QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC ... 56 V DC are covered.
Technical Data
Input data
Nominal input voltage range |
100 V AC ... 240 V AC |
Input voltage range |
85 V AC ... 264 V AC |
90 V DC ... 350 V DC (UL 508: ≤ 250 V DC) |
Input voltage range AC |
85 V AC ... 264 V AC |
Input voltage range DC |
90 V DC ... 350 V DC (UL 508: ≤ 250 V DC) |
Electric strength, max. |
300 V AC |
Voltage type of supply voltage |
AC/DC |
Inrush current |
< 15 A (typical) |
Inrush current integral (I2t) |
< 1.5 A2s |
AC frequency range |
45 Hz ... 65 Hz |
Frequency range DC |
0 Hz |
Mains buffering time |
> 65 ms (120 V AC) |
> 65 ms (230 V AC) |
Current consumption |
1.9 A (120 V AC) |
0.9 A (230 V AC) |
1.9 A (110 V DC) |
0.9 A (220 V DC) |
Nominal power consumption |
210 VA |
Protective circuit |
Transient surge protection; Varistor |
Typical response time |
< 0.5 s |
Input fuse |
6.3 A (slow-blow, internal) |
Permissible backup fuse |
B10 B16 AC: |
Permissible DC backup fuse |
DC: Connect a suitable fuse upstream |
Recommended breaker for input protection |
10 A ... 16 A (AC: Characteristics B, C, D, K) |
Discharge current to PE |
< 3.5 mA |
Output data
Efficiency |
> 89 % (for 230 V AC and nominal values) |
Output characteristic |
U/I |
Nominal output voltage |
12 V DC ±1 % |
Setting range of the output voltage (USet) |
5 V DC ... 18 V DC (> 12 V DC, constant capacity restricted) |
Nominal output current (IN) |
15 A (-25 °C ... 60 °C) |
POWER BOOST (IBoost) |
16 A (-25 °C ... 40 °C permanent) |
Selective Fuse Breaking (ISFB) |
60 A (12 ms) |
Magnetic circuit breaker tripping |
B2 / B4 / B6 / C2 / C4 |
Derating |
60 °C ... 70 °C (2.5%/K) |
Feedback voltage resistance |
max. 25 V DC |
Protection against overvoltage at the output (OVP) |
< 25 V DC |
Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
< 2 % (change in load, dynamic 10 % ... 90 %) |
< 0.1 % (change in input voltage ±10 %) |
Residual ripple |
< 10 mVPP (with nominal values) |
Short-circuit-proof |
yes |
Output power |
180 W |
Maximum no-load power dissipation |
5 W |
Power loss nominal load max. |
21 W |
Rise time |
< 0.5 ms |
Connection in parallel |
yes, for redundancy and increased capacity |
Connection in series |
yes |
Signal: DC OK active |
Output description |
UOUT > 0.9 x UN: High signal |
Switching voltage range |
5 V DC ... 12 V DC |
Output voltage |
12 V DC |
Maximum inrush current |
≤ 20 mA (short-circuit-proof) |
Continuous load current |
≤ 20 mA |
Signal: DC OK floating |
Output description |
Relay contact, UOUT > 0.9 x UN: Contact closed |
Maximum switching voltage |
30 V AC |
24 V DC |
Maximum inrush current |
0.5 A |
1 A |
Continuous load current |
1 A |
Signal: POWER BOOST, active |
Output description |
IOUT < IN: High signal |
Switching voltage range |
5 V DC ... 12 V DC |
Output voltage |
12 V DC |
Maximum inrush current |
≤ 20 mA (short-circuit-proof) |
Continuous load current |
≤ 20 mA |
Connection data
Input |
Connection method |
Pluggable screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
16 |
Conductor cross section AWG max. |
12 |
Stripping length |
7 mm |
Screw thread |
M3 |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Output |
Connection method |
Pluggable screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
16 |
Conductor cross section AWG max. |
12 |
Stripping length |
7 mm |
Screw thread |
M3 |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Signal |
Connection method |
Pluggable screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
16 |
Conductor cross section AWG max. |
12 |
Screw thread |
M3 |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Signaling
Types of signaling |
LED |
Active switching output |
Relay contact |
Signal output: DC OK active |
Status display |
UOUT > 0.9 x UN: "DC OK" LED green |
Note on status display |
UOUT < 0.9 x UN: Flashing "DC OK" LED |
IOUT < IN: LED ON |
Signal output: DC OK floating |
Status display |
UOUT > 0.9 x UN: "DC OK" LED green |
Note on status display |
UOUT < 0.9 x UN: Flashing "DC OK" LED |
Signal output: POWER BOOST, active |
Status display |
IOUT > IN: LED "BOOST" yellow |
Electrical properties
Number of phases |
1.00 |
Insulation voltage input/output |
4 kV AC (type test) |
2 kV AC (routine test) |
Insulation voltage output / PE |
500 V DC (routine test) |
Insulation voltage input / PE |
3.5 kV AC (type test) |
2 kV AC (routine test) |
Product properties
Product type |
Power supply |
Product family |
QUINT POWER |
MTBF (IEC 61709, SN 29500) |
> 1000000 h (25 °C) |
> 570000 h (40 °C) |
> 250000 h (60 °C) |
Insulation characteristics |
Protection class |
I |
Degree of pollution |
2 |
Dimensions
Width |
60 mm |
Height |
130 mm |
Depth |
125 mm |
Installation dimensions |
Installation distance right/left |
5 mm / 5 mm |
Installation distance top/bottom |
50 mm / 50 mm |
Alternative assembly |
Width |
122 mm |
Height |
130 mm |
Depth |
63 mm |
Mounting
Mounting type |
DIN rail mounting |
Assembly instructions |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
With protective coating |
No |
Material specifications
Housing material |
Metal |
Type of housing |
Steel sheet, zinc-plated |
Environmental and real-life conditions
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Ambient temperature (start-up type tested) |
-40 °C |
Maximum altitude |
5000 m |
Climatic class |
3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and regulations
Rail applications |
EN 50121-4 |
EN 50121-3-2 |
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
Standard - Electrical safety |
IEC 61010-2-201 (SELV) |
Standard - Equipment safety |
GS (tested safety) |
Standard - Approval for medical use |
IEC 60601-1, 2 x MOOP |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
Standard – Safety extra-low voltage |
IEC 61010-1 (SELV) |
IEC 61010-2-201 (PELV) |
Standard - Safe isolation |
IEC 61010-2-201 |
Standard - safety for equipment for measurement, control, and laboratory use |
IEC 61010-1 |
Overvoltage category |
EN 62477-1 |
III |
Approvals
CSA |
CAN/CSA-C22.2 No. 60950-1-07 |
CSA-C22.2 No. 107.1-01 |
UL approvals |
UL Listed UL 508 |
UL/C-UL Recognized UL 60950-1 |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
EMC data
Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission |
EN 61000-6-3 |
EN 61000-6-4 |
EMC requirements for noise immunity |
EN 61000-6-1 |
EN 61000-6-2 |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Noise emission |
EN 55011 (EN 55022) |
Electrostatic discharge |
Standards/regulations |
EN 61000-4-2 |
Electrostatic discharge |
Contact discharge |
8 kV (Test Level 4) |
Discharge in air |
15 kV (Test Level 4) |
Comments |
Criterion A |
Electromagnetic HF field |
Standards/regulations |
EN 61000-4-3 |
Electromagnetic HF field |
Frequency range |
80 MHz ... 1 GHz |
Test field strength |
20 V/m (Test Level 3) |
Frequency range |
1 GHz ... 2 GHz |
Test field strength |
10 V/m (Test Level 3) |
Frequency range |
2 GHz ... 3 GHz |
Test field strength |
10 V/m (Test Level 3) |
Comments |
Criterion A |
Fast transients (burst) |
Standards/regulations |
EN 61000-4-4 |
Fast transients (burst) |
Input |
4 kV (Test Level 4 - asymmetrical) |
Output |
2 kV (Test Level 3 - asymmetrical) |
Signal |
2 kV (Test Level 4 - asymmetrical) |
Comments |
Criterion A |
Surge voltage load (surge) |
Standards/regulations |
EN 61000-4-5 |
Input |
2 kV (Test Level 3 - symmetrical) |
4 kV (Test Level 4 - asymmetrical) |
Output |
1 kV (Test Level 2 - symmetrical) |
2 kV (Test Level 3 - asymmetrical) |
Signal |
1 kV (Test Level 2 - asymmetrical) |
Comments |
Criterion A |
Conducted interference |
Standards/regulations |
EN 61000-4-6 |
Conducted interference |
I/O/S |
asymmetrical |
Frequency range |
0.15 MHz ... 80 MHz |
Comments |
Criterion A |
Voltage |
10 V (Test Level 3) |
Emitted interference |
Standards/regulations |
EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria |
Criterion A |
Normal operating behavior within the specified limits. |
Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Commercial Data
Item number |
2866718 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product Key |
CMPQ12 |
Catalog Page |
Page 212 (C-4-2017) |
GTIN |
4046356307888 |
Weight per Piece (including packing) |
1,510 g |
Weight per Piece (excluding packing) |
1,100 g |
Customs tariff number |
85044083 |
Country of origin |
TH |
Classifications
ECLASS
ECLASS-11.0 |
27040701 |
ECLASS-12.0 |
27040701 |
ECLASS-13.0 |
27040701 |
ETIM
UNSPSC
Approvals
cUL Recognized
Approval ID: FILE E 211944
UL Recognized
Approval ID: FILE E 211944
IECEE CB Scheme
Approval ID: SI-2093 A1
EAC
Approval ID: EAC-Zulassung
EAC
Approval ID: EAC-Zulassung
UL Listed
Approval ID: FILE E 123528
cUL Listed
Approval ID: FILE E 123528
EAC
Approval ID: RU S-DE.BL08.W.00764
UL Recognized
Approval ID: FILE E 211944
IECEE CB Scheme
Approval ID: SI-2093 A1
cUL Recognized
Approval ID: FILE E 211944
cUL Listed
Approval ID: FILE E 123528
UL Listed
Approval ID: FILE E 123528
EAC
Approval ID: RU S-DE.BL08.W.00764
EAC
Approval ID: RU S-DE.BL08.W.00764
EAC
Approval ID: RU S-DE.BL08.W.00764
cCSAus
Approval ID: 2162673
cCSAus
Approval ID: 2162673
cUL Listed
Approval ID: FILE E 199827
UL Listed
Approval ID: FILE E 199827
UL Listed
Approval ID: FILE E 199827
cUL Listed
Approval ID: FILE E 199827
Environmental Product Compliance
|
REACh SVHC |
Lead 7439-92-1 |
|
China RoHS |
Environmentally Friendly Use Period = 25; |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
- Tài liệu kỹ thuật Phoenix Contact QUINT-PS/1AC/12DC/15 - 2866718
ở đây.
Compatible Products
All DIN rail adapter Mounting adapter Redundancy module Thermomagnetic device circuit breaker Type 3 surge protection device
Product type
UTA 107 - 2853983
DIN rail adapter
UWA 182/52 - 2938235
Mounting adapter
QUINT-PS-ADAPTERS7/2 - 2938206
Mounting adapter
QUINT-DIODE/12-24DC/2X20/1X40 - 2320157
Redundancy module
TRIO-DIODE/12-24DC/2X10/1X20 - 2866514
Redundancy module
CB TM1 1A SFB P - 2800836
Thermomagnetic device circuit breaker
CB TM1 2A SFB P - 2800837
Thermomagnetic device circuit breaker
CB TM1 3A SFB P - 2800838
Thermomagnetic device circuit breaker
CB TM1 4A SFB P - 2800839
Thermomagnetic device circuit breaker
CB TM1 5A SFB P - 2800840
Thermomagnetic device circuit breaker
PLT-SEC-T3-230-FM-UT - 2907919
Type 3 surge protection device
PLT-SEC-T3-24-FM-UT - 2907916
Type 3 surge protection device
Tham khảo thêm các model khác cùng loại:
QUINT-PS/1AC/12DC/20 - Power supply unit
2866721
Primary-switched power supply unit QUINT POWER, Screw connection, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 12 V DC / 20 A
QUINT4-PS/1AC/12DC/15 - Power supply unit
2904608
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (Selective Fuse Breaking) Technology, and NFC interface, input: 1-phase, output: 12 V DC / 15 A
QUINT4-PS/1AC/12DC/2.5/PT - Power supply unit
2904605
Primary-switched power supply unit QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 2.5 A
QUINT4-PS/1AC/12DC/7.5/PT - Power supply unit
2904607
Primary-switched power supply unit QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 7.5 A