Thông tin chi tiết của 

Bộ nguồn Phoenix Contact 24V DC - 150W Power supply unit - UNO-PS/1AC/24DC/150W - 2904376

Output: 24VDC, 6.25A

Input AC: 85VAC - 264VAC

Vỏ nhựa, gắn trực tiếp trên Din Rail

* Sản xuất tại Đức



 

Your advantages


- Flexible mounting by simply snapping onto the DIN rail

- More space in the control cabinet with up to 20 % higher power density

- Maximum energy efficiency, thanks to over 90 % efficiency and extremely low idling losses under 0.3 W

- Outdoor installation, thanks to the wide temperature range from -25°C to +70°C


             


 

Bản vẽ thiết kế mạch của Bộ nguồn Phoenix Contact 24V DC - 150W Power supply unit - UNO-PS/1AC/24DC/150W - 2904376



 

Dimensions

Width 37 mm
Height 130 mm
Depth 125 mm



 

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2



 

Input data

Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 85 V AC ... 264 V AC
AC frequency range 45 Hz ... 65 Hz
Current consumption 1.4 A (120 V AC)
  0.8 A (230 V AC)
Nominal power consumption 159.8 W
Inrush surge current < 50 A (typical)
Power failure bypass > 20 ms (120 V AC)
  > 20 ms (230 V AC)
Input fuse 2.5 A (slow-blow, internal)
Choice of suitable circuit breakers 6 A ... 16 A (Characteristics B, C, D, K)
Type of protection Transient surge protection
Protective circuit/component Varistor



 

Output data

Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 24 V DC ... 28 V DC ±1 %
Nominal output current (IN) 6.25 A (-25 °C ... 55 °C)
Derating 55 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series No
Feedback resistance < 35 V DC
Circuit breaker against surge voltage at output by invasive foreign matter ≤ 35 V DC
Control deviation < 1 % (change in load, static 10 % ... 90 %)
  < 2 % (change in load, dynamic 10 % ... 90 %)
  < 0.1 % (change in input voltage ±10 %)
Residual ripple < 40 mVPP (with nominal values)
Output power 150 W
Typical response time < 1 s
Maximum power dissipation in no-load condition < 1.2 W
Power loss nominal load max. < 9.7 W



 

General

Net weight 0.5 kg
Efficiency > 94 % (for 230 V AC and nominal values)
Insulation voltage input/output 4 kV AC (type test)
  3 kV AC (routine test)
Protection class II (in closed control cabinet)
Degree of protection IP20
MTBF (IEC 61709, SN 29500) > 868000 h (40 °C)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions Alignable: 0 mm horizontally, 30 mm vertically



 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 8 mm
Screw thread M3



 

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 8 mm
Screw thread M3



 

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise immunity EN 61000-6-2:2005
Standards/regulations EN 61000-4-2
Contact discharge 4 kV (Test Level 2)
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1.4 GHz ... 2 GHz
Test field strength 3 V/m (Test Level 2)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
  EN 61000-6-3
  EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Standards/regulations EN 61000-4-11
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard - Safety of transformers EN 61558-2-16
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage EN 60950-1 (SELV) and EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
UL approvals UL Listed UL 508
  UL/C-UL Recognized UL 60950-1
  UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
  15 Hz ... 150 Hz, 2.3g, 90 min.
Approval - requirement of the semiconductor industry with regard to mains voltage dips EN 61000-4-11
Information technology equipment - safety (CB scheme) CB Scheme



 

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 25;
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


 

Classifications

 

eCl@ss

eCl@ss 4.0 27040702
eCl@ss 4.1 27040702
eCl@ss 5.0 27049002
eCl@ss 5.1 27049002
eCl@ss 6.0 27049002
eCl@ss 7.0 27049002
eCl@ss 8.0 27049002
eCl@ss 9.0 27040701



 

ETIM

ETIM 4.0 EC000599
ETIM 5.0 EC002540
ETIM 6.0 EC002540



 

UNSPSC

UNSPSC 13.2 39121004



 

Approvals




















 
Sản phẩm cùng loại
Gọi điện thoại