Cảm biến điện dung 15mm M30 L90 PNP NO/NC IO-Link M12-A IFM KI5087

Cảm biến điện dung 15mm M30 L90 PNP NO/NC IO-Link M12-A IFM KI5087

337
Nhà sản xuất: IFM;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Cảm biến tiệm cận điện dung 15mm M30 L90 PNP NO/NC IO-Link M12-A IFM KI5087 | KIA3150NFPKG/2T/US

 

(IFM KI5087 xài Cáp kết nối IFM EVC004)


- Easy adjustment to the empty and full state via pushbutton or IO-Link
- Output function normally open / normally closed programmable
- Clearly visible indication of the switching status
- Robust stainless steel housing for use in harsh industrial environments
- Reliable level detection through non-metallic vessel walls

 

Thông số kỹ thuật

Product characteristics

Electrical design PNP
Output function normally open / normally closed; (selectable)
Sensing range [mm] 15
Communication interface IO-Link
Housing threaded type
Dimensions [mm] M30 x 1.5 / L = 90
 

Electrical data

Operating voltage [V] 10...30 DC; (10...36 DC (60 °C))
Current consumption [mA] < 18
Protection class III
Reverse polarity protection yes
Measuring principle capacitive
 

Outputs

Electrical design PNP
Output function normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 10
Short-circuit proof yes
Overload protection yes
 

Detection zone

Sensing range [mm] 15
 

Accuracy / deviations

Hysteresis [% of Sr] 1...15
Switch point drift [% of Sr] -20...20
 

Interfaces

Communication interface IO-Link
Transmission type COM1 (4,8 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor
SIO mode yes
Min. process cycle time [ms] 101
Supported DeviceIDs
Type of operation DeviceID
Default 388
 

Operating conditions

Ambient temperature [°C] -25...80
Protection IP 65; IP 67
 

Tests / approvals

EMC
EN 61000-4-2 ESD 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 3 V
EN 55011 class B
Vibration resistance
EN 60068-2-6 Fc (10...55 Hz) / 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea 30 g 6 shocks / 11 ms half-sine (x, y, z)
MTTF [years] 719
 

Mechanical data

Weight [g] 119.2
Housing threaded type
Mounting non-flush mountable
Dimensions [mm] M30 x 1.5 / L = 90
Thread designation M30 x 1.5
Materials housing: stainless steel (1.4404 / 316L); pushbuttons: TPE-U; cover: PBT; LED window: PEI
 

Displays / operating elements

Display
switching status 1 x LED, yellow
Teach function yes
Electronic lock yes
 

Accessories

Items supplied
lock nuts: 2
 

Remarks

Pack quantity 1 pcs.
 

Electrical connection - plug

Connection Connector: 1 x M12; coding: A


- Tài liệu kỹ thuật IFM KI5087 ở đây.

- Hướng dẫn lắp đặt, cài đặt và vận hành IFM KI5087 ở đây.


Tham khảo thêm các model khác cùng loại:
KG6000
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI6001
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
2 m PUR-Cable
KI6000
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KT5002
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KF5001
Sensing range
1...6 mm flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 60 mm
Connection
M12 Connector
KI0024
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KT5001
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
2 m PUR-Cable
KT5006
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KI5085
Sensing range
8 mm flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KG5309
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI505A
Sensing range
15 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KT5110
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
2 m PUR-Cable
KI5083
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KT5005
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
2 m PUR-Cable
KT5111
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
2 m PUR-Cable
KI5309
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KT5014
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KT5009
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
2 m PUR-Cable
KT5106
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KG5311
Sensing range
0.5...9 mm quasi flush
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI503A
Sensing range
15 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI530A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI531A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI532A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
M12 Connector
KI533A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
M12 Connector
KT5310
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KI5311
Sensing range
0.5...24 mm quasi flush
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KT5112
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KQ6001
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable
KI0203
Sensing range
3...15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI8512
Sensing range
3...15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5307
Sensing range
0.5...40 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KG5306
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KG5307
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KG6001
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG6006
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG6007
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
5 m PUR-Cable
KG5300
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG5303
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KI5306
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KQ5100
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
2 m PUR-Cable
KG5308
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KG5310
Sensing range
0.5...9 mm quasi flush
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI5308
Sensing range
0.5...40 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KI5310
Sensing range
0.5...24 mm quasi flush
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KQ6005
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
0.1 m PVC-Cable; M12 Connector
KI0209
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KT5007
Sensing range

Output function
normally open
Output
DC NPN
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KG5301
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG5304
Sensing range
0.5...9 mm quasi flush
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG5305
Sensing range
0.5...9 mm quasi flush
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KT5309
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KF5002
Sensing range
3...12 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 61 mm
Connection
M12 Connector
KG5302
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KT5010
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
2 m PUR-Cable
KQ6004
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
0.04 m PVC-Cable; M8 Connector
KT5102
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KI5002
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5087
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KQ5101
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.1 m PUR-Cable; M12 Connector
KI0202
Sensing range
3...15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KQ5102
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.04 m PUR-Cable; M8 Connector
KQ5108
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.5 m PUR-Cable; M8 Connector
KQ6002
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable
KI5023
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KI5082
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KT5013
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KT5011
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KG5065
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 87 mm
Connection
M12 Connector
KI0016
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI0065
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KI0054
Sensing range
5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 90 mm
Connection
1/2" Connector
KT5311
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KD5018
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
105 x 80 x 40 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KI0205
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KT5150
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
2 m PUR-Cable
KT5312
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KB5004
Sensing range
3...20 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KI6003
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
10 m PUR-Cable
KI6004
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
5 m PUR-Cable
KT5151
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KB0025
Sensing range
3...20 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KG5066
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 87 mm
Connection
M12 Connector
KT5012
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
2 m PUR-Cable
KG5071
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 87 mm
Connection
M12 Connector
KT5350
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KT5320
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KT5050
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
2 m PUR-Cable
KI000A
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KG5045
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI5031
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KQ5006
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.045 m PUR-Cable; M8 Connector
KI0020
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI6002
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
10 m PUR-Cable
KI5052
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 143 mm
Connection
M12 Connector
KI5030
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5038
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
valve plug type A DIN Connector
KG5043
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI5084
Sensing range
8 mm flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KI001A
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KG5047
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PUR / PVC-Cable
KG5057
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 93.8 mm
Connection
M12 Connector
KQ6003
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
20 x 14 x 48 mm
Connection
0.04 m PVC-Cable; M8 Connector
KF5013
Sensing range
1...6 mm flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M12 x 1 / L = 60 mm
Connection
M12 Connector
KB5062
Sensing range
20 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
Ø 34 / L = 93 mm
Connection
M12 Connector
KI5207
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KD501A
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
105 x 80 x 42 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KI5015
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KG0010
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KB0029
Sensing range
3...20 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KD0009
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
105 x 80 x 40 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KG0009
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI0207
Sensing range
3...15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 mm
Connection
0.1 m PVC-Cable; 1/2" Connector
KG0008
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M18 x 1 / L = 110 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm
KI0206
Sensing range
3...15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 mm
Connection
0.1 m PVC-Cable; 1/2" Connector
KQ5011
Sensing range
4 mm
Output function
normally open
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.76 m PUR-Cable; MOLEX Connector
KG5067
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 77 mm
Connection
2 m PVC-Cable
KG5069
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 77 mm
Connection
2 m PVC-Cable
KI0061
Sensing range
20 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI0040
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 92 mm
Connection
valve plug type A DIN Connector
KI0064
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 90 mm
Connection
1/2" Connector
KQ6006
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable
KG0016
Sensing range
4...24 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M18 x 1 / L = 87 mm
Connection
1/2" Connector
KI5086
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KG5070
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 77 mm
Connection
10 m PVC-Cable
KI5019
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KD001A
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
105 x 80 x 42 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KI0058
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 90 mm
Connection
1/2" Connector
KI5001
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5209
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
0.1 m PUR-Cable; M12 Connector
KG5040
Sensing range
2.5...8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 110 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm
KI5208
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KG5044
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KD5044
Sensing range
60 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
105 x 80 x 40 mm
Connection
M12 Connector
KD5039
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
105 x 80 x 40 mm
Connection
M12 Connector
KG5041
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 110 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm
KN5121
Sensing range

Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 116 mm
Connection
2 m; M12 Connector
KI5081
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KD5022
Sensing range
60 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
120 x 80 x 30 mm
Connection
2 m PVC-Cable
KD0012
Sensing range
60 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
120 x 80 x 30 mm
Connection
2 m PVC-Cable
KG5046
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI0021
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KX5001
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M34 x 1.5 / L = 92 mm
Connection
2 m PVC-Cable
KQ6016
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable; M12 Connector
KI5006
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KX5002
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M34 x 1.5 / L = 92 mm
Connection
6 m PVC-Cable
KQ6008
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
0.04 m PVC-Cable; M8 Connector
KD5019
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
105 x 80 x 40 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KD0024
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions

Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KF5015
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 70 mm
Connection
2 m PUR-Cable
KI5090
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KI5003
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KB0041
Sensing range
3...20 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KF5014
Sensing range
4 mm flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 69 mm
Connection
2 m PUR-Cable
KG5079
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M18 x 1 / L = 84 mm
Connection
6 m PVC-Cable
KX5004
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M34 x 1.5 / L = 92 mm
Connection
20 m PVC-Cable
KT5020
Sensing range

Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M12 Connector
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại