Cảm biến mức điện tử IFM LMT03A | LMDCE-A12E-QSKG-1/US/3D/3G

Cảm biến mức điện tử IFM LMT03A | LMDCE-A12E-QSKG-1/US/3D/3G

310
Nhà sản xuất: IFM;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Cảm biến mức điện tử IFM LMT03A | LMDCE-A12E-QSKG-1/US/3D/3G

 

Product characteristics

Number of inputs and outputs Number of digital outputs: 2
Factory setting oils; oil-based media; powder
Process connection threaded connection G 1/2 sealing cone
 

Application

Special feature Gold-plated contacts
Media Liquids; viscous media; powder
Cannot be used for See the operating instructions, chapter "Function and features".
Medium temperature [°C] -20...85
Probe length [mm] 153
Tank pressure [bar] -1...40
 

Electrical data

Operating voltage [V] 18...30 DC
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Measuring principle capacitive
 

Inputs / outputs

Number of inputs and outputs Number of digital outputs: 2
 

Outputs

Total number of outputs 2
Output signal switching signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
 

Measuring/setting range

Factory setting oils; oil-based media; powder
 

Response times

Response time [s] < 0.5
 

Interfaces

Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
Default 642
 

Operating conditions

Ambient temperature [°C] -20...60
Storage temperature [°C] -40...85
Protection IP 67; (when used outside the hazardous area: IP 68 / IP 69)
 

Tests / approvals

ATEX marking II 3D Ex tc IIIC T90°C Dc X
   II 3G Ex nA IIC T4 Gc X
EMC
DIN EN 61000-6-2  
DIN EN 61000-6-4 closed tanks
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 8 g (10...2000 Hz)
MTTF [years] 222
 

Mechanical data

Weight [g] 329
Materials stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts) stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; surface characteristics: Ra < 0,8 / Rz 4; FKM
Process connection threaded connection G 1/2 sealing cone
 

Displays / operating elements

Display
switching status LED, yellow
operating status LED, green
 

Remarks

Pack quantity 1 pcs.
 

Electrical connection

Connection Connector: 1 x M12; coding: A; Contacts: gold-plated


- Tài liệu kỹ thuật IFM LMT03A | LMDCE-A12E-QSKG-1/US/3D/3G ở đây.


Tham khảo thêm các model khác cùng loại:

LMT01A

Probe length L –
Level measurement –
Factory setting oils
oil-based media powder
Probe length 11 mm
Electrical design PNP/NPN

LMT03A

Probe length L –
Level measurement –
Factory setting oils
oil-based media powder
Probe length 153 mm
Electrical design PNP/NPN

LMT04A

Probe length L –
Level measurement –
Factory setting oils
oil-based media powder
Probe length 253 mm
Electrical design PNP/NPN

LMT100

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -40...100 °C; [water]: Medium temperature -40...100 °C

LMT102

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -20...100 °C; [water]: Medium temperature -20...100 °C

LMT110

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -40...100 °C; [water]: Medium temperature -40...100 °C

LMT104

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -20...100 °C; [water]: Medium temperature -20...100 °C

LMT105

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -20...100 °C; [water]: Medium temperature -20...100 °C

LMT121

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -40...100 °C; [water]: Medium temperature -40...100 °C

LMT01A

Sensor for point level detection in hazardous areas
Electronic level sensor; PNP/NPN; switching signal; IO-Link; Medium temperature -20...85 °C; G 1/2 sealing cone; Connector

LMT03A

Sensor for point level detection in hazardous areas
Electronic level sensor; PNP/NPN; switching signal; IO-Link; Medium temperature -20...85 °C; G 1/2 sealing cone; Connector

LMT04A

Sensor for point level detection in hazardous areas
Electronic level sensor; PNP/NPN; switching signal; IO-Link; Medium temperature -20...85 °C; G 1/2 sealing cone; Connector

LMT191

Level sensor for limit detection with overspill protection (German Federal Water Act)
Electronic level sensor; PNP; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -40...100; (applications subject to the German Federal Water Act 0...100 °C) °C; [water]: Medium temperature -40...85; (applications subject to the German Federal Water Act : 0...85 °C) °C

LMT192

Level sensor for limit detection with overspill protection (German Federal Water Act)
Electronic level sensor; PNP; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -25...100; (applications subject to the German Federal Water Act 0...100 °C) °C; [water]: Medium temperature -25...85; (applications subject to the German Federal Water Act : 0...85 °C) °C

LMT194

Level sensor for limit detection with overspill protection (German Federal Water Act)
Electronic level sensor; PNP; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -25...100; (applications subject to the German Federal Water Act 0...100 °C) °C; [water]: Medium temperature -25...85; (applications subject to the German Federal Water Act : 0...85 °C) °C

LMT195

Level sensor for limit detection with overspill protection (German Federal Water Act)
Electronic level sensor; PNP; switching signal; IO-Link; G 1/2 sealing cone; Connector; [oil]: Medium temperature -25...100; (applications subject to the German Federal Water Act 0...100 °C) °C; [water]: Medium temperature -25...85; (applications subject to the German Federal Water Act : 0...85 °C) °C

LMT302

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 1 external thread; Connector; [oil]: Medium temperature -20...100 °C; [water]: Medium temperature -20...100 °C

LMT202

Sensor for point level detection
Electronic level sensor; PNP/NPN; switching signal; IO-Link; G 3/4 external thread; Connector; [oil]: Medium temperature -20...100 °C; [water]: Medium temperature -20...100 °C

LMT292

Sensor for point level detection
Electronic level sensor; PNP; switching signal; IO-Link; G 3/4 external thread; Connector; [oil]: Medium temperature -25...100; (applications subject to the German Federal Water Act 0...100 °C) °C; [water]: Medium temperature -25...85; (applications subject to the German Federal Water Act : 0...85 °C) °C

LMT392

Sensor for point level detection
Electronic level sensor; PNP; switching signal; IO-Link; G 1 external thread; Connector; [oil]: Medium temperature -25...100; (applications subject to the German Federal Water Act 0...100 °C) °C; [water]: Medium temperature -25...85; (applications subject to the German Federal Water Act : 0...85 °C) °C

 

Level sensors – use in hazardous areas

Cảm biến mức của dòng LMT giám sát mức trong tàu và bể chứa ở khu vực nguy hiểm.

Với vật liệu vỏ chất lượng cao như thép không gỉ hoặc PEEK cũng như các kết nối quy trình vệ sinh, cảm biến đặc biệt phù hợp với ngành thực phẩm và đồ uống. Nhiều phê duyệt hoặc chứng nhận quốc tế như EHEDG, 3A và FDA cho phép sử dụng cảm biến trong các ứng dụng vệ sinh.

Các thiết bị này có thể được sử dụng trong hầu hết các chất lỏng, môi trường nhớt và vật liệu rời. Họ thậm chí còn phát hiện các chất bám dính cực kỳ cao (ví dụ: sốt cà chua) hoặc môi trường không dẫn điện (ví dụ: dầu thực vật). cặn và bọt được ngăn chặn một cách đáng tin cậy. Thiết bị cung cấp hai đầu ra chuyển mạch có thể được đặt độc lập với nhau để thậm chí có thể phân biệt giữa hai phương tiện.

Các cảm biến được cung cấp với độ dài đầu dò khác nhau.

Mỗi cảm biến LMT được cài đặt sẵn tại nhà máy cho một phương tiện cụ thể. Đối với các yêu cầu đặc biệt, độ nhạy và các chức năng khác có thể được điều chỉnh cho phù hợp với ứng dụng tương ứng. Ví dụ, các tia bắn, chuyển động của sóng và bọt khí có thể được bù đắp bằng cách đặt độ trễ chuyển đổi.

​Các tham số được đặt thông qua IO-Link, ví dụ: sử dụng giao diện USB. Phần mềm LINERECORDER SENSOR được sử dụng để hiển thị, truyền và lưu trữ các bộ tham số.
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại