Size | Sensing distance |
Con- necting method *1 |
Body length |
Output config- uration |
Operation mode NO | Operation mode NC | ||
---|---|---|---|---|---|---|---|---|
M8 (Stain- less steel) *2 |
Single | Shielded | 1.5 mm | Pre- wired |
Short | PNP | E2B-S08KS01-WP-B1 2M | E2B-S08KS01-WP-B2 2M |
NPN | E2B-S08KS01-WP-C1 2M | E2B-S08KS01-WP-C2 2M | ||||||
Long | PNP | E2B-S08LS01-WP-B1 2M | E2B-S08LS01-WP-B2 2M | |||||
NPN | E2B-S08LS01-WP-C1 2M | E2B-S08LS01-WP-C2 2M | ||||||
M8 Con- nector (3-pin) |
Short | PNP | E2B-S08KS01-MC-B1 | E2B-S08KS01-MC-B2 | ||||
NPN | E2B-S08KS01-MC-C1 | E2B-S08KS01-MC-C2 | ||||||
Long | PNP | E2B-S08LS01-MC-B1 | E2B-S08LS01-MC-B2 | |||||
NPN | E2B-S08LS01-MC-C1 | E2B-S08LS01-MC-C2 | ||||||
Unshielded | 2 mm | Pre- wired |
Short | PNP | E2B-S08KN02-WP-B1 2M | E2B-S08KN02-WP-B2 2M | ||
NPN | E2B-S08KN02-WP-C1 2M | E2B-S08KN02-WP-C2 2M | ||||||
Long | PNP | E2B-S08LN02-WP-B1 2M | E2B-S08LN02-WP-B2 2M | |||||
NPN | E2B-S08LN02-WP-C1 2M | E2B-S08LN02-WP-C2 2M | ||||||
M8 Con- nector (3-pin) |
Short | PNP | E2B-S08KN02-MC-B1 | E2B-S08KN02-MC-B2 | ||||
NPN | E2B-S08KN02-MC-C1 | E2B-S08KN02-MC-C2 | ||||||
Long | PNP | E2B-S08LN02-MC-B1 | E2B-S08LN02-MC-B2 | |||||
NPN | E2B-S08LN02-MC-C1 | E2B-S08LN02-MC-C2 | ||||||
Double | Shielded | 2 mm | Pre- wired |
Short | PNP | E2B-S08KS02-WP-B1 2M | E2B-S08KS02-WP-B2 2M | |
NPN | E2B-S08KS02-WP-C1 2M | E2B-S08KS02-WP-C2 2M | ||||||
Long | PNP | E2B-S08LS02-WP-B1 2M | E2B-S08LS02-WP-B2 2M | |||||
NPN | E2B-S08LS02-WP-C1 2M | E2B-S08LS02-WP-C2 2M | ||||||
M8 Con- nector (3-pin) |
Short | PNP | E2B-S08KS02-MC-B1 | E2B-S08KS02-MC-B2 | ||||
NPN | E2B-S08KS02-MC-C1 | E2B-S08KS02-MC-C2 | ||||||
Long | PNP | E2B-S08LS02-MC-B1 | E2B-S08LS02-MC-B2 | |||||
NPN | E2B-S08LS02-MC-C1 | E2B-S08LS02-MC-C2 | ||||||
Unshielded | 4 mm | Pre- wired |
Short | PNP | E2B-S08KN04-WP-B1 2M | E2B-S08KN04-WP-B2 2M | ||
NPN | E2B-S08KN04-WP-C1 2M | E2B-S08KN04-WP-C2 2M | ||||||
Long | PNP | E2B-S08LN04-WP-B1 2M | E2B-S08LN04-WP-B2 2M | |||||
NPN | E2B-S08LN04-WP-C1 2M | E2B-S08LN04-WP-C2 2M | ||||||
M8 Con- nector (3-pin) |
Short | PNP | E2B-S08KN04-MC-B1 | E2B-S08KN04-MC-B2 | ||||
NPN | E2B-S08KN04-MC-C1 | E2B-S08KN04-MC-C2 | ||||||
Long | PNP | E2B-S08LN04-MC-B1 | E2B-S08LN04-MC-B2 | |||||
NPN | E2B-S08LN04-MC-C1 | E2B-S08LN04-MC-C2 |
*1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
*2. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).
Size | Sensing distance |
Con- necting method *1 |
Body length |
Output config- uration |
Operation mode NO | Operation mode NC | ||
---|---|---|---|---|---|---|---|---|
M12 (Brass) |
Single | Shielded | 2 mm | Pre- wired |
Short | PNP | E2B-M12KS02-WP-B1 2M | E2B-M12KS02-WP-B2 2M |
NPN | E2B-M12KS02-WP-C1 2M | E2B-M12KS02-WP-C2 2M | ||||||
Long | PNP | E2B-M12LS02-WP-B1 2M | E2B-M12LS02-WP-B2 2M | |||||
NPN | E2B-M12LS02-WP-C1 2M | E2B-M12LS02-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M12KS02-M1-B1 | E2B-M12KS02-M1-B2 | ||||
NPN | E2B-M12KS02-M1-C1 | E2B-M12KS02-M1-C2 | ||||||
Long | PNP | E2B-M12LS02-M1-B1 | E2B-M12LS02-M1-B2 | |||||
NPN | E2B-M12LS02-M1-C1 | E2B-M12LS02-M1-C2 | ||||||
Unshielded | 5 mm | Pre- wired |
Short | PNP | E2B-M12KN05-WP-B1 2M | E2B-M12KN05-WP-B2 2M | ||
NPN | E2B-M12KN05-WP-C1 2M | E2B-M12KN05-WP-C2 2M | ||||||
Long | PNP | E2B-M12LN05-WP-B1 2M | E2B-M12LN05-WP-B2 2M | |||||
NPN | E2B-M12LN05-WP-C1 2M | E2B-M12LN05-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M12KN05-M1-B1 | E2B-M12KN05-M1-B2 | ||||
NPN | E2B-M12KN05-M1-C1 | E2B-M12KN05-M1-C2 | ||||||
Long | PNP | E2B-M12LN05-M1-B1 | E2B-M12LN05-M1-B2 | |||||
NPN | E2B-M12LN05-M1-C1 | E2B-M12LN05-M1-C2 | ||||||
Double | Shielded *2 |
4 mm | Pre- wired |
Short | PNP | E2B-M12KS04-WP-B1 2M | E2B-M12KS04-WP-B2 2M | |
NPN | E2B-M12KS04-WP-C1 2M | E2B-M12KS04-WP-C2 2M | ||||||
Long | PNP | E2B-M12LS04-WP-B1 2M | E2B-M12LS04-WP-B2 2M | |||||
NPN | E2B-M12LS04-WP-C1 2M | E2B-M12LS04-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M12KS04-M1-B1 | E2B-M12KS04-M1-B2 | ||||
NPN | E2B-M12KS04-M1-C1 | E2B-M12KS04-M1-C2 | ||||||
Long | PNP | E2B-M12LS04-M1-B1 | E2B-M12LS04-M1-B2 | |||||
NPN | E2B-M12LS04-M1-C1 | E2B-M12LS04-M1-C2 | ||||||
Unshielded | 8 mm | Pre- wired |
Short | PNP | E2B-M12KN08-WP-B1 2M | E2B-M12KN08-WP-B2 2M | ||
NPN | E2B-M12KN08-WP-C1 2M | E2B-M12KN08-WP-C2 2M | ||||||
Long | PNP | E2B-M12LN08-WP-B1 2M | E2B-M12LN08-WP-B2 2M | |||||
NPN | E2B-M12LN08-WP-C1 2M | E2B-M12LN08-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M12KN08-M1-B1 | E2B-M12KN08-M1-B2 | ||||
NPN | E2B-M12KN08-M1-C1 | E2B-M12KN08-M1-C2 | ||||||
Long | PNP | E2B-M12LN08-M1-B1 | E2B-M12LN08-M1-B2 | |||||
NPN | E2B-M12LN08-M1-C1 | E2B-M12LN08-M1-C2 |
*1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
*2. There are restrictions that apply to Shielded sensors.
Size | Sensing distance |
Con- necting method *1 |
Body length |
Output config- uration |
Operation mode NO | Operation mode NC | ||
---|---|---|---|---|---|---|---|---|
M18 (Brass) |
Single | Shielded | 5 mm | Pre- wired |
Short | PNP | E2B-M18KS05-WP-B1 2M | E2B-M18KS05-WP-B2 2M |
NPN | E2B-M18KS05-WP-C1 2M | E2B-M18KS05-WP-C2 2M | ||||||
Long | PNP | E2B-M18LS05-WP-B1 2M | E2B-M18LS05-WP-B2 2M | |||||
NPN | E2B-M18LS05-WP-C1 2M | E2B-M18LS05-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M18KS05-M1-B1 | E2B-M18KS05-M1-B2 | ||||
NPN | E2B-M18KS05-M1-C1 | E2B-M18KS05-M1-C2 | ||||||
Long | PNP | E2B-M18LS05-M1-B1 | E2B-M18LS05-M1-B2 | |||||
NPN | E2B-M18LS05-M1-C1 | E2B-M18LS05-M1-C2 | ||||||
Unshielded | 10 mm | Pre- wired |
Short | PNP | E2B-M18KN10-WP-B1 2M | E2B-M18KN10-WP-B2 2M | ||
NPN | E2B-M18KN10-WP-C1 2M | E2B-M18KN10-WP-C2 2M | ||||||
Long | PNP | E2B-M18LN10-WP-B1 2M | E2B-M18LN10-WP-B2 2M | |||||
NPN | E2B-M18LN10-WP-C1 2M | E2B-M18LN10-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M18KN10-M1-B1 | E2B-M18KN10-M1-B2 | ||||
NPN | E2B-M18KN10-M1-C1 | E2B-M18KN10-M1-C2 | ||||||
Long | PNP | E2B-M18LN10-M1-B1 | E2B-M18LN10-M1-B2 | |||||
NPN | E2B-M18LN10-M1-C1 | E2B-M18LN10-M1-C2 | ||||||
Double | Shielded *2 |
8 mm | Pre- wired |
Short | PNP | E2B-M18KS08-WP-B1 2M | E2B-M18KS08-WP-B2 2M | |
NPN | E2B-M18KS08-WP-C1 2M | E2B-M18KS08-WP-C2 2M | ||||||
Long | PNP | E2B-M18LS08-WP-B1 2M | E2B-M18LS08-WP-B2 2M | |||||
NPN | E2B-M18LS08-WP-C1 2M | E2B-M18LS08-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M18KS08-M1-B1 | E2B-M18KS08-M1-B2 | ||||
NPN | E2B-M18KS08-M1-C1 | E2B-M18KS08-M1-C2 | ||||||
Long | PNP | E2B-M18LS08-M1-B1 | E2B-M18LS08-M1-B2 | |||||
NPN | E2B-M18LS08-M1-C1 | E2B-M18LS08-M1-C2 | ||||||
Unshielded | 16 mm | Pre- wired |
Short | PNP | E2B-M18KN16-WP-B1 2M | E2B-M18KN16-WP-B2 2M | ||
NPN | E2B-M18KN16-WP-C1 2M | E2B-M18KN16-WP-C2 2M | ||||||
Long | PNP | E2B-M18LN16-WP-B1 2M | E2B-M18LN16-WP-B2 2M | |||||
NPN | E2B-M18LN16-WP-C1 2M | E2B-M18LN16-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M18KN16-M1-B1 | E2B-M18KN16-M1-B2 | ||||
NPN | E2B-M18KN16-M1-C1 | E2B-M18KN16-M1-C2 | ||||||
Long | PNP | E2B-M18LN16-M1-B1 | E2B-M18LN16-M1-B2 | |||||
NPN | E2B-M18LN16-M1-C1 | E2B-M18LN16-M1-C2 |
*1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
*2. There are restrictions that apply to Shielded sensors.
Size | Sensing distance |
Con- necting method *1 |
Body length |
Output config- uration |
Operation mode NO | Operation mode NC | ||
---|---|---|---|---|---|---|---|---|
M30 (Brass) |
Single | Shielded | 10 mm | Pre- wired |
Short | PNP | E2B-M30KS10-WP-B1 2M | E2B-M30KS10-WP-B2 2M |
NPN | E2B-M30KS10-WP-C1 2M | E2B-M30KS10-WP-C2 2M | ||||||
Long | PNP | E2B-M30LS10-WP-B1 2M | E2B-M30LS10-WP-B2 2M | |||||
NPN | E2B-M30LS10-WP-C1 2M | E2B-M30LS10-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M30KS10-M1-B1 | E2B-M30KS10-M1-B2 | ||||
NPN | E2B-M30KS10-M1-C1 | E2B-M30KS10-M1-C2 | ||||||
Long | PNP | E2B-M30LS10-M1-B1 | E2B-M30LS10-M1-B2 | |||||
NPN | E2B-M30LS10-M1-C1 | E2B-M30LS10-M1-C2 | ||||||
Unshielded | 20 mm | Pre- wired |
Short | PNP | E2B-M30KN20-WP-B1 2M | E2B-M30KN20-WP-B2 2M | ||
NPN | E2B-M30KN20-WP-C1 2M | E2B-M30KN20-WP-C2 2M | ||||||
Long | PNP | E2B-M30LN20-WP-B1 2M | E2B-M30LN20-WP-B2 2M | |||||
NPN | E2B-M30LN20-WP-C1 2M | E2B-M30LN20-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M30KN20-M1-B1 | E2B-M30KN20-M1-B2 | ||||
NPN | E2B-M30KN20-M1-C1 | E2B-M30KN20-M1-C2 | ||||||
Long | PNP | E2B-M30LN20-M1-B1 | E2B-M30LN20-M1-B2 | |||||
NPN | E2B-M30LN20-M1-C1 | E2B-M30LN20-M1-C2 | ||||||
Double | Shielded *2 |
15 mm | Pre- wired |
Short | PNP | E2B-M30KS15-WP-B1 2M | E2B-M30KS15-WP-B2 2M | |
NPN | E2B-M30KS15-WP-C1 2M | E2B-M30KS15-WP-C2 2M | ||||||
Long | PNP | E2B-M30LS15-WP-B1 2M | E2B-M30LS15-WP-B2 2M | |||||
NPN | E2B-M30LS15-WP-C1 2M | E2B-M30LS15-WP-C2 2M | ||||||
M12 Con- nector |
Short | PNP | E2B-M30KS15-M1-B1 | E2B-M30KS15-M1-B2 | ||||
NPN | E2B-M30KS15-M1-C1 | E2B-M30KS15-M1-C2 | ||||||
Long | PNP | E2B-M30LS15-M1-B1 | E2B-M30LS15-M1-B2 | |||||
NPN | E2B-M30LS15-M1-C1 | E2B-M30LS15-M1-C2 | ||||||
Unshielded | 30 mm | Pre- wired |
Long | PNP | E2B-M30LN30-WP-B1 2M | E2B-M30LN30-WP-B2 2M | ||
NPN | E2B-M30LN30-WP-C1 2M | E2B-M30LN30-WP-C2 2M | ||||||
M12 Con- nector |
Long | PNP | E2B-M30LN30-M1-B1 | E2B-M30LN30-M1-B2 | ||||
NPN | E2B-M30LN30-M1-C1 | E2B-M30LN30-M1-C2 |
*1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
*2. There are restrictions that apply to Shielded sensors.
