Công tắc báo mức điểm điện dung Siemens 7ML5631-0AA00-0HB0

Công tắc báo mức điểm điện dung Siemens 7ML5631-0AA00-0HB0

834
Nhà sản xuất:

Siemens

;   

Xuất xứ: Germany

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Công tắc báo mức điểm điện dung Siemens 7ML5631-0AA00-0HB0

 
Product
Article Number (Market Facing Number) 7ML5631-0AA00-0HB0
Product Description Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (Threaded lengths include process thread) Extended cable, 3000 mm (118.11"), length can be shortened by customer Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
Product family Pointek CLS200 - Standard
Product Lifecycle (PLM) PM300:Active Product
Price data
Price Group / Headquarter Price Group 8L3
List Price Show prices
Customer Price Show prices
Metal Factor None
Delivery information
Export Control Regulations ECCN : EAR99 / AL : N
Standard lead time ex-works 10 Day/Days
Net Weight (kg) 2.000 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN Not available
UPC Not available
Commodity Code 90261029
LKZ_FDB/ CatalogID FI01-4
Product Group 4717
Group Code R3P5
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 20/07/17
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
Reach Information
Classifications
 
  Version Classification
eClass 12 27-20-05-03
eClass 6 27-20-05-03
eClass 7.1 27-20-05-03
eClass 8 27-20-05-03
eClass 9 27-20-05-03
eClass 9.1 27-20-05-03


Tham khảo thêm các model khác cùng loại:

7ML5631-.....-....

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BD00-1DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PVDF Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-0AA10-0CA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AC00-0HB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1AD00-0DA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AD00-0DA0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1DA00-0DA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1DD00-0JA0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1 1/2" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AB00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AC00-0CB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Dust Ignition Proof CE, RCM, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-6EA00-0JD0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0JD0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-0AE00-0JA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BB00-0HB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BC00-1DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PVDF Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AA00-0CB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (Threaded lengths include process thread) Extended cable, 3000 mm (118.11"), length can be shortened by customer Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AC00-0DD0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1DA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1DC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1 1/2" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AC00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3DA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AE00-0JA0-Z Y01+Y15

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 10001 to 15000 mm (393.7 to 590.5") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm Stainless steel tag (70 x 13 mm (2.75 x 5")): Measuring-point number/ identification (max. 27 characters), specify in plain text
 

7ML5631-1AC00-0CB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Dust Ignition Proof CE, RCM, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1AC00-0HD0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1BC00-0CB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Dust Ignition Proof CE, RCM, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1BD00-0DA0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1DA00-0CB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0JA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1DA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA00-0CC0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AB00-0HB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AC00-0DB0-Z C11+C12+C20+Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Certificates: Material Inspection Certificate EN 10204, 3.1 SIL/IEC61508 Declaration of Conformity ((SIL 2 (overspill)) Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3DA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0DA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0HB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AD00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-0BB01-1KC0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0CA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AC00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1AC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1BA00-0GB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BB00-0JA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA10-0DD0-Z C11+Y15

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (Threaded lengths include process thread) Extended cable, 3000 mm (118.11"), length can be shortened by customer Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag (70 x 13 mm (2.75 x 5")): Measuring-point number/ identification (max. 27 characters), specify in plain text
 

7ML5631-3BD00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 1" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3BF00-0JD0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 1" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 15001 to 20000 mm (590.6 to 787.4") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
Sản phẩm cùng loại
Gọi điện thoại