| Its | Model | Description | Q'ty |
| 1 | 3WL1212-2EB36-4GA2-ZF02+F05 | withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=1250A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion | 1 |
| 2 | 3WL1220-2EB36-4GA2-ZF02+F05 | withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion | 1 |
| 3 | 3WL1220-2EB46-4GA2-ZF02+F05+S08 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 | 1 |
| 4 | 3WL1220-2EB46-4GA2-ZF02+F05+R15+S08 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 | 1 |
| 5 | 3WL1220-2EB46-4GA2-ZF02+F05 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion | 1 |
| 6 | 3WL1220-2EB46-4GA2-ZF02+F05+R15 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts | 1 |
| 7 | 3WL1225-2EB36-4GA2-ZF02+F05 | withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion | 1 |
| 8 | 3WL1225-2EB46-4GA2-ZF02+F05+S08 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 | 1 |
| 9 | 3WL1225-2EB46-4GA2-ZF02+F05 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion | 1 |
| 10 | 3WL1225-2EB46-4GA2-ZF02+F05+R15 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts | 1 |
| 11 | 3WL1240-2EB47-4GA2-ZF02+F05+R15 | withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts | 1 |