Chi tiết thông tin đặc tính sản phẩm
Cảm biến tốc độ Lenord+Bauer GEL 2478EWM350KBNW10 | Speed sensor
(square wave 29-0.05mm 90o)
Key Features
- Contactless measurement of linear or rotational movements
- One or two channels
- Magnetic measurement principle
- Optionally available with:
EC type-examination certificate
BVS 07 ATEX E 030
II 2 G Ex ib IIB T 4
Features
- Can be used under very harsh conditions
- Registers speed between 0 Hz and a maximum of 25 kHz
- Uses target wheels with modules1.0 to 3.5 (D.P.= 25.4 - 7.3) or measuring rods with 4.0 mm pitch
- Large measuring distance (air gap) of up to 3 mm (depending on the gear module or the pitch of the target)
- Very precise duty and phase shift of the output signals
- Robust stainless steel housing
- Very high protection class IP 68
- Wide temperature –40°C to + 85°C (ATEX ) or –40°C...+120°C without ATEX certificate
Technical Data
Electrical Data |
Supply voltage VS |
10 ... 28 V DC (ATEX); VS = 10 ... 30 V DC without ATEX certificate, protected against polarity reversal |
Safety-related parameters |
See section "Safety information" |
Power consumption without load |
IB < 45 mA |
Output Signal |
Square-wave, short circuit-proof |
Output voltage |
High = VS - 1.8 V; Low = U < 0.5 V |
Slew rate of output signal |
> 10 V / µs |
Maximum output current per channel |
< 10 mA |
Frequency Range |
0 Hz... 25 KHz |
Duty ratio of output signal |
50 % ± 5 % |
Phase shift tracks 1 and 2 |
90° ± 20° |
Electromagnetic compatibility |
rail vehicles: EN 50121-3-2
industry applications: EN 61000-6-1 to 4 |
Mechanical data |
Isolation strength (EN 60439-1) |
500 V AC |
Vibration protection (EN 61373 Kat.3) |
200 m/s2 |
Shock protection (EN 61373 Kat.3) |
2000 m/s2 |
Air Gap |
See table "air gap" |
Module of target wheel
Pitch of measuring rod |
M = 1.0 ... 3.5
p = 4.0 mm |
Operating and ambient temperature range |
-40 °C ... + 85 °C (ATEX) or -40°C ... +120°C without ATEX certification |
Storage temperature range |
-40 °C ... + 120 °C |
Screen connection |
Connected to sensor housing |
Cable |
PUR or silicone depending on the version * |
Type of Connection |
6-core cable outlet (see cable assignment) |
Cable cross-section |
6 x 1.0 mm2 (PUR), 6 x 0.75 mm2 (silicone) |
External diameter of cable |
da = 8.1 mm ± 0.2 mm (PUR) or da = 9.2 mm ± 0.4 mm (silicone) |
Protection class |
IP 68 |
Housing |
Stainless steel; material 1.4305 |
Resistance of the measuring side |
< 5 bar |
* Cable specification:
LK 1069 = PUR LK 10581 = silicone on request
Air gap depending on module or pitch
Measuring scale |
Module/Pitch |
Air gap |
Measuring Target Wheels |
M = 1.0 |
a = 0.2 ... 1.4 mm |
Measuring Target Wheels |
M = 1.5 |
a = 0.2 ... 1.8 mm |
Measuring Target Wheels |
M = 2.0 |
a = 0.2 ... 2.2 mm |
Measuring Target Wheels |
M = 2.5 |
a = 0.2 ... 2.8 mm |
Measuring Target Wheels |
M = 3.5 |
a = 0.2 ... 3.0 mm |
Measuring rods |
p = 4.0 mm |
a = 0.2 ... 1.0 mm |
Cable Assignment
*) +VS = 10 ... 28 V DC with ATEX certification
+VS = 10 ... 30 V DC without ATEX certification
Dimension Drawing
Assembly Drawing for Wheel Targets
Assembly drawing for scanning measuring rods
Safety Information
The following information must be observed when using sensors of type GEL 2478_Z with ATEX certificate in explosion-hazardous areas.
The maximum electrical and mechanical limiting values given in the technical data may not be exceeded. The following safety parameters apply to the GEL 2478 sensor:
The rail sensor may be operated only within the specified operational temperature range, namely -40°C.. .+ 85°C. The cables between the power inlet and the GEL 2478 sensor and between the sensor and the external evaluation unit may not exceed the specified maximum length. Connection and installation of the safety barriers may be carried out only by certificated personnel; installation of modules relevant to explosion hazards may be carried out only by authorised expert technicians. The cables and housing of the GEL 2478 sensor must be undamaged: in the event that these elements are damaged then the unit may not be installed.
Type-examination:
EC type-examination certificate BVS 07 ATEX E 030 for sensor type GEL 2478_Z dated 09.03.2007. The certificate is available on request.
Description of a protective circuit as shown in the example drawing below
The power supply is connected to the 9002/13-280-110-001 safety barrier. This safety barrier limits the current flowing in the EEX circuit to at most 119 mA and the voltage to at most 28 V. The output signals from the GEL 2478 sensor are connected to the 9002/11-120-024-001 safety barrier. In the event of a malfunction, this barrier limits the current to at most 12 mA and the voltage to at most 12 V. The 9002/11-120-024-001 safety barrier routes each of the output signals to a DEK 0E 5DC/ 24CD/1 00 kHz optocoupler. These optocouplers serve to convert the output signals back to a range that can be evaluated by the SPS.
Summary of the resource parameters
Optocoupler:
DEK 0E 5DC/24DC/100 kHz; article no.: 29 64 27 0
Supplier: Phoenix Contact GmbH & Co.KG; Blomberg
Example of protective circuitry
The following diagram shows one possible protective circuit for the GEL 2478 sensor using safety barriers. The safety barriers and optocouplers are not supplied with the GEL 2478 sensor.
Model/ Type code
Lenord & Bauer: Rail Speed Sensors & Rotary Pulse Encoder
Other products relating to GEL 2478 are:
GEL 247,
GEL 248,
GEL 2471,
GEL 24724,
GEL 2474,
GEL 2477