Valves based on ATEX 1,000–10,000 bar
Hand valves, metering valves 1,000–10,000 bar
Micrometering valves 1,000–7,000 bar
Piston type air-operated valves 1,000–7,000 bar
Diaphragm type air-operated valves 400–10,000 bar
High-temperature valves 1,000–4,000 bar
Special valves max. 2000 bar
Laboratory valves LHP 1,000 bar
Motor-driven valves 1,000–7,000 bar
Air-operated control valves max. 4,000 bar
Test bench valves max. 90°C -0.8–+40 bar
Test bench valves max. -40–+120°C max. 500 bar
Test bench valves max. -40–+120°C max. 300 bar
Fittings
HP Connectors 1,000–10,000 bar
Standard fittings 1,000–10,000 bar
Special fittings, reducers, adapters max. 7,000 bar
Swivel joints 1,500–4,000 bar
Check valves 2,000–10,000 bar
Safety heads 10–7,000 bar
Safety relief valves 500–4,400 bar
Relief valves 4,000 bar
Filters 1,000–7,000 bar
Standard LHP fittings 2,000 bar
Tubing and hoses
High-pressure tubing 1,200–11,000 bar
High-pressure hoses 3,200 bar
Assembly instructions for LHP tubes (1/8" and 1/16")
Sizing of high-pressure tubing systems
Pressure vessels
Optical cells and windows units 100–7,000 bar
Optical cells for in-line monitoring 100–1,000 bar
Optical cells:
Reliable optical monitoring of chemical and physical characteristics of liquids, gases and solids at max. pressures from 100 up to 7,000 bar.SITEC-Sieber Engineering AG is authorized by TÜV to design and maunufacture pressure vessels according to PED category I and II.
Pressure generators
Hand pumps 300–7,000 bar
Motor-driven pumps 300–7,000 bar
Pressure intensifiers 7,000 bar, 10,000 bar
Air driven diaphragm type compressors 1,000 bar
Gear pumps max. 700 bar
Hand lever pumps 500–1,000 bar
Pilot units for supercritical fluid extraction (SFE) of solids
Selective separation of valuable thermolabile components from solid raw materials using a supercritical gas as solvent.
Standard designOptionsMax. operating pressure300 bar 500, 700 bar
Max. operating temperature 80°C120, 150, 200°C
CO2 flow capacity 18 l/h10, 30, 50, 100 l/h
Extractor capacity 1 litre2, 4, 6, 10, 20 litres
Multi-purpose pilot units for supercritical fluid extraction (SFE) of liquids and solids
Selective separation of valuable thermolabile components from solid and liquid raw materials using a supercritical gas as solvent.
Standard designOptionsMax. operating pressure300 bar500, 700 bar
Max. operating temperature 80°C120, 150, 200°C
CO2 flow capacity 18 l/h 10, 30, 50, 100 l/h
Extractor capacity 1 Liter 2, 4, 6, 10, 20 litres
Column interior diameter Ø 38 mm Ø 50, 65, 90 mm
Column internal lenght 2 m 3, 4, 5 m
Liquid capacity 2 l/h 4, 10, 18 l/h
Phase equilibria apparatus
System for fast determination of solubility data and for the observation of phase behaviour at high-pressure conditions, as base for supercritical fluid extraction processes.
Standard designOptionsMax. operating pressure 500 bar 700, 1,000 bar
Max. operating temparature 80°C 120, 150, 200°C
Equilibria cell capacity 25 ml 50 ml
Pilot units for high-presssure micronization and spray drying (RESS/GAS)
High-pressure micronization (RESS/GAS) is used to generate very fine and uniform powders or well defined geometries of solid particles by expansion of a high-pressure fluid.
Standard designOptionsMax. operating pressure 300 bar 500 bar
Max. operating temparature 80°C 120, 150, 200°C
CO2 flow 18 l/h 10, 30, 50, 100 l/h
Column interior diameter Ø 90 mm Ø 60, 110, 160 mm
Column internal lenght 1 m 0.4, 2 m
Pilot units for continuous supercritical fluid reactions
Performing a reaction at supercritical conditions enhances the conversion rates and the space-time yield. Smaller reactors can be used for the same amount of reaction product.
Standard design OptionsMax. operating pressure 50–1,000 bar
Max. operating temparature 20–500°C
Pilot units for high-pressure sterilization
Applying ultra-high-pressure to pharmaceutical or natural products leads to an inactivation of germs without thermal alteration of the products.
Standard designOptionsMax. operating pressure 7,000 bar 10,000 bar
Max. operating temparature 80°C 120°C
Sterilization autoclave 70 ml 100 ml
Units for high-pressure autofrettage
Treatment of high-pressure components (e.g. fuel-injection tubings) to increase the fatigue limit under cycling pressures.
Standard designOptionsMax. operating pressure 7,000 bar 10,000 bar
Stroke capacity of intensifier 18 ml 45 ml
Ultra-high-pressure generation systems
Systems for the generation of very high pressures (up to 10,000 bar / liquids or gases) based on hand pumps, electrical piston pumps or intensifiers.
Standard designOptionsMax. operating pressure 7,000 bar 10,000 bar
Stroke capacity of intensifier 18 ml 45 ml
Retrofit of existing pilot units
Modular design allows technical upgrading and extension of existing high-pressure pilot units.
Picture shows pilot unit for the extraction of caffeine from coffee beans (right part) which was adapted for the treatment of tea leaves with water saturated carbon dioxide (left part).
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
Sensors In Agriculture (Comming soon)Sensors In Agriculture. Soil moisture sensors, Agricultural temperature sensors, GPS sensors, Weather sensors, Crop health sensors, Electronic sensors, Light
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu