Smart measurement Sensor & Controller Omron OMRON ZX-GT28R + ZX-GT28E11 & ZX-GTC11

 
Output type NPN
Appearance Separate type
Light source Visible semiconductor laser diode (wavelength 650 nm, CLASS 1 of EN60825-1/
IEC60825-1, CLASS II of FDA (21CFR 1040.10 and 1040.11)
Measuring width 28 mm
Sensing distance 0 to 500 mm
Minimum sensing object 0.5 mm dia. *1
Linearity ±0.1%F.S. *2
Resolution 10 μm (number of process values to average: 16) *3
Temperature 0.01%F.S/°C *4
characteristic  
Indicators (emitter) Laser ON indicator (green), laser alarm indicator (red)
Indicators (receiver) Optical axis setting indicator (green)
Laser OFF input/sync ON: Short-circuited with 0 V or 1.5 V max.
input OFF: Open (leakage current: 0.1 mA max.)
   
Laser deterioration NPN open-collector output
alarm output 30 VDC 20 mA max.
  Residual voltage 1.2 V max.
Power consumption 30 mA max.
(emitter)  
Power supply voltage 24 VDC +10%, -15% ripple (p-p) 10% max.
(emitter)  
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Insulation resistance 20 MΩ (at 500 VDC)
Operating ambient 3,000 lx (incandescent light)
illumination (emitter)  
Operating ambient 1,000 lx (incandescent light) *5
illumination (receiver)  
Ambient temperature Operating: 0 to 40°C Storage: -15 to 50°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Vibration resistance 10 to 150 Hz Single-amplitude: 0.75 mm for 80 min each in X, Y and Z directions
(durability)  
Shock resistance 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
(durability)  
Degree of protection IEC60529 IP40
Cable length 2 m
Material Case: aluminum die-cast, Lens: glass
Weight (packed state) Approx. 550 g
Accessories Laser warning labels, Instruction Sheet

F.S.: 28 mm measuring range of receiver
*1. Distance between emitter and receiver: 500 mm, measurement object at 250 mm from receiver.
       Glass ends of chamfer 0.1 mm or more can be detected in glass edge measurement mode. (at binary level 70%)
*2. Linearity is given to be a typical error with respect to an ideal straight line when the distance between the emitter
       and receiver is 100 mm and light is blocked at a distance of 50 mm from the receiver.
       (On the ZX-GT2840[][], the measurement object is measured at a distance of 20 mm from the receiver.)
*3. The amount of fluctuation (±3σ) in the analog output when the distance between the emitter and receiver is 100 mm
       and a ZX-GTC[][] is connected
*4. Change in the light cutoff value on one side when the distance between the emitter and receiver is 100 mm and the
       light is half-cutoff at a distance of 50 mm from the receiver
       (On the ZX-GT2840[][], the measurement object is measured at a distance of 20 mm from the receiver.)
*5. Standard mode (NORM) used
 

Controller

Model

ZX-GTC11

Output type NPN
Measurement cycle *1 1.5 ms (standard mode (NORM)) 0.5 ms (high-speed mode (FAST)) *2
Samples to average 1/2/4/8/16/32/64/128/256/512/1,024/2,048/4,096
Analog output *3 For current output: 4 to 20 mA/F.S., max. load resistance 300 Ω For voltage output:
±4 V, (±5 V, 1 to 5 V *4), output impedance 100 Ω
Timing input, bank switching ON: short-circuited with 0 V or 1.5 V max.
input, zero reset input, OFF: Open (leakage current: 0.1 mA max.)
reset input  
HIGH/PASS/LOW Judgment NPN open-collector output
output *5 Sync output *6 30 VDC 50 mA max.
  Residual voltage 1.2 V max.
Indicator Judgment output indicator: HIGH (orange), PASS (green), LOW (orange)
Main display (red) Sub-display (yellow) Bank 1/2 (orange), zero reset (green)
Main Number of 2 banks
functions registered setups  
  Measurement Interrupted beam width measurement, incident beam width measurement, outer
  Mode diameter measurement, center position measurement, IC lead pitch, IC lead width
    judgment, specified edge measurement, wire position measurement, glass edge
    position measurement
  Display during Measured value, resolution, threshold, voltage output value, current output value
  measurement (number of display digits can be changed)
  Zero reset Offset setting of zero reset value, zero reset value memory
  functions  
  Hold Sample hold, peak hold, bottom hold, peak-to-peak hold, average hold, delay hold
  Timer functions ON delay, OFF delay, one-shot
  Adjustment Optical Axis adjust mode/light intensityt writing mode, variable binary level, variable
  functions edge filter, analog output scaling
  Calculation 2 Possible on up to two Controllers (Calculation Unit ZX-CAL2 is required for
  connecting Controllers to each other.) A-B, A+B, width
  Other Measurement cycle setting, threshold setting, hysteresis setting, initialization, key lock
Temperature characteristic 0.005%F.S./°C
Current consumption 150 mA max. with power supply voltage of 24 VDC (including receiver) *7
Power supply voltage 24 VDC +10%, .15% ripple (p-p) 10% max.
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Insulation resistance 20 MΩ (at 500 VDC)
Ambient temperature Operating: 0 to 50°C Storage: .15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Vibration resistance 10 to 150 Hz Single-amplitude: 0.35 mm for 80 min each in X, Y and Z directions
(durability)  
Shock resistance (durability) 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Degree of protection IEC60529 IP20
Cable length 2 m
Material Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Weight (packed state) Approx. 330 g
Accessories Instruction Sheet

*1. A simple average is used in IC lead pitch judgment mode or IC lead width judgment mode.
       The measurement cycle time can be calculated as follows: Specified measurement cycle time × (Number of samples
       to average + 1) + 1 ms max.
       In other measurement modes, a moving average is used. The first measurement cycle time can be calculated as
       follows: Specified measurement cycle time × (Number of samples to average + 1) + 1 ms max. The second and
       later measurement cycle times will be equal to the specified measurement cycle time.
*2. The response time in the high-speed mode (FAST) for the IC lead pitch and IC lead width judgment modes is 1 ms.
*3. Current/voltage can be switched using the switch provided on the rear of the Controller.
*4. Can be set by the analog output scaling function.
*5. The error (ERR) state is displayed when all HIGH/PASS/LOW outputs turn OFF.
*6. Normally, wire the sync output wire directly to the emitter’s sync input wire and run the Controller in the standard
       mode. On an NPN type Controller, use an NPN type emitter, and on a PNP type Controller, use a PNP type emitter.
       Wiring of the sync wires is not required when the Controller is run in the high-speed mode.
       (Note, however, that the Controller becomes more susceptible to the influence of ambient light in this case.)
*7. The value is 175 mA max. (including receiver) when current output is set.
 

Interface Unit

Model

ZX-GIF11/-GIF11A

Compatible Controller ZX-GTC11
Indicator Power ON (green), Controller communications (orange), Controller
communications error (red), RS-232C communications (orange), RS-232C
communications error (red), binary output (orange)
Communications port RS-232C (9-pin D-sub connector)
12-bit binary output NPN open-collector output
(D11 to D0, GATE) 30 VDC 20mA max.
  Residual voltage 1.2 V max.
Power supply voltage Supplied from Controller (power consumption: 60 mA max.)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Insulation resistance 20 MΩ (at 500 VDC)
Ambient temperature Operating: 0 to 50°C Storage: .15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Vibration resistance (durability) 10 to 150 Hz Single-amplitude: 0.35 mm for 80 min each in X, Y and Z directions
Shock resistance (durability) 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Degree of protection IEC60529 IP20
Cable length RS-232C 0.5 m, binary output 2 m
Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Weight (packed state) ZX-GIF[]1A: Approx. 550 g
ZX-GIF[]1: Approx. 330 g
Accessories ZX-GIF[]1A: Setup Software (CD-ROM), 2 clamps, Instruction Sheet
ZX-GIF[]1: 2 clamps, Instruction Sheet

 