL-UP-SP-C - Temperature measuring transducer
2811831
Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
MACX MCR-SL-2NAM-T-SP - Isolation amplifier
2924281
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
MACX MCR-TC-I-C - Temperature measuring transducer
1052459
Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Order configuration, freely programmable, 3-way electrical isolation, screw connection, SIL.
MACX MCR-SL-NAM-2T-SP - Isolation amplifier
2924278
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
MACX MCR-IDS-2I-2I-SP - Output signal conditioner
2908066
2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
MACX MCR-TC-I - Temperature measuring transducer
1050228
Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Freely programmable, 3-way electrical isolation, screw connection, SIL.
MACX MCR-UI-UI-SP - Signal conditioner
2811572
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL.
MACX MCR-IDS-2I-2I - Output signal conditioner
2908065
2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection.
MACX MCR-T-UIREL-UP-C - Temperature measuring transducer
2811514
Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
MACX MCR-IDS-I-I - Output signal conditioner
2908063
Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.
MINI MCR-2-U-I4-PT - Signal conditioner
2902030
3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0 V ... 10 V, output signal: 4 mA ... 20 mA, push-in connection technology
MINI MCR-SL-I-U-4 - Signal conditioner
2813538
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 4 mA ... 20 mA, output signal: 0 A ... 10 V
MINI MCR-SL-CVS-24-5-10-NC - Constant voltage source
2902822
Constant voltage source, input voltage 9.6 - 30 V DC, output voltage 10 V, 7.5 V, 5 V, 2.5 V DC, electrically isolated, can be configured via DIP switches, screw connection technology, standard configuration
MINI MCR-2-I-I-PT - Signal conditioner
2901999
3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0(4) mA ... 20 mA, output signal: 0(4) mA ... 20 mA, push-in connection technology.
MINI MCR-SL-F-UI-NC - Frequency measuring transducer
2902832
The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration.
MINI MCR-SL-IDS-I-I - Output signal conditioner
2905577
3-way output signal conditioner for transmitting 0/4 ... 20 mA signals from the controller to a load located in the field with simultaneous 3-way electrical isolation between the input, output, and supply, with screw connection
MINI MCR-SL-SHUNT-UI-NC - Signal conditioner
2810780
MCR 3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV range, both unipolar and bipolar with screw connection, not preconfigured
MINI MCR-2-RPSS-I-2I - Repeater power supply
2905628
4-way power supply doubler with plug-in connection technology. HART-transparent, 0(4) mA ... 20 mA input signal, 0(4) mA ... 20 mA output signals. The device can be used in both signal and power supply doubler modes. Screw connection technology.
MINI MCR-2-UI-UI-C - Signal conditioner
2902036
3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, order configuration.
MINI MCR-2-U-I4 - Signal conditioner
2902029
3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0 V ... 10 V, output signal: 4 mA ... 20 mA, screw connection technology
MINI MCR-2-POT-UI - Resistance/potiposition transducer
2902016
Configurable potiposition transducer with plug-in connection technology for connecting potentiometers from 0 Ω ... 100 Ω to 0 kΩ ... 100 kΩ. Configurable via DIP switch or software. Screw connection technology, standard configuration
MINI MCR-2-POT-UI-PT - Resistance/potiposition transducer
2902017
Configurable potiposition transducer with plug-in connection technology for connecting potentiometers from 0 Ω ... 100 Ω to 0 kΩ ... 100 kΩ. Configurable via DIP switch or software. push-in connection technology, standard configuration
MINI MCR-SL-UI-I-LP-NC - Signal conditioner
2902829
2-way loop-powered isolating amplifier (supplied on the output side), can be configured via DIP switches, with screw connection technology and standard configuration.
MINI MCR-SL-U-UI-NC - Signal conditioner
2865007
MCR 3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals up to 30 V, with screw connection, standard configuration
MINI MCR-2-U-UI - Signal conditioner
2902019
3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV and V range, unipolar as well as bipolar. Screw connection technology, standard configuration.
MINI MCR-2-UI-I-OLP - Loop-powered isolators
2902061
Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input configurable via DIP switch. Screw connection technology, standard configuration.
MINI MCR-SL-UI-REL - Limit value switch
2864480
MCR limit value switch, with adjustable hysteresis and delay time, with screw connection
MINI MCR-SL-UI-F - Frequency measuring transducer
2864082
Analog frequency transducers for converting analog standard signals into frequency signals or PWM signals, configurable via DIP switch, with screw connection
MACX MCR-SL-UI-REL-SP - Limit value switch
2906170
Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.
MINI MCR-2-I4-U-PT - Signal conditioner
2902003
3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 4 mA ... 20 mA, output signal: 0 V ... 10 V, push-in connection technology
MINI MCR-SL-U-I-4 - Signal conditioner
2813525
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0 V ... 10 V, output signal: 4 mA ... 20 mA
MINI MCR-2-UI-FRO-PT - Frequency measuring transducer
2902032
Analog frequency transducer with limit value functionality and plug-in connection technology for converting standard signals into frequency or PWM signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
MINI MCR-2-U-UI-PT - Signal conditioner
2902021
3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV and V range, unipolar as well as bipolar. Push-in connection technology, standard configuration.
MINI MCR-2-UNI-UI-UIRO - Signal conditioner
2902026
Universally configurable 4-way signal conditioner, with switching output and plug-in connection technology for the electrical isolation of analog signals. Configurable via DIP switch or software. Screw connection technology, standard configuration.
MINI MCR-2-UI-REL-PT - Limit value switch
2902035
Universally configurable threshold value switch with changeover contact relay output and plug-in connection technology for switching analog limit values. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
MINI MCR-2-2I-2I-ILP-PT - Loop-powered isolators
2901997
2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
MINI MCR-2-TC-UI-PT - Thermocouple measuring transducer
2905249
Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, standard configuration
MINI MCR-2-RTD-UI-C - Resistance thermometer measuring transducer
2902048
Configurable temperature transducer with plug-in connection technology for connecting 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Configurable via DIP switch or software. Screw connection technology, order configuration
MINI MCR-2-F-UI-PT - Frequency measuring transducer
2902058
Universally configurable frequency transducer for converting frequency (Hz/rpm) and PWM signals into standard signals. Sensor voltages greater than 8.2 V DC are possible in combination with MINI MCR-2-SPS-PT 1033201. Push-in connection technology.
MINI MCR-2-RPS-2I-2I-OLP-PT - Repeater power supply
2906449
Two-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
MINI MCR-2-NAM-2RO - Isolation amplifier
2902004
Configurable NAMUR signal conditioner with plug-in connection technology for proximity sensors, floating switch contacts, and switch contacts with resistance circuit. 2 transistor outputs, configurable via DIP switch. Screw connection technology.
MACX MCR-SL-I-I-HV-ILP-SP - Loop-powered isolators
2907705
1-channel input loop-powered 2-way isolator with increased isolating voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
MINI MCR-SL-I-U-0 - Signal conditioner
2813541
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0 mA ... 20 mA, output signal: 0 V ... 10 V
MINI MCR-2-UNI-UI-2UI-C - Signal duplicator
2905025
Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Screw connection technology, order configuration.
MINI MCR-SL-U-U - Signal conditioner
2864684
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0 ... 10 V/±10 V, output signal: 0 ... 10 V/±10 V
MINI MCR-2-NAM-2RO-PT - Isolation amplifier
2902005
Configurable NAMUR signal conditioner with plug-in connection tec