Mô-đun dự phòng Phoenix Contact QUINT4-DIODE/12-24DC/2X20/1X40 - 2907719
(thay thế cho Model
QUINT-DIODE/12-24DC/2X20/1X40)
DIN rail diode module 12-24 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
Mô tả
A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, QUINT DIODE provides the solution: decoupling with diode.
Thông số kỹ thuật
Thông số đầu vào
DC operation |
Nominal input voltage range |
12 V DC ... 24 V DC |
Input voltage range |
10 V DC ... 30 V DC |
Voltage type of supply voltage |
DC |
Reverse polarity protection |
< yes60 V |
Nominal input current (IN) |
2x 20 A (-40 °C ... 60 °C) |
1x 40 A (-40 °C ... 60 °C) |
Maximum current Imax |
2x 30 A (-40 °C ... 40 °C) |
1x 60 A (-40 °C ... 40 °C) |
Input current IStatic |
2x 25 A (40 °C) |
Input current IDynamic |
2x 30 A (5 s) |
Input current ISFB |
2x 120 A (15 ms) |
Nominal input current (IN) |
2x 20 A (-25 °C ... 60 °C) |
1x 40 A (-25 °C ... 60 °C) |
Maximum current Imax |
2x 30 A (-25°C ... 40°C) |
1x 60 A (-25°C ... 40°C) |
Transient surge protection |
Varistor |
Voltage drop, input/output |
0.5 V |
Thông số đầu ra
Efficiency |
> 97 % |
Output voltage |
UIn - |
Output voltage range |
12 V DC ... 24 V DC |
Nominal output current (IN) |
40 A (Increasing power) |
20 A (Redundancy) |
Static Boost (IStat.Boost) |
45 A |
Dynamic Boost (IDyn.Boost) |
60 A (5 s) |
Selective Fuse Breaking (ISFB) |
120 A (15 ms) |
Derating |
60 °C ... 70 °C (2.5%/K) |
Power loss nominal load max. |
10 W (IOUT = 20 A) |
Connection in series |
No |
Thông số kết nối
Input |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.5 mm² |
Conductor cross section solid max. |
16 mm² |
Conductor cross section flexible min. |
0.5 mm² |
Conductor cross section flexible max. |
16 mm² |
Conductor cross section AWG min. |
10 |
Conductor cross section AWG max. |
6 |
Stripping length |
10 mm |
Screw thread |
M4 |
Tightening torque, min |
1.2 Nm |
Tightening torque max |
1.5 Nm |
Output |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.5 mm² |
Conductor cross section solid max. |
16 mm² |
Conductor cross section flexible min. |
0.5 mm² |
Conductor cross section flexible max. |
16 mm² |
Conductor cross section AWG min. |
10 |
Conductor cross section AWG max. |
6 |
Stripping length |
10 mm |
Screw thread |
M4 |
Tightening torque, min |
1.2 Nm |
Tightening torque max |
1.5 Nm |
Thông số điện
Insulation voltage input, output / housing |
1000 V |
Đặc tính
Product type |
Redundancy module |
Product family |
QUINT DIODE |
MTBF (IEC 61709, SN 29500) |
40000000 h (40 °C) |
Insulation characteristics |
Protection class |
III |
Degree of pollution |
2 |
Kích thước
Dimensional drawing |
 |
Width |
50 mm |
Height |
130 mm |
Depth |
125 mm |
Installation dimensions |
Installation distance right/left |
5 mm / 5 mm |
Installation distance top/bottom |
50 mm / 50 mm |
Thông số lắp đặt
Mounting type |
DIN rail mounting |
Assembly instructions |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
Đặt tính cơ học
Flammability rating according to UL 94 (housing / terminal blocks) |
V0 |
Housing material |
Metal |
Housing material |
Aluminum / stainless steel |
Điều kiện môi trường vận hành
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Maximum altitude |
≤ 5000 m |
Climatic class |
3K22 (in accordance with EN 60721-3-3) |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g, 90 min. |
Quy-Chuẩn
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety |
EN 60950-1/VDE 0805 (SELV) |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
Standard – Safety extra-low voltage |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation |
DIN VDE 0100-410 |
Approval data
UL approvals |
UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Conformity/Approvals |
ATEX |
II 3 G Ex ec IIC T4 Gc |
DEKRA 20ATEX0041 X |
IECEx |
Ex ec IIC T4 Gc |
IECEx DEK 20.0022X |
EMC data
Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
EMC requirements for noise emission |
EN 61000-6-3 |
EN 61000-6-4 |
EMC requirements for noise immunity |
EN 61000-6-1 |
EN 61000-6-2 |
Electrostatic discharge |
Standards/regulations |
EN 61000-4-2 |
Electromagnetic HF field |
Standards/regulations |
EN 61000-4-3 |
Fast transients (burst) |
Standards/regulations |
EN 61000-4-4 |
Surge voltage load (surge) |
Standards/regulations |
EN 61000-4-5 |
Conducted interference |
Standards/regulations |
EN 61000-4-6 |
Emitted interference |
Standards/regulations |
EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Thông số thương mại
Item number |
2907719 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product Key |
CMRI43 |
Catalog Page |
Page 306 (C-4-2019) |
GTIN |
4055626231211 |
Weight per Piece (including packing) |
891.58 g |
Weight per Piece (excluding packing) |
767 g |
Customs tariff number |
85049090 |
Country of origin |
CN |
- Tài liệu kỹ thuật Phoenix Contact QUINT4-DIODE/12-24DC/2X20/1X40 - 2907719
ở đây.
