QUINT POWER power supplies with maximum functionality

QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur.

Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5 V DC ... 56 V DC are covered.

 

Technical Data

Input data

Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 85 V AC ... 264 V AC
90 V DC ... 350 V DC (UL 508: ≤ 250 V DC)
Input voltage range AC 85 V AC ... 264 V AC
Input voltage range DC 90 V DC ... 350 V DC (UL 508: ≤ 250 V DC)
Electric strength, max. 300 V AC
Voltage type of supply voltage AC/DC
Inrush current < 15 A (typical)
Inrush current integral (I2t) < 1.5 A2s
AC frequency range 45 Hz ... 65 Hz
Frequency range DC 0 Hz
Mains buffering time > 65 ms (120 V AC)
> 65 ms (230 V AC)
Current consumption 1.9 A (120 V AC)
0.9 A (230 V AC)
1.9 A (110 V DC)
0.9 A (220 V DC)
Nominal power consumption 210 VA
Protective circuit Transient surge protection; Varistor
Typical response time < 0.5 s
Input fuse 6.3 A (slow-blow, internal)
Permissible backup fuse B10 B16 AC:
Permissible DC backup fuse DC: Connect a suitable fuse upstream
Recommended breaker for input protection 10 A ... 16 A (AC: Characteristics B, C, D, K)
Discharge current to PE < 3.5 mA
 

Output data

Efficiency > 89 % (for 230 V AC and nominal values)
Output characteristic U/I
Nominal output voltage 12 V DC ±1 %
Setting range of the output voltage (USet) 5 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (IN) 15 A (-25 °C ... 60 °C)
POWER BOOST (IBoost) 16 A (-25 °C ... 40 °C permanent)
Selective Fuse Breaking (ISFB) 60 A (12 ms)
Magnetic circuit breaker tripping B2 / B4 / B6 / C2 / C4
Derating 60 °C ... 70 °C (2.5%/K)
Feedback voltage resistance max. 25 V DC
Protection against overvoltage at the output (OVP) < 25 V DC
Control deviation < 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 10 mVPP (with nominal values)
Short-circuit-proof yes
Output power 180 W
Maximum no-load power dissipation 5 W
Power loss nominal load max. 21 W
Rise time < 0.5 ms
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Signal: DC OK active
Output description UOUT > 0.9 x UN: High signal
Switching voltage range 5 V DC ... 12 V DC
Output voltage 12 V DC
Maximum inrush current ≤ 20 mA (short-circuit-proof)
Continuous load current ≤ 20 mA
Signal: DC OK floating
Output description Relay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage 30 V AC
24 V DC
Maximum inrush current 0.5 A
1 A
Continuous load current 1 A
Signal: POWER BOOST, active
Output description IOUT < IN: High signal
Switching voltage range 5 V DC ... 12 V DC
Output voltage 12 V DC
Maximum inrush current ≤ 20 mA (short-circuit-proof)
Continuous load current ≤ 20 mA
 

Connection data

Input
Connection method Pluggable screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Output
Connection method Pluggable screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signal
Connection method Pluggable screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 12
Screw thread M3
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
 

Signaling

Types of signaling LED
Active switching output
Relay contact
Signal output: DC OK active
Status display UOUT > 0.9 x UN: "DC OK" LED green
Note on status display UOUT < 0.9 x UN: Flashing "DC OK" LED
IOUT < IN: LED ON
Signal output: DC OK floating
Status display UOUT > 0.9 x UN: "DC OK" LED green
Note on status display UOUT < 0.9 x UN: Flashing "DC OK" LED
Signal output: POWER BOOST, active
Status display IOUT > IN: LED "BOOST" yellow
 

Electrical properties

Number of phases 1.00
Insulation voltage input/output 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE 500 V DC (routine test)
Insulation voltage input / PE 3.5 kV AC (type test)
2 kV AC (routine test)
 

Product properties

Product type Power supply
Product family QUINT POWER
MTBF (IEC 61709, SN 29500) > 1000000 h (25 °C)
> 570000 h (40 °C)
> 250000 h (60 °C)
Insulation characteristics
Protection class I
Degree of pollution 2
 

Dimensions

Width 60 mm
Height 130 mm
Depth 125 mm
Installation dimensions
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Alternative assembly
Width 122 mm
Height 130 mm
Depth 63 mm
 

Mounting

Mounting type DIN rail mounting
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting position horizontal DIN rail NS 35, EN 60715
With protective coating No
 

Material specifications

Housing material Metal
Type of housing Steel sheet, zinc-plated
 

Environmental and real-life conditions

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Ambient temperature (start-up type tested) -40 °C
Maximum altitude 5000 m
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
 

Standards and regulations

Rail applications EN 50121-4
EN 50121-3-2
Standard – Limitation of mains harmonic currents EN 61000-3-2
Standard - Electrical safety IEC 61010-2-201 (SELV)
Standard - Equipment safety GS (tested safety)
Standard - Approval for medical use IEC 60601-1, 2 x MOOP
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Safety extra-low voltage IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
Overvoltage category
EN 62477-1 III
 

Approvals

CSA CAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01
UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
 

EMC data

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 55011 (EN 55022)
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 2 GHz ... 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 4 kV (Test Level 4 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 2 kV (Test Level 3 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Emitted interference
Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
 

Commercial Data

Item number 2866718
Packing unit 1 pc
Minimum order quantity 1 pc
Product Key CMPQ12
Catalog Page Page 212 (C-4-2017)
GTIN 4046356307888
Weight per Piece (including packing) 1,510 g
Weight per Piece (excluding packing) 1,100 g
Customs tariff number 85044083
Country of origin TH
 

Classifications

ECLASS

ECLASS-11.0 27040701
ECLASS-12.0 27040701
ECLASS-13.0 27040701
 

ETIM

ETIM 8.0 EC002540
 

UNSPSC

UNSPSC 21.0 39121000


Approvals

cUL Recognized

Approval ID: FILE E 211944
 

UL Recognized

Approval ID: FILE E 211944

IECEE CB Scheme

Approval ID: SI-2093 A1
 

EAC

Approval ID: EAC-Zulassung
 

EAC

Approval ID: EAC-Zulassung
 

UL Listed

Approval ID: FILE E 123528
 

cUL Listed

Approval ID: FILE E 123528
 

EAC

Approval ID: RU S-DE.BL08.W.00764
 

UL Recognized

Approval ID: FILE E 211944
 

IECEE CB Scheme

Approval ID: SI-2093 A1
 

cUL Recognized

Approval ID: FILE E 211944
 

cUL Listed

Approval ID: FILE E 123528
 

UL Listed

Approval ID: FILE E 123528
 

EAC

Approval ID: RU S-DE.BL08.W.00764
 

EAC

Approval ID: RU S-DE.BL08.W.00764
 

EAC

Approval ID: RU S-DE.BL08.W.00764
 

cCSAus

Approval ID: 2162673
 

cCSAus

Approval ID: 2162673
 

cUL Listed

Approval ID: FILE E 199827
 

UL Listed

Approval ID: FILE E 199827
 

UL Listed

Approval ID: FILE E 199827
 

cUL Listed

Approval ID: FILE E 199827
 

Environmental Product Compliance

 
REACh SVHC Lead 7439-92-1
 
China RoHS Environmentally Friendly Use Period = 25;
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”


- Tài liệu kỹ thuật Phoenix Contact QUINT-PS/1AC/12DC/15 - 2866718 ở đây.

 

Compatible Products

All  DIN rail adapter  Mounting adapter  Redundancy module  Thermomagnetic device circuit breaker  Type 3 surge protection device 
Product type
UTA 107 - 2853983
DIN rail adapter

UWA 182/52 - 2938235
Mounting adapter

QUINT-PS-ADAPTERS7/2 - 2938206
Mounting adapter

QUINT-DIODE/12-24DC/2X20/1X40 - 2320157
Redundancy module

TRIO-DIODE/12-24DC/2X10/1X20 - 2866514
Redundancy module

CB TM1 1A SFB P - 2800836
Thermomagnetic device circuit breaker

CB TM1 2A SFB P - 2800837
Thermomagnetic device circuit breaker

CB TM1 3A SFB P - 2800838
Thermomagnetic device circuit breaker

CB TM1 4A SFB P - 2800839
Thermomagnetic device circuit breaker

CB TM1 5A SFB P - 2800840
Thermomagnetic device circuit breaker

PLT-SEC-T3-230-FM-UT - 2907919
Type 3 surge protection device

PLT-SEC-T3-24-FM-UT - 2907916
Type 3 surge protection device


Tham khảo thêm các model khác cùng loại:
QUINT-PS/1AC/12DC/20 - Power supply unit
2866721

Primary-switched power supply unit QUINT POWER, Screw connection, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 12 V DC / 20 A

QUINT4-PS/1AC/12DC/15 - Power supply unit
2904608

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (Selective Fuse Breaking) Technology, and NFC interface, input: 1-phase, output: 12 V DC / 15 A

QUINT4-PS/1AC/12DC/2.5/PT - Power supply unit
2904605

Primary-switched power supply unit QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 2.5 A

QUINT4-PS/1AC/12DC/7.5/PT - Power supply unit
2904607

Primary-switched power supply unit QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 7.5 A
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại