Cảm biến quang điện | Photoelectric sensors | OMRON
Cảm biến quang điện | Photoelectric sensors | OMRON
Các models thuộc dòng cảm biến quang điện E3ZM-C của Omron | E3ZM-C Series Oil-resistant photoelectric sensor in compact stainless steel housing
Oil-resistant stainless steel housing, IP67 and IP69K for maximum water resistance, High visibility orange LED in through beam model for easy alignment; Shape Cuboid, Operation mode Dark-ON, Light-ON, Material housing Stainless steel, Thread size Other, Width 10.8 mm, Height 32 mm, Depth 21 mm, Power supply voltage 10-30 V, Features Oil-resistant, Degree of protection (IP) IP67/IP69K
E3ZM-C
Oil-resistant photoelectric sensor
in compact stainless steel housing
The oil-resistant compact photoelectric sensors in a robust stainless steel housing feature an enhanced functional reserve for reliable object detection in dirty and mechanically demanding environments such as automotive assembly lines.
Oil-resistant stainless steel housing
IP67 and IP69K for maximum water resistance
High visibility orange LED in through beam model for easy alignment
Common features
Shape Cuboid
Operation mode Dark-ON, Light-ON
Material housing Stainless steel
Thread size Other
Width 10.8 mm
Height 32 mm
Depth 21 mm
Power supply voltage 10-30 V
Features Oil-resistant
Degree of protection (IP) IP67/IP69K
Các models
Model E3ZM-CD62 2M Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD62 5M Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD62-M1TJ 0.3M Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD67 Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD82 2M Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD82 5M Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD82-M1TJ 0.3M Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CD87 Sensing method Diffuse reflective Sensing distance 1000 mm Sensing distance (min.)
Model E3ZM-CL61H 2M Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL61H 5M Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL61H-M1TJ 0.3M Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL62H 2M Sensing method Limited reflective Sensing distance 150 mm Sensing distance (min.) 10 mm
Model E3ZM-CL62H 5M Sensing method Limited reflective Sensing distance 150 mm Sensing distance (min.) 10 mm
Model E3ZM-CL62H-M1TJ 0.3M Sensing method Limited reflective Sensing distance 150 mm Sensing distance (min.) 10 mm
Model E3ZM-CL64H 2M Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL64H 5M Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL64H-M1TJ 0.3M Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL69H Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL81H 2M Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL81H 5M Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL81H-M1TJ 0.3M Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL82H 2M Sensing method Limited reflective Sensing distance 150 mm Sensing distance (min.) 10 mm
Model E3ZM-CL82H 5M Sensing method Limited reflective Sensing distance 150 mm Sensing distance (min.) 10 mm
Model E3ZM-CL82H-M1TJ 0.3M Sensing method Limited reflective Sensing distance 150 mm Sensing distance (min.) 10 mm
Model E3ZM-CL84H 2M Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL84H 5M Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL84H-M1TJ 0.3M Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CL86H Sensing method Limited reflective Sensing distance 100 mm Sensing distance (min.) 10 mm
Model E3ZM-CL89H Sensing method Limited reflective Sensing distance 200 mm Sensing distance (min.) 10 mm
Model E3ZM-CR61 2M Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR61 5M Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR61-M1TJ 0.3M Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR66 Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR81 2M Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR81 5M Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR81-M1TJ 0.3M Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CR86 Sensing method Retro-reflective Sensing distance 4000 mm Sensing distance (min.) 100 mm
Model E3ZM-CT61 2M Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT61 5M Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT61-M1TJ 0.3M Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT62B 2M Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT62B 5M Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT62B-M1TJ 0.3M Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT66 Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT67B Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT81 2M Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT81 5M Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT81-M1TJ 0.3M Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT82B 2M Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT82B 5M Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT82B-M1TJ 0.3M Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)
Model E3ZM-CT86 Sensing method Through-beam Sensing distance 15000 mm Sensing distance (min.)
Model E3ZM-CT87B Sensing method Through-beam Sensing distance 20000 mm Sensing distance (min.)