Cảm biến cảm ứng | Inductive sensors

Các models thuộc dòng Cảm biến tiệm cận cảm ứng E2V-X của Omron | E2V-X Series Ferrous and non-ferrous cylindrical inductive proximity sensors

Dòng cảm biến tiệm cận cảm ứng hình trụ bằng sắt và không màu trong vỏ nhựa. DC 3-wire proximity sensors: M12, M18, M30, - Standard and Long-distance detection in pre-wired or connector models, - Nickel-plated brass housing
Các models thuộc dòng Cảm biến tiệm cận cảm ứng E2V-X của Omron | E2V-X Series Ferrous and non-ferrous cylindrical inductive proximity sensors

E2V-X

Ferrous and Non-Ferrous Cylindrical Proximity Sensor
The E2V-X provides long-distance detection of aluminum or iron, while mounted flush in metal.
Highly visible indicator

- DC 3-wire proximity sensors: M12, M18, M30
- Standard and Long-distance detection in pre-wired or connector models
- Nickel-plated brass housing

Các models
Model   E2V-X2B1   Operation mode NO   Shielded     Size   M122mm Output PNP
Model   E2V-X2C1   Operation mode NO   Shielded     Size   M122mm Output NPN
Model   E2V-X5B1   Operation mode NO   Shielded     Size   M185mm Output PNP
Model   E2V-X5C1   Operation mode NO   Shielded     Size   M185mm Output NPN
Model   E2V-X10B1   Operation mode NO   Shielded     Size   M3010mm Output PNP
Model   E2V-X10C1   Operation mode NO   Shielded     Size   M3010mm Output NPN
Model   E2V-X2B2   Operation mode NC   Shielded     Size   M122mm Output PNP
Model   E2V-X2C2   Operation mode NC   Shielded     Size   M122mm Output NPN
Model   E2V-X5B2   Operation mode NC   Shielded     Size   M185mm Output PNP
Model   E2V-X5C2   Operation mode NC   Shielded     Size   M185mm Output NPN
Model   E2V-X10B2   Operation mode NC   Shielded     Size   M3010mm Output PNP
Model   E2V-X10C2   Operation mode NC   Shielded     Size   M3010mm Output NPN
Model   E2V-X4B1   Operation mode NO   Shielded     SizeM12     Sensing distance   4mm     Output PNP
Model   E2V-X4C1   Operation mode NO   Shielded     SizeM12     Sensing distance   4mm     Output NPN
Model   E2V-X8B1   Operation mode NO   Shielded     SizeM18     Sensing distance   8mm     Output PNP
Model   E2V-X8C1   Operation mode NO   Shielded     SizeM18     Sensing distance   8mm     Output NPN
Model   E2V-X15B1   Operation mode NO   Shielded     SizeM30     Sensing distance   15mm     Output PNP
Model   E2V-X15C1   Operation mode NO   Shielded     SizeM30     Sensing distance   15mm     Output NPN
Model   E2V-X4B2   Operation mode NC   Shielded     SizeM12     Sensing distance   4mm     Output PNP
Model   E2V-X4C2   Operation mode NC   Shielded     SizeM12     Sensing distance   4mm     Output NPN
Model   E2V-X8B2   Operation mode NC   Shielded     SizeM18     Sensing distance   8mm     Output PNP
Model   E2V-X8C2   Operation mode NC   Shielded     SizeM18     Sensing distance   8mm     Output NPN
Model   E2V-X15B2   Operation mode NC   Shielded     SizeM30     Sensing distance   15mm     Output PNP
Model   E2V-X15C2   Operation mode NC   Shielded     SizeM30     Sensing distance   15mm     Output NPN
Model   E2V-X4B1-M1   Shielded     Size   M12     Sensing distance   4mm     Output PNP
Model   E2V-X4C1-M1   Shielded     Size   M12     Sensing distance   4mm     Output NPN
Model   E2V-X8B1-M1   Shielded     Size   M18     Sensing distance   8mm     Output PNP
Model   E2V-X8C1-M1   Shielded     Size   M18     Sensing distance   8mm     Output NPN
Model   E2V-X15B1-M1   Shielded     Size   M30     Sensing distance   15mm     Output PNP
Model   E2V-X15C1-M1   Shielded     Size   M30     Sensing distance   15mm     Output NPN
Model   E2V-X4B2-M1   Shielded     Size   M12     Sensing distance   4mm     Output PNP
Model   E2V-X4C2-M1   Shielded     Size   M12     Sensing distance   4mm     Output NPN
Model   E2V-X8B2-M1   Shielded     Size   M18     Sensing distance   8mm     Output PNP
Model   E2V-X8C2-M1   Shielded     Size   M18     Sensing distance   8mm     Output NPN
Model   E2V-X15B2-M1   Shielded     Size   M30     Sensing distance   15mm     Output PNP
Model   E2V-X15C2-M1   Shielded     Size   M30     Sensing distance   15mm     Operation mode Output NPN
Model   E2V-X4B1-M1TJ   Operation mode NO      Shielded     Size   M12     Sensing distance   4mm     Output   PNP
Model   E2V-X4C1-M1TJ   Operation mode NO      Shielded     Size   M12     Sensing distance   4mm     Output   NPN
Model   E2V-X8B1-M1TJ   Operation mode NO      Shielded     Size   M18     Sensing distance   8mm     Output   PNP
Model   E2V-X8C1-M1TJ   Operation mode NO      Shielded     Size   M18     Sensing distance   8mm     Output   NPN
Model   E2V-X15B1-M1TJ   Operation mode NO      Shielded     Size   M30     Sensing distance   15mm     Output   PNP
Model   E2V-X15C1-M1TJ   Operation mode NO      Shielded     Size   M30     Sensing distance   15mm     Output   NPN

Specifications
Item/ Model E2V-X2 - -
Size M12
Sensing distance 2mm±10%
Set distance 0 to 1.6 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Standard sensing object Aluminum: 12 × 12 × 3 mm
Response frequency* 150Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Control
output Load current
Open-collector output, 100 mA max.
Control Residual voltage
output
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
Operation mode B1/C1 Models: NO
B2/C2 Models: NC  (Refer to the timing charts under I/O Circuit Diagrams for details.)
Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
  ±10% max.
Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MW min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s10 times each in X, Y, and Z directions
Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Weight (packed state)  Cable Approx. 120 g
Weight (packed state)  Connector Approx. 30 g
Weight (packed state) Pre-wired Connector Models Approx. 50 g
Material Case Nickel-plated brass
Material sensing surface Heat-resistant ABS
Material Clamping nuts Nickel-plated brass
Material Toothed whasher Zinc-plated iron
Accessories Instruction manual
 
Item/ Model E2V-X4 - -
Size M12
Sensing distance 4mm±10%
Set distance 0 to 3.2 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Standard sensing object Aluminum: 12 × 12 × 3 mm
Response frequency* 40Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Control
output Load current
Open-collector output, 100 mA max.
Control Residual voltage
output
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
Operation mode B1/C1 Models: NO
B2/C2 Models: NC  (Refer to the timing charts under I/O Circuit Diagrams for details.)
Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
  ±15% max.
Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MW min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s10 times each in X, Y, and Z directions
Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Weight (packed state)  Cable Approx. 120 g
Weight (packed state)  Connector Approx. 30 g
Weight (packed state) Pre-wired Connector Models Approx. 50 g
Material Case Nickel-plated brass
Material sensing surface Heat-resistant ABS
Material Clamping nuts Nickel-plated brass
Material Toothed whasher Zinc-plated iron
Accessories Instruction manual
 
Item/ Model E2V-X5 - -
Size M18
Sensing distance 5mm±10%
Set distance 0 to 4.0 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Standard sensing object Aluminum: 18 × 18 × 3 mm
Response frequency* 70Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Control
output Load current
Open-collector output, 100 mA max.
Control Residual voltage
output
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
Operation mode B1/C1 Models: NO
B2/C2 Models: NC  (Refer to the timing charts under I/O Circuit Diagrams for details.)
Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
  ±10% max.
Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MW min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s10 times each in X, Y, and Z directions
Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Weight (packed state)  Cable Approx. 150 g
Weight (packed state)  Connector Approx. 45 g
Weight (packed state) Pre-wired Connector Models Approx. 70 g
Material Case Nickel-plated brass
Material sensing surface Heat-resistant ABS
Material Clamping nuts Nickel-plated brass
Material Toothed whasher Zinc-plated iron
Accessories Instruction manual
 
Item/ Model E2V-X8 - -
Size M18
Sensing distance 8mm±10%
Set distance 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Standard sensing object Aluminum: 24 × 24 × 3 mm
Response frequency* 40Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Control
output Load current
Open-collector output, 100 mA max.
Control Residual voltage
output
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
Operation mode B1/C1 Models: NO
B2/C2 Models: NC  (Refer to the timing charts under I/O Circuit Diagrams for details.)
Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
  ±15% max.
Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MW min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s10 times each in X, Y, and Z directions
Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Weight (packed state)  Cable Approx. 150 g
Weight (packed state)  Connector Approx. 45 g
Weight (packed state) Pre-wired Connector Models Approx. 70 g
Material Case Nickel-plated brass
Material sensing surface Heat-resistant ABS
Material Clamping nuts Nickel-plated brass
Material Toothed whasher Zinc-plated iron
Accessories Instruction manual
 
Item/ Model E2V-X10 - -
Size M30
Sensing distance 10mm±10%
Set distance 0 to 8.0 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Standard sensing object Aluminum: 30 × 30 × 3 mm
Response frequency* 70Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Control
output Load current
Open-collector output, 100 mA max.
Control Residual voltage
output
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
Operation mode B1/C1 Models: NO
B2/C2 Models: NC  (Refer to the timing charts under I/O Circuit Diagrams for details.)
Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
  ±10% max.
Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MW min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s10 times each in X, Y, and Z directions
Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Weight (packed state)  Cable Approx. 200 g
Weight (packed state)  Connector Approx. 120 g
Weight (packed state) Pre-wired Connector Models Approx. 140 g
Material Case Nickel-plated brass
Material sensing surface Heat-resistant ABS
Material Clamping nuts Nickel-plated brass
Material Toothed whasher Zinc-plated iron
Accessories Instruction manual
 
Item/ Model E2V-X15 - -
Size M30
Sensing distance 15mm±10%
Set distance 0 to 12.0 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Standard sensing object Aluminum: 45 × 45 × 3 mm
Response frequency* 30Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Control
output Load current
Open-collector output, 100 mA max.
Control Residual voltage
output
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
Operation mode B1/C1 Models: NO
B2/C2 Models: NC  (Refer to the timing charts under I/O Circuit Diagrams for details.)
Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
  ±15% max.
Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MW min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s10 times each in X, Y, and Z directions
Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Weight (packed state)  Cable Approx. 200 g
Weight (packed state)  Connector Approx. 120 g
Weight (packed state) Pre-wired Connector Models Approx. 140 g
Material Case Nickel-plated brass
Material sensing surface Heat-resistant ABS
Material Clamping nuts Nickel-plated brass
Material Toothed whasher Zinc-plated iron
Accessories Instruction manual