Its |
Model |
Description |
Q'ty |
1 |
3WL1212-2EB36-4GA2-ZF02+F05 |
withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=1250A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion |
1 |
2 |
3WL1220-2EB36-4GA2-ZF02+F05 |
withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion |
1 |
3 |
3WL1220-2EB46-4GA2-ZF02+F05+S08 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 |
1 |
4 |
3WL1220-2EB46-4GA2-ZF02+F05+R15+S08 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 |
1 |
5 |
3WL1220-2EB46-4GA2-ZF02+F05 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion |
1 |
6 |
3WL1220-2EB46-4GA2-ZF02+F05+R15 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts |
1 |
7 |
3WL1225-2EB36-4GA2-ZF02+F05 |
withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion |
1 |
8 |
3WL1225-2EB46-4GA2-ZF02+F05+S08 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion S08= RONIS locking device in Off position Disconnector condition Safe Off/disconnector function Safe Off function Disconnector condition in compliance with IEC 60947-2 |
1 |
9 |
3WL1225-2EB46-4GA2-ZF02+F05 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion |
1 |
10 |
3WL1225-2EB46-4GA2-ZF02+F05+R15 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts |
1 |
11 |
3WL1240-2EB47-4GA2-ZF02+F05+R15 |
withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=4000A to 690V, AC50/60Hz Icu=66kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC F02= COM15 PROFIBUS module with breaker status sensor F05= Measuring function plus for U, I, P, W Harmonics and total harmonic distortion R15= Position signaling switch, withdrawable part 3 changeover contacts |
1 |