TYPE | PFEA111 | PFEA112 | PFEA113 | |
Power supply | ||||
IP 20 Voltage | DC 24 V (18 - 36 V) | |||
Power Requirement | 7.5 W | 7.5 W | 12 W | |
IP 65 Main voltage | DC 24 V (18 - 36 V) 100 (-15%) - 240 (+10%) V AC | |||
Frequency | 45 - 65 Hz | |||
Number of load cells | 2 | 2 | 4 | |
Load cell excitation | ||||
Current | 0.5 A rms, 330 Hz | 0.5 A rms, 330 Hz | 0.5 A rms, 330 Hz | |
Max. load | 2 load cells plus 5 Ω cable resistance | 2 load cells plus 5 Ω cable resistance | 4 load cells plus 10 Ω cable resistance | |
Inputs | ||||
Digital inputs | - | - | 1 | |
Analog inputs | - | - | 2 | |
Outputs | ||||
Analog outputs (voltage or current) | - | - | 6 | |
-5 - +11V | 1 | 1 | - | |
0 - 21 mA | 1 | 1 | - | |
Selectable filter | 15, 30, 75, 250, 750, 1500 ms | 15, 30, 75, 250, 750, 1500 ms | 5, 15, 30, 75, 250, 750, 1500 ms | |
Scaling function for analog outputs | Yes | Yes | Yes | |
Digital outputs | - | - | 4 | |
Self diagnostics, Status OK | ||||
LED (green/red) | Yes | Yes | Yes | |
Alarm on Digital output | - | - | Yes | |
Alarm via Profibus | - | Yes | Yes | |
Multi language interactive display | Yes | Yes | Yes | |
Selectable tension units on the display | N, kN, kg and lbs., N/m, kN/m, kg/m, pli | |||
Maximum load memory | Yes | Yes | Yes | |
Zero offset memory | Yes | Yes | Yes | |
Communication | ||||
Profibus DP | - | Yes | Yes | |
GSD-file | ABB_0716.GSD | ABB_0717.GSD | ||
Environmental tolerance | ||||
Electrical environment | ||||
Electrical interference environment | As per EMC Directive 2014/30/EU | |||
Electrical safety | As per Low Voltage Directive 2014/35/EU | |||
As per UL508 Industrial control equipment | ||||
Ambient temperature | +5 - +55°C | |||
Degree of protection | IEC 529 Protection class IP 20 or IP 65 |