Tham khảo thêm các model khác cùng loại:
Redundancy module
QUINT4-ORING/12-24DC/2X20/2X20 - 1088207
Active redundancy module QUINT ORING with decoupling MOSFET, ACB Technology, DIN rail mounting, 12 V DC ... 24 V DC, 2x 20 A, 2x 20 A
Redundancy module
QUINT4-ORING/12-24DC/2X10/2X10 - 1088206
Active redundancy module QUINT ORING with decoupling MOSFET, ACB Technology, DIN rail mounting, 12 V DC ... 24 V DC, 2x 10 A, 2x 10 A
Redundancy module, with protective coating
QUINT-ORING/24DC/2X20/1X40 - 2320186
Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 20 A, output: 24 V DC/1 x 40 A, including mounted UTA 107/30 universal DIN rail adapter
Redundancy module
QUINT4-S-ORING/12-24DC/1X40 - 2907752
Active QUINT single redundancy module for DIN rail mounting, input: 12 V DC ... 24 V DC, output: 12 V DC ... 24 V DC / 1 x 40 A, incl. mounted UTA 107/30 universal DIN rail adapter
Redundancy module
QUINT-ORING/24DC/2X40/1X80 - 2902879
Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter
Redundancy module, with protective coating
QUINT-ORING/24DC/2X10/1X20 - 2320173
Active QUINT redundancy module for DIN rail mounting with Auto Current Balancing ACB technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 10 A or 1 x 20 A, including mounted UTA 107/30 universal DIN rail adapter
Redundancy module, with protective coating
QUINT4-S-ORING/12-24DC/1X40/+ - 2907753
Active QUINT single redundancy module for DIN rail mounting, protective coating, input: 12 V DC ... 24 V DC, output: 12 V DC ... 24 V DC / 1 x 40 A, integrated surge protection <28.8 V DC, incl. mounted UTA 107/30 universal DIN rail adapter
Redundancy module, with protective coating
QUINT4-S-ORING/12-24DC/1X40/VP - 1043418
Active QUINT single redundancy module for DIN rail mounting, protective coating, input: 12 V DC ... 24 V DC, output: 12 V DC ... 24 V DC / 1 x 40 A, integrated surge protection <30 V DC, incl. mounted UTA 107/30 universal DIN rail adapter
Redundancy module
QUINT4-DIODE/12-24DC/2X20/1X40 - 2907719
DIN rail diode module 12-24 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
Redundancy module
QUINT-DIODE/12-24DC/2X20/1X40 - 2320157
DIN rail diode module 12-24 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
Redundancy module
STEP3-DIODE/5-24DC/2X5/1X10/PT - 1283937
Redundancy module STEP DIODE, DIN rail mounting, 5 V DC ... 24 V DC, 2x 5 A DC, 1x 10 A
Redundancy module
STEP-DIODE/5-24DC/2X5/1X10 - 2868606
Redundancy module, 5 ... 24 V DC, 2x 5 A, 1x 10 A
Redundancy module
TRIO2-DIODE/12-24DC/2X20/1X40 - 2907379
Redundancy module, 12 V - 24 V DC, 2 x 20 A, 1 x 40 A
Redundancy module
TRIO2-DIODE/12-24DC/2X10/1X20 - 2907380
Redundancy module, 12 V - 24 V DC, 2 x 10 A, 1 x 20 A
Redundancy module
UNO-DIODE/5-24DC/2X10/1X20 - 2905489
Redundancy module, 5 V - 24 V DC, 2 x 10 A, 1 x 20 A.
Redundancy module
TRIO-DIODE/12-24DC/2X10/1X20 - 2866514
Redundancy module with function monitoring, 12 ... 24 V DC, 2x 10 A, 1x 20 A
Redundancy module
QUINT-DIODE/48DC/2X20/1X40 - 2320160
DIN rail diode module 48 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
Redundancy module
QUINT4-DIODE/48DC/2X20/1X40 - 2907720
DIN rail diode module 48 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
Redundancy module
TRIO-DIODE/48DC/2X10/1X20 - 2866527
Redundancy module with function monitoring, 48 V DC, 2x 10 A, 1x 20 A