Công tắc đo mức điểm điện dung Siemens 7ML5642-8CA10-0DD0
Product |
Article Number (Market Facing Number) |
7ML5642-8CA10-0DD0 |
Product Description |
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications. Process Connection: Sanitary 316L (1.4404) stainless steel: 2" sanitary fitting clamp Probe length: (length from flange face) Compact, 98 mm (3.86") Thermal Isolator: With thermal isolator (for process connection temperatures over +85 C (+185 F)) Wetted Seals: FKM Probe Material: 316L Stainless Steel with PPS probe body Approvals: Intrinsically Safe CE, RCM, ATEX II 1 G EEx ia IIC T6...T4, ATEX II 1/2 D IP6X T100C Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP68 . |
Product family |
Pointek CLS200 - Digital |
Product Lifecycle (PLM) |
PM300:Active Product |
Price data |
Price Group / Headquarter Price Group |
8L3 |
List Price |
Show prices |
Customer Price |
Show prices |
Metal Factor |
None |
Delivery information |
Export Control Regulations |
ECCN : EAR99 / AL : N |
Standard lead time ex-works |
17 Day/Days |
Net Weight (kg) |
2.000 Kg |
Package size unit of measure |
Not available |
Quantity Unit |
1 Piece |
Packaging Quantity |
1 |
Additional Product Information |
EAN |
Not available |
UPC |
Not available |
Commodity Code |
90261029 |
LKZ_FDB/ CatalogID |
FI01-4 |
Product Group |
4717 |
Group Code |
R3P5 |
Country of origin |
Germany |
Compliance with the substance restrictions according to RoHS directive |
Since: 20/07/17 |
Product class |
C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
WEEE (2012/19/EU) Take-Back Obligation |
Yes |
REACH Art. 33 Duty to inform according to the current list of candidates |
|
Classifications |
|
|
Version |
Classification |
eClass |
12 |
27-20-05-03 |
eClass |
6 |
27-20-05-03 |
eClass |
7.1 |
27-20-05-03 |
eClass |
8 |
27-20-05-03 |
eClass |
9 |
27-20-05-03 |
eClass |
9.1 |
27-20-05-03 |
|
Tham khảo thêm các model khác cùng loại:
7ML5642-.....-....
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications.
7ML5642-8AN00-0LB0-ZY01
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications.
7ML5642-8BN00-1LD0-ZY01
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications.
7ML5642-8CA10-0DD0
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications.
7ML5642-8AB00-0DB0
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications.
7ML5642-8BM00-0BB0-ZY01
Pointek CLS200 RF Capacitance point level switch, digital, sanitary rod design. Detects level and interface in liquids, solids, slurries, and foam. Adjustable, 5.5 m (18.04 ft), insertion, adaptable sensitivity, with the ability to tune out build-up on probe. With display and digital communications.
Siemens 7ML5642-8AA00-0CB0
Siemens 7ML5642-8AA00-0LA0
Siemens 7ML5642-8AD00-0KD0
Siemens 7ML5642-8DA00-0EB0
Siemens 7ML5642-8DA10-0CB0
Siemens 7ML5642-8EA00-0EB0
Siemens 7ML5642-8AA00-0BA0
Siemens 7ML5642-8AA00-0BB0
Siemens 7ML5642-8AA00-0CA0
Siemens 7ML5642-8AA10-0KB0
Siemens 7ML5642-8AB00-0DB0
Siemens 7ML5642-8CA00-0BB0
Siemens 7ML5642-8AN00-0LB0-ZY01
Siemens 7ML5642-8BM00-0BB0-ZY01
Siemens 7ML5642-8BM20-0KA0-ZY01
Siemens 7ML5642-8BN00-1LD0-ZY01
Siemens 7ML5642-8CA00-0BB0-ZC12
Siemens 7ML5642-8DM10-0CB0-ZY01
Siemens 7ML5642-8DN00-0EB0-ZY01
Siemens 7ML5642-8EM00-0EB0-ZY01
Siemens 7ML5642-8AA00-0LA0
Siemens 7ML5642-8AD00-0KD0
Siemens 7ML5642-8DA00-0EB0
Siemens 7ML5642-8DA10-0CB0
Siemens 7ML5642-8EA00-0EB0
Siemens 7ML5642-8AA00-0BA0
Siemens 7ML5642-8AA00-0BB0
Siemens 7ML5642-8AA00-0CA0
Siemens 7ML5642-8AA10-0KB0
Siemens 7ML5642-8AB00-0DB0
Siemens 7ML5642-8CA00-0BB0
Siemens 7ML5642-8AN00-0LB0-ZY01
Siemens 7ML5642-8BM00-0BB0-ZY01
Siemens 7ML5642-8BM20-0KA0-ZY01
Siemens 7ML5642-8BN00-1LD0-ZY01
Siemens 7ML5642-8CA00-0BB0-ZC12
Siemens 7ML5642-8DM10-0CB0-ZY01
Siemens 7ML5642-8DN00-0EB0-ZY01
Siemens 7ML5642-8EM00-0EB0-ZY01
Siemens 7ML5642-8CA10-0DD0