Product code | SS 20.600 |
Sensor type | Insertion sensor |
Tube diameter | DN 25 bis DN 800 |
Max. volume flow m³/h | 500.000 (DN 800) |
Max. pressure | 40 bar |
Display | 4-point LED or external |
LED-display (SS 20.031) | |
Working temperature | -20 … +120 °C |
Output signals | Auto-U/I (automatic switch V↔ I) impulse output optional |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.261 |
Sensor type | Insertion sensor |
Tube diameter | DN 25 – DN 600 |
Max. volume flow m³/h | 74.300 (DN 700) |
Max. pressure | 10 bar |
Display | 1 green LED, |
1 red LED | |
Working temperature | -20 … +85 °C |
Output signals | 4 … 20 mA |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 30.300 … 30.303 |
Sensor type | Inline-Sensor |
Tube diameter | with integrated probe tube |
DN 15 / 25 / 40 / 50 | |
Max. volume flow m³/h | 75 / 228 / 417 / 712 |
Max. pressure | 16 bar |
Display | Integrated LED-display |
Working temperature | 0 … +60 °C |
Output signals | 1 x 4 … 20 mA or switching output |
1 x switch-/Impulse output | |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.200 |
sensor head | dumb-bell head |
Measuring range | 0.06 … 20 m/s |
Medium temperature | -20 … +85 °C |
Temperature measurement | – |
Medium | clean or dusty gases gase |
Aggressive Media | yes, optional coating |
ATEX | no |
Max. pressure | 10 bar |
Output signals | switching output (flow monitor, galvanic separated) |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.260 |
sensor head | chamber head |
Measuring range | 0.2 … 50 m/s |
Medium temperature | -20 … +85 / 120 °C |
Temperature measurement | yes (optional) |
Medium | relatively clean gases (not aggressive) |
Aggressive Media | no |
ATEX | no |
Max. pressure | atmosph. |
Output signals | 0 ... 10 V or |
4 ... 20 mA | |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.261 |
sensor head | chamber head |
Measuring range | 0.2 … 90 m/s |
Medium temperature | -20 … +85 °C |
Temperature measurement | yes |
Medium | relatively clean gases (not aggressive) |
Aggressive Media | no |
ATEX | no |
Max. pressure | 10 bar |
Output signals | 4 ... 20 mA |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.500 |
sensor head | dumb-bell head |
Measuring range | 0.06 … 50 m/s |
Medium temperature | -40 … 85 °C |
Temperature measurement | yes |
Medium | clean or dusty gases gase |
Aggressive Media | yes, optional coating |
ATEX | Option |
(cat. 3GD, zone 2) | |
Max. pressure | 10 bar |
Output signals | Auto-U/I |
(automatic switch V↔ I) | |
Supply voltage | 24 V AC/DC ± 20 % |
Product code | SS 20.600 |
sensor head | chamber head |
Measuring range | 0,2 … 220 m/s |
Medium temperature | -20 … +120 °C |
Temperature measurement | yes |
Medium | relatively clean gases (also burnable gases) |
Aggressive Media | no |
ATEX | Option |
(cat. 3GD, zone 2) | |
Max. pressure | 40 bar |
Output signals | Auto-U/I (automatic switch V↔ I) impuls output (optional) |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.650 |
sensor head | chamber head |
Measuring range | 0.2 … 60 m/s |
Medium temperature | 0 … +200 / 350 °C |
Temperature measurement | yes |
Medium | relatively clean gases (not aggressive) |
Aggressive Media | no |
ATEX | no |
Max. pressure | 16 bar (optional) |
Output signals | 0 ... 10 V or |
4 ... 20 mA, Impulse | |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 23.400 |
sensor head | thermopile head |
Measuring range | 0.05 … 20 m/s |
Medium temperature | 0 … 60 °C |
Temperature measurement | – |
Medium | clean gases (not aggressive) |
Aggressive Media | no |
ATEX | yes |
(cat. 3G, zone 2) | |
Max. pressure | atmosph. |
Output signals | 0 ... 10 V or |
4 ... 20 mA, 2 x switching output (OC) | |
Supply voltage | 7.5/12 ... 26.4 V DC |
Product code | SS 20.250 |
Application | Filter monitoring, supply and exhaust control |
Sensor head | Dumb-bell head |
Measuring range | 0,06 … 20 m/s |
Medium temperature | -20 ... +70 °C |
Moistness area | 0 ... 95 % rF |
Specials | SS 20.515 for disinfection with |
H2O2 (VHP) | |
Mounting | Mounting lengths from 300 / 500 mm available |
Output signals | Auto UI |
4 … 20 mA ↔ | |
0 … 10 V |
Product code | SS 20.515 |
Application | Filter monitoring, Room monitoring |
Sensor head | Dumb-bell head |
Measuring range | 0,06 … 10 m/s |
Medium temperature | 0 ... +60 °C |
Moistness area | 0 ... 95 % rF |
Specials | SS 20.515 for disinfection with |
H2O2 (VHP) | |
SS 20.516 for disinfection with alcohol (with coating) | |
Mounting | Screwed bush |
M25 (stainless steel) | |
Quick mounting system | |
- Counternut | |
- Screw adapter | |
- Shank nut | |
- Flange bushing | |
Output signals | 0 ... 10 V |
4 ... 20 mA |
Product code | SS 20.400 / SS 23.400 |
Application | Flow direction (turbulence degree) |
Sensor head | Thermopile head |
Measuring range | 0,05 … 20 m/s |
Medium temperature | 0 … +60 °C |
Moistness area | 0 ... 95 % rF |
Specials | Bi-directional flow sensor |
Switching outputs | |
Measurement of turbulence degree | |
Self monitoring function | |
Detection of contamination ATEX version for Ex-secured areas | |
Mounting | Easy one-hole-mounting |
Output signals | 0 ... 10 V |
4 ... 20 mA |
Product code | SS 20.415 |
Application | Flow direction (turbulence degree) |
Sensor head | Thermopile head |
Measuring range | 0,05 … 20 m/s |
Medium temperature | 0 … +60 °C |
Moistness area | 0 ... 95 % rF |
Specials | Disinfection with H2O2 and alcohols |
Bi-directional flow sensor | |
Switching outputs | |
Measurement of turbulence degree | |
Self monitoring function Detection of contamination | |
Mounting | Screwed bush |
M25 (stainless steel) | |
Quick mounting system | |
- Counternut | |
- Screw adapter | |
- Shank nut | |
- Flange bushing | |
Output signals | 0 ... 10 V |
4 ... 20 mA |
Product code | SS 20.500 |
Application | Filter monitoring, Room monitoring if corrosive medias are present |
Sensor head | Dumb-bell head |
Measuring range | 0,06 … 50 m/s |
Medium temperature | -20 … +85 °C |
Moistness area | 0 ... 95 % rF |
Specials | Disinfection with H2O2 and alcohols |
Protection against corrosion e.g.: | |
- hydrochloric acid | |
- caustic soda | |
- acetone | |
High precision adjustment | |
Mounting | Mounting lengths from 100 to 1.000 mm available |
Output signals | Auto UI |
0 … 10 V | |
4 … 20 mA ↔ |
Product code | SS 20.200 |
Sensor head | Dumb-bell head |
Measuring range | 0,06 … 20 m/s |
Mediumstemperatur | -20 ... +85 °C |
Temperaturmessung | — |
Medium | Clean or dusty air |
Tube diameter | 100 ... 1.000 mm |
Aggressive air content | yes, option with coating |
Output signals | Switching output (flow monitor) |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.250 |
Sensor head | Dumb-bell head |
Measuring range | 0,06 … 20 m/s |
Mediumstemperatur | -20 ... +70 °C |
Temperaturmessung | — |
Medium | Clean or dusty air |
Tube diameter | 100 ... 1.000 mm |
Aggressive air content | yes, option with coating |
Output signals | Auto- U/I (automatic switch V↔ I) |
Supply voltage | 24 V AC/DC ± 20 % |
Product code | SS 20.260 |
Sensor head | Chamber head |
Measuring range | 0,2 … 50 m/s |
Mediumstemperatur | -20 ... +120 °C |
Temperaturmessung | yes (option) |
Medium | Relatively clean air |
Tube diameter | 25 ... 1.000 mm |
Aggressive air content | — |
Output signals | 0 ... 10 V or |
4 … 20 mA | |
Supply voltage | 24 V DC ± 20 % |
Product code | SS 20.500 |
Sensor head | Dumb-bell head |
Measuring range | 0,06 … 50 m/s |
Mediumstemperatur | -40 ... +85 °C |
Temperaturmessung | yes |
Medium | Clean or dusty air |
Tube diameter | 100 ... 2.000 mm |
Aggressive air content | yes, option with coating |
Output signals | Auto- U/I (automatic switch V↔ I) |
Supply voltage | 24 V AC/DC ± 20 % |