Công tắc báo mức điểm điện dung Siemens 7ML5631-0AA00-0HB0

Công tắc báo mức điểm điện dung Siemens 7ML5631-0AA00-0HB0

483
Nhà sản xuất: Siemens;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Công tắc báo mức điểm điện dung Siemens 7ML5631-0AA00-0HB0

 
Product
Article Number (Market Facing Number) 7ML5631-0AA00-0HB0
Product Description Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (Threaded lengths include process thread) Extended cable, 3000 mm (118.11"), length can be shortened by customer Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 .
Product family Pointek CLS200 - Standard
Product Lifecycle (PLM) PM300:Active Product
Price data
Price Group / Headquarter Price Group 8L3
List Price Show prices
Customer Price Show prices
Metal Factor None
Delivery information
Export Control Regulations ECCN : EAR99 / AL : N
Standard lead time ex-works 10 Day/Days
Net Weight (kg) 2.000 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN Not available
UPC Not available
Commodity Code 90261029
LKZ_FDB/ CatalogID FI01-4
Product Group 4717
Group Code R3P5
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 20/07/17
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
Reach Information
Classifications
 
  Version Classification
eClass 12 27-20-05-03
eClass 6 27-20-05-03
eClass 7.1 27-20-05-03
eClass 8 27-20-05-03
eClass 9 27-20-05-03
eClass 9.1 27-20-05-03


Tham khảo thêm các model khác cùng loại:

7ML5631-.....-....

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BD00-1DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PVDF Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-0AA10-0CA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AC00-0HB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1AD00-0DA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AD00-0DA0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1DA00-0DA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1DD00-0JA0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1 1/2" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AB00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AC00-0CB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Dust Ignition Proof CE, RCM, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-6EA00-0JD0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0JD0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-0AE00-0JA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BB00-0HB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BC00-1DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PVDF Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AA00-0CB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (Threaded lengths include process thread) Extended cable, 3000 mm (118.11"), length can be shortened by customer Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AC00-0DD0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1DA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1DC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1 1/2" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3AC00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3DA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AE00-0JA0-Z Y01+Y15

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 10001 to 15000 mm (393.7 to 590.5") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm Stainless steel tag (70 x 13 mm (2.75 x 5")): Measuring-point number/ identification (max. 27 characters), specify in plain text
 

7ML5631-1AC00-0CB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Dust Ignition Proof CE, RCM, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1AC00-0HD0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CSA, FM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1BC00-0CB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Dust Ignition Proof CE, RCM, ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1BD00-0DA0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x 1/2" NPT via adapter - cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1DA00-0CB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0JA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1DA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA00-0CC0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AB00-0HB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AC00-0DB0-Z C11+C12+C20+Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Certificates: Material Inspection Certificate EN 10204, 3.1 SIL/IEC61508 Declaration of Conformity ((SIL 2 (overspill)) Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3DA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0DA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AA00-0HB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0AD00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection: Threaded, 316L (1.4404) stainless steel: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-0BB01-1KC0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-0CA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AA00-0DB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1AC00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1AC00-0JB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: R 3/4" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Probe length: (length from flange face) (threaded lengths include process thread) Add order code Y01 and plain text: "Insertion length .... mm": Extended cable, 500 to 5000 mm (19.69 to 196.81") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-1BA00-0GB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BA00-0JB0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-1BB00-0JA0

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe.
 

7ML5631-3AA10-0DD0-Z C11+Y15

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 3/4" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (Threaded lengths include process thread) Extended cable, 3000 mm (118.11"), length can be shortened by customer Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000 Stainless steel tag (70 x 13 mm (2.75 x 5")): Measuring-point number/ identification (max. 27 characters), specify in plain text
 

7ML5631-3BD00-0DB0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 1" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 5001 to 10000 mm (196.85 to 393.66") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: Flameproof Enclosure With IS Probe CE, RCM, ATEX II 1/2 G EEx d(ia) IIC T6...T4 ATEX II 1/2 D T100 C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
 

7ML5631-3BF00-0JD0-Z Y01

Pointek CLS200 RF Capacitance point level switch, cable design. Detects level and interface in liquids, solids, slurries, and foam. Cable extension options to 30 m (98.43 ft), adaptable sensitivity, with the ability to tune out build-up on probe. Process Connection Threaded, 316L (1.4404) stainless steel: G 1" ((BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202) Probe length: (length from flange face) (threaded lengths include process threads) Add order code Y01 and plain text: "Insertion length ... mm" Extended cable, 15001 to 20000 mm (590.6 to 787.4") Thermal Isolator: Without thermal isolator Wetted Seals: FKM and PTFE Probe Material: FEP Jacketed cable with PPS Probe Body Approvals: General Purpose (CE, RCM) Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . Total insertion length: Enter the total insertion length in plain text description. Total insertion length xxxx mm
Sản phẩm cùng loại
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại