Cảm biến tiệm cận điện dung 15mm M30 L90 PNP NO/NC IO-Link M12-A IFM KI5087 | KIA3150NFPKG/2T/US
(IFM KI5087 xài Cáp kết nối IFM EVC004)
- Easy adjustment to the empty and full state via pushbutton or IO-Link
- Output function normally open / normally closed programmable
- Clearly visible indication of the switching status
- Robust stainless steel housing for use in harsh industrial environments
- Reliable level detection through non-metallic vessel walls
Thông số kỹ thuật
Product characteristics
Electrical design |
PNP |
Output function |
normally open / normally closed; (selectable) |
Sensing range [mm] |
15 |
Communication interface |
IO-Link |
Housing |
threaded type |
Dimensions [mm] |
M30 x 1.5 / L = 90 |
Electrical data
Operating voltage [V] |
10...30 DC; (10...36 DC (60 °C)) |
Current consumption [mA] |
< 18 |
Protection class |
III |
Reverse polarity protection |
yes |
Measuring principle |
capacitive |
Outputs
Electrical design |
PNP |
Output function |
normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
100 |
Switching frequency DC [Hz] |
10 |
Short-circuit proof |
yes |
Overload protection |
yes |
Detection zone
Accuracy / deviations
Hysteresis [% of Sr] |
1...15 |
Switch point drift [% of Sr] |
-20...20 |
Interfaces
Communication interface |
IO-Link |
Transmission type |
COM1 (4,8 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
Smart Sensor |
SIO mode |
yes |
Min. process cycle time [ms] |
101 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
388 |
|
Operating conditions
Ambient temperature [°C] |
-25...80 |
Protection |
IP 65; IP 67 |
Tests / approvals
EMC |
EN 61000-4-2 ESD |
8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-6 HF conducted |
3 V |
EN 55011 |
class B |
|
Vibration resistance |
EN 60068-2-6 Fc |
(10...55 Hz) / 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
|
Shock resistance |
EN 60068-2-27 Ea |
30 g 6 shocks / 11 ms half-sine (x, y, z) |
|
MTTF [years] |
719 |
Mechanical data
Weight [g] |
119.2 |
Housing |
threaded type |
Mounting |
non-flush mountable |
Dimensions [mm] |
M30 x 1.5 / L = 90 |
Thread designation |
M30 x 1.5 |
Materials |
housing: stainless steel (1.4404 / 316L); pushbuttons: TPE-U; cover: PBT; LED window: PEI |
Displays / operating elements
Display |
switching status |
1 x LED, yellow |
|
Teach function |
yes |
Electronic lock |
yes |
Accessories
Remarks
Electrical connection - plug
Connection |
Connector: 1 x M12; coding: A |
- Tài liệu kỹ thuật IFM KI5087
ở đây.
- Hướng dẫn lắp đặt, cài đặt và vận hành IFM KI5087
ở đây.
Tham khảo thêm các model khác cùng loại:
KG6000
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI6001
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
2 m PUR-Cable
KI6000
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KT5002
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KF5001
Sensing range
1...6 mm flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 60 mm
Connection
M12 Connector
KI0024
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KT5001
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
2 m PUR-Cable
KT5006
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KI5085
Sensing range
8 mm flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KG5309
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI505A
Sensing range
15 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KT5110
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
2 m PUR-Cable
KI5083
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KT5005
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
2 m PUR-Cable
KT5111
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
2 m PUR-Cable
KI5309
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KT5014
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KT5009
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 100 / L = 11 mm
Connection
2 m PUR-Cable
KT5106
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KG5311
Sensing range
0.5...9 mm quasi flush
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI503A
Sensing range
15 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI530A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI531A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm
KI532A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
M12 Connector
KI533A
Sensing range
3...26 mm non-flush mountable
Output function
complementary
Output
DC PNP
Dimensions
M30 x 1.5 / L = 150 mm
Connection
M12 Connector
KT5310
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KI5311
Sensing range
0.5...24 mm quasi flush
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KT5112
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KQ6001
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable
KI0203
Sensing range
3...15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI8512
Sensing range
3...15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5307
Sensing range
0.5...40 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KG5306
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KG5307
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KG6001
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG6006
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG6007
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
5 m PUR-Cable
KG5300
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG5303
Sensing range
0.5...30 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KI5306
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KQ5100
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
2 m PUR-Cable
KG5308
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KG5310
Sensing range
0.5...9 mm quasi flush
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
M12 Connector
KI5308
Sensing range
0.5...40 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KI5310
Sensing range
0.5...24 mm quasi flush
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
M12 Connector
KQ6005
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
0.1 m PVC-Cable; M12 Connector
KI0209
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KT5007
Sensing range
–
Output function
normally open
Output
DC NPN
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KG5301
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG5304
Sensing range
0.5...9 mm quasi flush
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KG5305
Sensing range
0.5...9 mm quasi flush
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KT5309
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KF5002
Sensing range
3...12 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 61 mm
Connection
M12 Connector
KG5302
Sensing range
0.5...30 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M18 x 1 / L = 92.5 mm
Connection
2 m PUR-Cable
KT5010
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
2 m PUR-Cable
KQ6004
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
0.04 m PVC-Cable; M8 Connector
KT5102
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KI5002
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5087
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KQ5101
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.1 m PUR-Cable; M12 Connector
KI0202
Sensing range
3...15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KQ5102
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.04 m PUR-Cable; M8 Connector
KQ5108
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.5 m PUR-Cable; M8 Connector
KQ6002
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable
KI5023
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KI5082
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KT5013
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KT5011
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M8 Connector
KG5065
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 87 mm
Connection
M12 Connector
KI0016
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI0065
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KI0054
Sensing range
5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 90 mm
Connection
1/2" Connector
KT5311
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KD5018
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
105 x 80 x 40 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KI0205
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KT5150
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
2 m PUR-Cable
KT5312
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KB5004
Sensing range
3...20 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KI6003
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
10 m PUR-Cable
KI6004
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M30 x 1.5 / L = 92 mm
Connection
5 m PUR-Cable
KT5151
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 29 / L = 31 mm
Connection
0.3 m PUR-Cable; M12 Connector
KB0025
Sensing range
3...20 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KG5066
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 87 mm
Connection
M12 Connector
KT5012
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
2 m PUR-Cable
KG5071
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 87 mm
Connection
M12 Connector
KT5350
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KT5320
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 32 / L = 31 mm
Connection
2 m PUR-Cable
KT5050
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
2 m PUR-Cable
KI000A
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 150 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KG5045
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI5031
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KQ5006
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.045 m PUR-Cable; M8 Connector
KI0020
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI6002
Sensing range
0.5...40 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
10 m PUR-Cable
KI5052
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 143 mm
Connection
M12 Connector
KI5030
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5038
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 92 mm
Connection
valve plug type A DIN Connector
KG5043
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI5084
Sensing range
8 mm flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KI001A
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 125 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KG5047
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PUR / PVC-Cable
KG5057
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 93.8 mm
Connection
M12 Connector
KQ6003
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
20 x 14 x 48 mm
Connection
0.04 m PVC-Cable; M8 Connector
KF5013
Sensing range
1...6 mm flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M12 x 1 / L = 60 mm
Connection
M12 Connector
KB5062
Sensing range
20 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
Ø 34 / L = 93 mm
Connection
M12 Connector
KI5207
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KD501A
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
105 x 80 x 42 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KI5015
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KG0010
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KB0029
Sensing range
3...20 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KD0009
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
105 x 80 x 40 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KG0009
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI0207
Sensing range
3...15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 mm
Connection
0.1 m PVC-Cable; 1/2" Connector
KG0008
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M18 x 1 / L = 110 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm
KI0206
Sensing range
3...15 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
M30 x 1.5 mm
Connection
0.1 m PVC-Cable; 1/2" Connector
KQ5011
Sensing range
4 mm
Output function
normally open
Output
DC PNP
Dimensions
20 x 7 x 48 mm
Connection
0.76 m PUR-Cable; MOLEX Connector
KG5067
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 77 mm
Connection
2 m PVC-Cable
KG5069
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 77 mm
Connection
2 m PVC-Cable
KI0061
Sensing range
20 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI0040
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 92 mm
Connection
valve plug type A DIN Connector
KI0064
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 90 mm
Connection
1/2" Connector
KQ6006
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable
KG0016
Sensing range
4...24 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M18 x 1 / L = 87 mm
Connection
1/2" Connector
KI5086
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KG5070
Sensing range
8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M18 x 1 / L = 77 mm
Connection
10 m PVC-Cable
KI5019
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KD001A
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
105 x 80 x 42 mm
Connection
terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm
KI0058
Sensing range
20 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
M30 x 1.5 / L = 90 mm
Connection
1/2" Connector
KI5001
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KI5209
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
0.1 m PUR-Cable; M12 Connector
KG5040
Sensing range
2.5...8 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP/NPN
Dimensions
M18 x 1 / L = 110 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm
KI5208
Sensing range
3...15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
2 m PVC-Cable
KG5044
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KD5044
Sensing range
60 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
105 x 80 x 40 mm
Connection
M12 Connector
KD5039
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
105 x 80 x 40 mm
Connection
M12 Connector
KG5041
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M18 x 1 / L = 110 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm
KN5121
Sensing range
–
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 116 mm
Connection
2 m; M12 Connector
KI5081
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC NPN
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KD5022
Sensing range
60 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
120 x 80 x 30 mm
Connection
2 m PVC-Cable
KD0012
Sensing range
60 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
120 x 80 x 30 mm
Connection
2 m PVC-Cable
KG5046
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC NPN
Dimensions
M18 x 1 / L = 84 mm
Connection
2 m PVC-Cable
KI0021
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
AC/DC
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KX5001
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M34 x 1.5 / L = 92 mm
Connection
2 m PVC-Cable
KQ6016
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
20 x 14 x 48 mm
Connection
2 m PVC-Cable; M12 Connector
KI5006
Sensing range
15 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KX5002
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M34 x 1.5 / L = 92 mm
Connection
6 m PVC-Cable
KQ6008
Sensing range
12 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
20 x 14 x 48 mm
Connection
0.04 m PVC-Cable; M8 Connector
KD5019
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC NPN
Dimensions
105 x 80 x 40 mm
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KD0024
Sensing range
60 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
AC/DC
Dimensions
–
Connection
terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm
KF5015
Sensing range
8 mm non-flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 70 mm
Connection
2 m PUR-Cable
KI5090
Sensing range
15 mm non-flush mountable
Output function
normally open / normally closed; (selectable)
Output
DC PNP
Dimensions
M30 x 1.5 / L = 90 mm
Connection
M12 Connector
KI5003
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC PNP
Dimensions
M30 x 1.5 / L = 81 mm
Connection
6 m PVC-Cable
KB0041
Sensing range
3...20 mm non-flush mountable
Output function
normally open
Output
AC/DC
Dimensions
Ø 34 / L = 81 mm
Connection
2 m PVC-Cable
KF5014
Sensing range
4 mm flush mountable
Output function
normally open
Output
DC PNP
Dimensions
M12 x 1 / L = 69 mm
Connection
2 m PUR-Cable
KG5079
Sensing range
8 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M18 x 1 / L = 84 mm
Connection
6 m PVC-Cable
KX5004
Sensing range
15 mm non-flush mountable
Output function
normally closed
Output
DC NAMUR
Dimensions
M34 x 1.5 / L = 92 mm
Connection
20 m PVC-Cable
KT5020
Sensing range
–
Output function
normally open
Output
DC PNP
Dimensions
Ø 96.9 / L = 11 mm
Connection
0.3 m PUR-Cable; M12 Connector