Bộ điều khiển mức siêu âm Siemens 7ML5050-0AA11-1DA0

Bộ điều khiển mức siêu âm Siemens 7ML5050-0AA11-1DA0

793
Nhà sản xuất:

Siemens

;   

Xuất xứ: Germany

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Bộ điều khiển mức siêu âm Siemens 7ML5050-0AA11-1DA0

 
Product
Article Number (Market Facing Number) 7ML5050-0AA11-1DA0
Product Description SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC -
Product family SITRANS LUT400 series
Product Lifecycle (PLM) PM300:Active Product
Price data
Price Group / Headquarter Price Group 8L1
List Price Show prices
Customer Price Show prices
Metal Factor None
Delivery information
Export Control Regulations ECCN : EAR99 / AL : N
Standard lead time ex-works 1 Day/Days
Net Weight (kg) 3.000 Kg
Packaging Dimension 291000.00 x 328000.00 x 236000.00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN 4019169846868
UPC Not available
Commodity Code 90261029
LKZ_FDB/ CatalogID FI01-4
Product Group 4719
Group Code R3P5
Country of origin Canada
Compliance with the substance restrictions according to RoHS directive Since: 10/01/03
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
Reach Information
Classifications
 
  Version Classification
eClass 12 27-20-05-17
eClass 9 27-20-05-17
eClass 9.1 27-20-05-17
 

Tham khảo thêm các model khác cùng loại:

7ML5050-0AA12-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AA22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AB22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML1830-1PE

SITRANS LUT400 Lid (with Display)
 

7ML1830-1PA

SITRANS LUT400 Panel mount retrofit kit (convert standard unit with display to panel mount version)
 

7ML5050-0AA11-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CA12-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0BA12-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CA21-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AA21-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0BA11-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AB12-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CB11-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AA12-1DC0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0BA22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML1830-1PK

SITRANS LUT400 Panel mount gasket and fastener kit
 

7ML1930-1GF

SITRANS LUT400 Panel mount cable extension, 2.5 m (8.2 ft)
 

7ML5050-0AA12-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AA21-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AA21-1DC0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
7ML5050-0AB11-1DA0
SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AB21-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AA11-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AA12-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AA21-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB12-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AB12-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC11-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC12-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0BA11-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT430 - Level, Pump & Flow controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AC21-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AC22-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0BA21-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0BB21-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CA12-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT440 - High accuracy Open Channel Monitor Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0CA12-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT440 - High accuracy Open Channel Monitor Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB21-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC21-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AC21-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0BB22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CA11-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CB12-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AA11-1DC0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AA12-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0BA21-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT430 - Level, Pump & Flow controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0CA11-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT440 - High accuracy Open Channel Monitor Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AA11-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AA22-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AB22-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC11-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AC11-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC22-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0BA12-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT430 - Level, Pump & Flow controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0CA21-1DC0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AB22-1DC0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AC11-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AC12-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC21-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0BB11-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
7ML5050-0BB12-1DA0
SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CA22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0CB22-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AA22-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB11-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AB11-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB12-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB22-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AB22-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC12-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AC22-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0BA12-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT430 - Level, Pump & Flow controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0CB12-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT440 - High accuracy Open Channel Monitor Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AA11-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AA21-1DA0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML5050-0AA22-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB11-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AB21-1DA0

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

7ML5050-0AB21-1DA0-Z C11+Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With remote panel mount display Input Voltage: 10 to 32 V DC Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0AC12-1DA0-Z Y15

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: No display (blank lid provided) Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Stainless steel tag: (69 x 50 mm (2.71 x 1.97")): Measuring-point number/ identification (max.27 char acters)specify in plain text
 

7ML5050-0BB11-1DC0-Z C11

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT430 - Level, Pump & Flow controller Enclosure Display Options: With remote panel mount display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Hazardous locations CSA Class I, II, III Division 2 (Groups A,B,C,D,F,G) - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
 

7ML1830-1PB

SITRANS LUT400 Terminal block replacement kit (5 piece kit with one of each removable terminal)
 

7ML1830-1PC

SITRANS LUT400 Plate, Wall/Pipe Mount
 

7ML1830-1PD

SITRANS LUT400 Enclosure (include blank label)
 

7ML1830-1PF

SITRANS LUT400 Blank lid (no display)
 

7ML1830-1PG

SITRANS LUT400 AC Fuse (0.25 A, 250 V, Slow,Blow)
 

7ML1830-1PH

SITRANS LUT400 DC Fuse (1.6 A, 125 V, Slow,Blow)
 

7ML1830-1PL

SITRANS LUT400 DIN Rail Clip
 

7ML1930-1GE

KIT, SITRANS LUT400 SUN SHIELD KIT, 304 STAINLESS STEEL
 

7ML5050-.....-....

SITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging.
 

A5E33329501

Manual, SITRANS LUT400, English
 

A5E42824483

LUT420,ASSY,DC BOARDSTACK w/CRADLE,GP Spare electronics assembly In polycarbonate cradle for use in SITRANS LUT400 Model: LUT420 Level Controller Input Voltage: DC Approvals: General Purpose
 

A5E42824561

LUT420,ASSY,DC BOARDSTACK w/CRADLE,HAZ Spare electronics assembly In polycarbonate cradle for use in SITRANS LUT400 Model: LUT420 Level Controller Input Voltage: DC Approvals: Hazardous Locations
 

A5E42824562

LUT420,ASSY,AC BOARDSTACK w/CRADLE,GP Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT420 Level Controller Input Voltage: AC Approvals: General Purpose
 

A5E42824563

LUT420,ASSY,AC BOARDSTACK w/CRADLE,HAZ Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT420 Level Controller Input Voltage: AC Approvals: Hazardous Locations
 

A5E42824564

LLUT430,ASSY,DC BOARDSTACK w/CRADLE,GP Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT430 Level, Pump & Flow Controller Input Voltage: DC Approvals: General Purpose
 

A5E42824565

LUT430,ASSY,DC BOARDSTACK w/CRADLE,HAZ Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT430 Level, Pump & Flow Controller Input Voltage: DC Approvals: Hazardous Locations
 

A5E42824568

LUT430,ASSY,AC BOARDSTACK w/CRADLE,GP Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT430 Level, Pump & Flow Controller Input Voltage: AC Approvals: General Purpose
 

A5E42824570

LUT430,ASSY,AC BOARDSTACK w/CRADLE,HAZ Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT430 Level, Pump & Flow Controller Input Voltage: AC Approvals: Hazardous Locations
 

A5E42847453

LUT440,ASSY,DC BOARDSTACK w/CRADLE,GP Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT440 High accuracy Open Channel Monitor Input Voltage: DC Approvals: General Purpose
 

A5E42847454

LUT440,ASSY,DC BOARDSTACK w/CRADLE,HAZ Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT440 High accuracy Open Channel Monitor Input Voltage: DC Approvals: Hazardous Locations
 

A5E42847455

LUT440,ASSY,AC BOARDSTACK w/CRADLE,GP Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT440 High accuracy Open Channel Monitor Input Voltage: AC Approvals: General Purpose
 

A5E42847456

LUT440,ASSY,AC BOARDSTACK w/CRADLE,HAZ Spare electronics assembly in polycarbonate cradle for use in SITRANS LUT400 Model: LUT440 High accuracy Open Channel Monitor Input Voltage: AC Approvals: Hazardous Locations
Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Tụ chống sét Varistor (MOVs)là gì? Nguyên lý hoạt động (Wiki)Tụ chống sét ( Varistor hoặc Metal Varistor Oxit (MOV)) là một điện trở đặc biệt được sử dụng để bảo vệ mạch điện chống lại sự đột biến điện áp
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
Sensors In Agriculture (Comming soon)Sensors In Agriculture. Soil moisture sensors, Agricultural temperature sensors, GPS sensors, Weather sensors, Crop health sensors, Electronic sensors, Light
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại