Transducer điện trở nhiệt Phoenix Contact MINI MCR-2-RTD-UI-C - 2902048

Transducer điện trở nhiệt Phoenix Contact MINI MCR-2-RTD-UI-C - 2902048

276
Nhà sản xuất: Phoenix Contact;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Transducer điện trở nhiệt Phoenix Contact MINI MCR-2-RTD-UI-C - 2902048

 

Product Description

Configurable, 3-way isolated temperature transducer with plug-in connection technology. The device is suitable for the connection of resistance thermometers and remote resistance-type sensors with 2, 3, and 4-conductor connection technology. The measured values are converted into a linear and freely adjustable current or voltage signal. You can configure the device using one of the free software solutions. Default settings can also be made directly on the device by simply using the DIP switches (see configuration table). The measuring transducer supports fault monitoring and NFC communication.

 

Technical Data

Notes

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
 

Product properties

Product type Temperature transmitter
Product family MINI Analog Pro
Type Signal conditioner
Configuration DIP switches
Software
App
Insulation characteristics
Overvoltage category II
Pollution degree 2
 

Electrical properties

Electrical isolation 3-way isolation
Protective circuit Transient protection
Step response (0–99%) 200 ms (2-conductor)
500 ms (3-conductor)
500 ms (4-conductor)
Maximum temperature coefficient 0.01 %/K
Transmission error resistance-type sensor 2 Ω
Transmission error resistance thermometer 0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni)
0.3 % * 200 K / set measuring range; 0.3 % > 200 K (Cu)
Electrical isolation Input/output/power supply
Rated insulation voltage 300 Vrms
Test voltage 3 kV AC (50 Hz, 60 s)
Insulation Reinforced insulation according to IEC/EN 61010-1
Supply
Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption 32 mA (24 V DC)
63 mA (12 V DC)
Power consumption ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
 

Input data

Signal
Number of inputs 1
Measurement
Number of inputs 1
Configurable/programmable Yes
Sensor types (RTD) that can be used Pt, Ni, Cu sensors
Temperature measuring range -200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
Temperature measuring range ≥ 20 K
Sensor input current approx. 200 µA
Max. permissible overall conductor resistance ≤ 25 Ω (Per line, RTD in 3- or 4-conductor technology)
≤ 50 Ω (adjustable, RTD in 2-conductor technology)
Linear resistance measuring range 0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
Connection technology 2-, 3-, 4-conductor
 

Output data

Signal: Voltage/current
Number of outputs 1
Configurable/programmable Yes
Voltage output signal 0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10 V (via DIP switch)
10 V ... 0 V (via DIP switch)
0 V ... 10.5 V (can be set via software)
Max. voltage output signal approx. 12.3 V
Non-load voltage < 17.5 V
Current output signal 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
20 mA ... 0 mA (via DIP switch)
20 mA ... 4 mA (via DIP switch)
0 mA ... 21 mA (can be set via software)
Max. current output signal 24.6 mA
Short-circuit current < 31.5 mA
Load/output load voltage output ≥ 10 kΩ
Load/output load current output ≤ 600 Ω (at 20 mA)
Ripple < 10 mVrms
< 10 mVrms (at 600 Ω)
Resolution, outputs (voltage) 1 mV
Resolution, outputs (current) 2 µA
Behavior in the event of a sensor error configurable
 

Connection data

Connection method Screw connection
Stripping length 10 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 1.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12 (flexible)
Tightening torque 0.5 Nm ... 0.6 Nm
 

Ex data

Ex installation (EPL) Gc
Div. 2
 

Interfaces

Data: IFS interface
Connection method Micro USB type B
 

Signaling

Status display Green LED (supply voltage)
Error indication Red LED
 

Dimensions

Width 6.2 mm
Height 109.81 mm
Depth 119.2 mm
 

Material specifications

Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
Housing material PBT
 

Environmental and real-life conditions

Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude ≤ 2000 m
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
 

Approvals

CE
Certificate CE-compliant
ATEX
Identification  II 3 G Ex ec IIC T4 Gc
Certificate BVS 20 ATEX E 024 X
UKCA Ex (UKEX)
Identification  II 3 G Ex ec IIC T4 Gc
Certificate PxCIF21UKEX2902049X
IECEx
Identification Ex ec IIC T4 Gc
Certificate IECEx BVS 20.0017X
UL, USA/Canada
Identification UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Shipbuilding approval
Certificate DNV GL TAA00002UA
EAC Ex
Identification  2Ex ec IIC T4 Gc
Certificate BY/112 02.01 TP012 103.01 00079
DNV GL data
Temperature B
Humidity B
Vibration A
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board
 

EMC data

Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Comments Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 0.06 %
Fast transients (burst)
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 0.1 %
Surge current load (surge)
Standards/regulations EN 61000-4-5
Conducted interference
Designation Conducted interferences
Standards/regulations EN 61000-4-6
Typical deviation from the measuring range final value 0.07 %
 

Standards and regulations

Electrical isolation 3-way isolation
 

Mounting

Mounting type DIN rail mounting
Assembly instructions The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting position any
 

Commercial Data

Item number 2902048
Packing unit 1 pc
Minimum order quantity 1 pc
Note Made to Order (non-returnable)
Sales Key CK1421
Product Key CK1421
Catalog Page Page 82 (C-5-2019)
Weight per Piece (including packing) 126.5 g
Weight per Piece (excluding packing) 110 g
Customs tariff number 85437090
Country of origin DE
 

Classifications

ECLASS

ECLASS-11.0 27210129
ECLASS-12.0 27210129
ECLASS-13.0 27210129
 

ETIM

ETIM 8.0 EC002919
 

UNSPSC

UNSPSC 21.0 41112100
 

Approvals

DNV GL

Approval ID: TAA00002UA

L Listed

Approval ID: FILE E 238705

cUL Listed

Approval ID: FILE E 238705

IECEx

Approval ID: IECEx_BVS_20.0017X

cUL Listed

Approval ID: FILE E 196811

UL Listed

Approval ID: FILE E 196811

ATEX

Approval ID: BVS 20 ATEX E 024 X
 

Environmental Product Compliance

 
REACh SVHC Lead 7439-92-1
 
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”
 

Compatible Products

Accessories

 All  Adapter  Communication module  Connector set  DIN rail bus connectors  Marker for end clamp  Marker strip  Module carrier  Monitoring module  Plastic label  Power supply unit  Power terminal block  Programming adapter  System adapter 

Product type
TC-D37SUB-AIO16-MP-PS-UNI - 2906640
Module carrier
TC-D37SUB-ADIO16-MP-P-UNI - 2906639
Module carrier
ME 6,2 TBUS-2 1,5/5-ST-3,81 GY - 2695439
DIN rail bus connectors
QUINT4-SYS-PS/1AC/24DC/2.5/SC - 2904614
Power supply unit
ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728
DIN rail bus connectors
MINI MCR-2-PTB - 2902066
Power terminal block
MINI MCR-2-PTB-PT - 2902067
Power terminal block
MINI MCR-2-FM-RC - 2904504
Monitoring module
MINI MCR-2-FM-RC-PT - 2904508
Monitoring module
MINI MCR-2-V8-FLK 16 - 2901993
System adapter
MINI MCR-2-V8-MOD-RTU - 2905634
Communication module
MINI MCR-2-V8-MOD-TCP - 2905635
Communication module
MINI MCR-2-V8-PB-DP - 2905636
Communication module
MINI MCR-2-V8-PN - 2905637
Communication module
IFS-USB-PROG-ADAPTER - 2811271
Programming adapter
IFS-BT-PROG-ADAPTER - 2905872
Adapter
TWN4 MIFARE NFC USB ADAPTER - 2909681
Programming adapter
FASTCON PRO-SET - 2906227
Connector set
FASTCON PRO-SET-PT - 2906228
Connector set
UCT-EM (30X5) - 0801505
Marker for end clamp
UCT-EM (30X5) CUS - 0801589
Marker for end clamp
SK 5,0 WH:REEL - 0805221
Marker strip
UC-EMLP (15X5) - 0819301
Plastic label
UC-EMLP (15X5) YE - 0822615
Plastic label
UC-EMLP (15X5) CUS - 0824550
Plastic label
UC-EMLP (15X5) YE CUS - 0824551
Plastic label
UC-EMLP (15X5) SR - 0828095
Plastic label
UC-EMLP (15X5) SR CUS - 0828099
Plastic label
US-EMLP (15X5) - 0828790
Plastic label
US-EMLP (15X5) YE - 0828873
Plastic label
US-EMLP (15X5) SR - 0828874
Plastic label
US-EMLP (15X5) CUS - 0830076
Plastic label
US-EMLP (15X5) YE CUS - 0830077
Plastic label
US-EMLP (15X5) SR CUS - 0830078
Plastic label
UCT-EM (30X5) YE - 0830340
Marker for end clamp
UCT-EM (30X5) YE CUS - 0830348
Marker for end clamp
SẢN PHẨM XEM NHIỀU
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại