| Height | 95.2 mm |
| Width | 106.8 mm |
| Depth | 74.5 mm |
| Horizontal pitch | 6 Div. |
| Degree of protection | IP20 (only when all terminal points are used) |
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 5g (5 - 500 Hz/2.5 h/X, Y, Z) |
| IEC test classification | I + II |
| T1 + T2 | |
| T1 | |
| I | |
| EN type | T1 + T2 |
| T1 | |
| IEC power supply system | TN-S |
| TT | |
| Mode of protection | L-N |
| L-PE | |
| N-PE | |
| Mounting type | DIN rail: 35 mm |
| Color | light grey RAL 7035 |
| traffic grey A RAL 7042 | |
| Housing material | PA 6.6-FR 20% GF |
| PBT-FR | |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | DIN rail module, two-section, divisible |
| Number of positions | 3 |
| Surge protection fault message | Optical, remote indicator contact |
| Nominal voltage UN | 240/415 V AC (TN-S) |
| 240/415 V AC (TT) | |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 350 V AC |
| Rated load current IL | 125 A (< 55 °C) |
| Residual current IPE | ≤ 0.01 mA |
| Nominal discharge current In (8/20) µs (L-N) | 25 kA |
| Nominal discharge current In (8/20) µs (L-PE) | 25 kA |
| Nominal discharge current In (8/20) µs (N-PE) | 100 kA |
| Impulse discharge current (10/350) µs (L-N), charge | 12.5 As |
| Impulse discharge current (10/350) µs (L-N), specific energy | 160 kJ/Ω |
| Impulse discharge current (10/350) µs (L-N), peak current value Iimp | 25 kA |
| Impulse discharge current (10/350) µs (L-PE), charge | 12.5 As |
| Impulse discharge current (10/350) µs (L-PE), specific energy | 160 kJ/Ω |
| Impulse discharge current (10/350) µs (L-PE), peak current value Iimp | 25 kA |
| Impulse discharge current (10/350) µs (N-PE), charge | 50 As |
| Impulse discharge current (10/350) µs (N-PE), specific energy | 2500 kJ/Ω |
| Impulse discharge current (10/350) µs (N-PE), peak current value Iimp | 100 kA |
| Follow current interrupt rating Ifi (L-N) | 25 kA (264 V AC) |
| 3 kA (350 V AC) | |
| Follow current interrupt rating Ifi (N-PE) | 100 A (350 V AC) |
| Short-circuit current rating ISCCR | 25 kA (264 V AC) |
| 3 kA (350 V AC) | |
| Voltage protection level Up (L-N) | ≤ 1.5 kV |
| Voltage protection level Up (L-PE) | ≤ 2.2 kV |
| Voltage protection level Up (N-PE) | ≤ 1.5 kV |
| Residual voltage Ures (L-N) | ≤ 1.5 kV (at In) |
| ≤ 1.2 kV (at 10 kA) | |
| ≤ 1 kV (at 5 kA) | |
| ≤ 0.9 kV (at 3 kA) | |
| Residual voltage Ures (L-PE) | ≤ 2.2 kV (at In) |
| ≤ 2 kV (at 10 kA) | |
| ≤ 1.8 kV (at 5 kA) | |
| ≤ 1.6 kV (at 3 kA) | |
| Residual voltage Ures (N-PE) | ≤ 1.5 kV (at In) |
| ≤ 1 kV (at 10 kA) | |
| ≤ 0.9 kV (at 5 kA) | |
| ≤ 0.8 kV (at 3 kA) | |
| TOV behavior at UT (L-N) | 415 V AC (5 s / withstand mode) |
| 457 V AC (120 min / safe failure mode) | |
| TOV behavior at UT (N-PE) | 1200 V AC (200 ms / withstand mode) |
| Response time tA (L-N) | ≤ 25 ns |
| Response time tA (N-PE) | ≤ 100 ns |
| Max. backup fuse with V-type through wiring | 125 A (gG) |
| Max. backup fuse with branch wiring | 315 A (gG) |
| Maximum discharge current Imax (8/20) µs (L-N) | 50 kA |
| Maximum discharge current Imax (8/20) µs (L-PE) | 50 kA |
| Maximum discharge current Imax (8/20) µs (N-PE) | 100 kA |
| Switching function | PDT contact |
| Operating voltage | 12 V AC ... 250 V AC |
| 125 V DC (200 mA DC) | |
| Operating current | 10 mA AC ... 1 A AC |
| 1 A DC (30 V DC) | |
| Connection method | Plug-in/screw connection via COMBICON |
| Screw thread | M2 |
| Tightening torque | 0.25 Nm |
| Stripping length | 7 mm |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Connection method | Screw terminal blocks |
| Screw thread | M5 |
| Tightening torque | 4.5 Nm |
| Stripping length | 18 mm |
| Conductor cross section flexible | 2.5 mm² ... 35 mm² |
| Conductor cross section solid | 2.5 mm² ... 35 mm² |
| Conductor cross section AWG | 13 ... 2 |
| Connection method | Fork-type cable lug |
| Conductor cross section flexible | 1.5 mm² ... 16 mm² |
| SPD Type | 4CA |
| Maximum continuous operating voltage MCOV (L-L) | 528 V AC |
| Maximum continuous operating voltage MCOV (L-N) | 264 V AC |
| Maximum continuous operating voltage MCOV (L-G) | 528 V AC |
| Maximum continuous operating voltage MCOV (N-G) | 264 V AC |
| Nom. voltage | 240/415 V AC |
| Mode of protection | L-L |
| L-N | |
| L-G | |
| N-G | |
| Power distribution system | 3Y |
| Nominal frequency | 50/60 Hz |
| Measured limiting voltage MLV (L-L) | 2470 V |
| Measured limiting voltage MLV (L-N) | 1340 V |
| Measured limiting voltage MLV (L-G) | 1550 V |
| Measured limiting voltage MLV (N-G) | 1080 V |
| Nominal discharge current In (L-L) | 20 kA |
| Nominal discharge current In (L-N) | 20 kA |
| Nominal discharge current In (L-G) | 20 kA |
| Nominal discharge current In (N-G) | 20 kA |
| Operating voltage | 125 V AC |
| Operating current | 1 A AC |
| Tightening torque | 4 lbf-in. |
| Conductor cross section AWG | 30 ... 14 |
| Conductor cross section AWG | 12 ... 2 |
| Tightening torque | 40 lbf-in. |
| Standards/regulations | IEC 61643-11 2011 |
| EN 61643-11 2012 |
| REACh SVHC | Lead 7439-92-1 |
| eCl@ss 5.1 | 27140200 |
| eCl@ss 6.0 | 27130800 |
| eCl@ss 7.0 | 27130808 |
| eCl@ss 8.0 | 27130808 |
| eCl@ss 9.0 | 27130808 |
| ETIM 5.0 | EC001457 |
| ETIM 6.0 | EC001457 |
| UNSPSC 13.2 | 39121620 |
-Phoenix-Contact-FLT-SEC-T1-T2-2S-350-25-FM-2905468.png)
-Phoenix-Contact-FLT-SEC-T1-T2-2S-350-25-FM-2905468.png)
Thiết bị chống sét lan truyền đường nguồn 2 pha, 4 dây (L1, L2, N, PE) Loại T2Giá tốt nhất xem...0909186879 Email
Thiết bị chống sét lan truyền đường nguồn 2 pha, 3 dây (L1, L2, PEN) Loại T2 -Giá tốt nhất xem...0909186879 Email
Thiết bị chống sét lan truyền quang điện mặt trời Solar PV T2 1000vDC 40kA -Giá tốt nhất xem...0909186879 Email
Thiết bị kết hợp cắt sét và chống sét lan truyền T1+T2 cho điện mặt trời 600vDCGiá tốt nhất xem...0909186879 Email
Chống sét Phoenix Contact VAL-MS 230/3+1 - 2838209 | T2 3P 40kA 25nsGiá tốt nhất Xem...0909186879 Email
Thiết bị chống sét lan truyền đường nguồn 3 pha, 4 dây (L1, L2, L3, PEN) Loại T1 -Phoenix Contact -FLT-SEC-P-T1-3C-350/25-FM 2905419Giá tốt nhất Xem...0909186879 Email
Thiết bị chống sét lan truyền quang điện mặt trời Solar PV T2 600vDC 40kA - DEHN - DG YPV SCI 600 - Part No. 950531Giá tốt nhất Xem...0909186879 Email
Thiết bị chống sét lan truyền đường nguồn 3 pha, 5 dây (L1, L2, L3, N, PE) loại T2 - Phoenix Contact - VAL-SEC-T2-3S-350-FM 2905340Giá tốt nhất Xem...0909186879 Email
Chống sét Phoenix Contact VAL-MS 230/1+1 - 2804429 | T2 40kA 25ns 1P L1-N-PEGiá tốt nhất Xem...0909186879 Email
Thiết bị chống sét lan truyền quang điện mặt trời Solar PV T2 1000vDC 40kA - DEHN - DG YPV SCI 1000 950530Giá tốt nhất Xem...0909186879 Email