- Công nghệ kết nối bảo trì dễ dàng nhờ các đầu nối COMBICON có chìa khóa
- Giám sát từ xa điện áp đầu ra thông qua chuyển đổi đầu raWidth | 67.5 mm |
Height | 99 mm |
Depth | 107 mm |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Nominal input voltage range | 100 V AC ... 240 V AC |
Input voltage range | 85 V AC ... 264 V AC |
90 V DC ... 350 V DC | |
AC frequency range | 45 Hz ... 65 Hz |
Current consumption | 1.3 A (120 V AC) |
0.8 A (230 V AC) | |
1.3 A (90 V DC) | |
0.4 A (350 V DC) | |
Nominal power consumption | 108.3 W |
Inrush surge current | < 15 A (typical) |
Mains buffering | > 20 ms (120 V AC) |
> 100 ms (230 V AC) | |
Input fuse | 3.15 A (slow-blow, internal) |
Choice of suitable circuit breakers | 6 A ... 16 A (Characteristics B, C, D, K) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Nominal output voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) | 4 A (-25 °C ... 60 °C) |
POWER BOOST (IBoost) | 5 A (-25°C ... 40°C permanent ) |
Derating | 60 °C ... 70 °C (2.5%/K) |
Connection in parallel | Yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback resistance | 35 V DC |
Circuit breaker against surge voltage at output by invasive foreign matter | Yes, < 35 V DC |
Starting delay with capacitive load | Unrestricted |
Max. capacitive load | Unlimited |
Active current limitation | approx 9 A (in the event of a short-circuit) |
Control deviation | change in load, static 10 % ... 90 % |
< 3 % (change in load, dynamic 10 % ... 90 %) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 20 mVPP (20 MHz) |
Output power | 96 W |
Typical response time | < 0.4 s |
Peak switching voltages nominal load | < 100 mVPP (20 MHz) |
Maximum power dissipation in no-load condition | 2.5 W |
Power loss nominal load max. | 12 W |
Net weight | 0.4 kg |
Operating voltage display | Green LED |
Efficiency | > 88 % (for 230 V AC and nominal values) |
Insulation voltage input/output | 3 kV (type test) |
3 kV (routine test) | |
Protection class | II (in closed control cabinet) |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 815000 h (40 °C) |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | Can be aligned: Horizontally 0 mm, vertically 50 mm |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Screw thread | M3 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 (EN 55022) |
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | 8 kV |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m |
Frequency range | 1 GHz ... 2 GHz |
Test field strength | 3 V/m |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | 0.5 kV (level 1 - asymmetrical: conductor to ground) |
Standards/regulations | EN 61000-6-3 |
EN 61000-4-6 | |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V |
Standards/regulations | EN 61000-4-11 |
Low Voltage Directive | Conformance with LV directive 2006/95/EC |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | EN 60950-1 (SELV) |
EN 60204 (PELV) | |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
UL approvals | UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 | |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g, 90 min. | |
Rail applications | EN 50121-4 |
eCl@ss 4.0 | 27040702 |
eCl@ss 4.1 | 27040702 |
eCl@ss 5.0 | 27049002 |
eCl@ss 5.1 | 27049002 |
eCl@ss 6.0 | 27049002 |
eCl@ss 7.0 | 27049002 |
eCl@ss 8.0 | 27049002 |
eCl@ss 9.0 | 27040701 |
ETIM 2.0 | EC001039 |
ETIM 3.0 | EC001039 |
ETIM 4.0 | EC000599 |
ETIM 5.0 | EC002540 |
ETIM 6.0 | EC002540 |
UNSPSC 6.01 | 30211502 |
UNSPSC 7.0901 | 39121004 |
UNSPSC 11 | 39121004 |
UNSPSC 12.01 | 39121004 |
UNSPSC 13.2 | 39121004 |