Size | Cable | Shape | Cores | Cable length (m) | Model |
---|---|---|---|---|---|
M8 (3-pin) | PVC | Straight | 3 | 2 | XS3F-M8PVC3S2M |
5 | XS3F-M8PVC3S5M | ||||
Right-angle | 2 | XS3F-M8PVC3A2M | |||
5 | XS3F-M8PVC3A5M | ||||
PVC Robot | Straight | 2 | XS3F-M321-302-R | ||
5 | XS3F-M321-305-R | ||||
Right-angle | 2 | XS3F-M322-302-R | |||
5 | XS3F-M322-305-R | ||||
M12 (4-pin) | PVC | Straight | 4 | 2 | XS2F-M12PVC4S2M |
5 | XS2F-M12PVC4S5M | ||||
Right-angle | 2 | XS2F-M12PVC4A2M | |||
5 | XS2F-M12PVC4A5M | ||||
PVC Robot | Straight | 2 | XS2F-D421-D80-F | ||
5 | XS2F-D421-G80-F | ||||
Right-angle | 2 | XS2F-D422-D80-F | |||
5 | XS2F-D422-G80-F |
Size | M8 | ||||
---|---|---|---|---|---|
Sensing distance | Single | Double | |||
Type | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2B-S08[]S01 | E2B-S08[]N02 | E2B-S08[]S02 | E2B-S08[]N04 | |
Sensing distance | 1.5 mm ± 10% | 2 mm ± 10% | 2 mm ± 10% | 4 mm ± 10% | |
Setting distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 1.6 mm | 0 to 3.2 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal.) | ||||
Standard sensing object (mild steel ST37) |
8 × 8 × 1 mm | 8 × 8 × 1 mm | 8 × 8 × 1 mm | 12 × 12 × 1 mm | |
Response frequency *1 | 2,000 Hz | 1,000 Hz | 1,500 Hz | 1,000 Hz | |
Power supply voltage | 10 to 30 VDC. (including 10% ripple (p-p)) | ||||
Current consumption | 10 mA max. | ||||
Output type | -B models: PNP open collector -C models: NPN open collector |
||||
Control output |
Load current *2 | 200 mA max. (30 VDC max.) | |||
Residual voltage | 2 V max. (under load current of 200 mA with cable length of 2 m) | ||||
Indicator | Operation indicator (Yellow LED) | ||||
Operation mode (with sensing object approaching) |
-B1/-C1 models: NO -B2/-C2 models: NC |
||||
Protection circuit | Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
||||
Ambient air temperature | Operation and storage: -25 to 70°C (with no icing or condensation) | ||||
Temperature influence *2 | ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C ±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C |
||||
Ambient humidity | Operation and Storage: 35 to 95% | ||||
Voltage influence | ±1% max. of sensing distance in 24 VDC ±15% | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | 500 m/s2 , 10 times each in X, Y and Z directions | ||||
Standard and listings | (1) IP67 (IEC60529) (2) EMC (EN60947-5-2) | ||||
Connecting method | Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m). Connector models (M8-3pin) |
||||
Weight (packaged) |
Pre-wired model | Short body: Approx. 65 g, Long body: Approx. 65 g | |||
Connector model | Short body: Approx. 20 g, Long body: Approx. 20 g | ||||
Material | Case | Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).) | |||
Sensing surface | PBT | ||||
Cable | Standard cable is 4 mm dia. PVC. | ||||
Clamping nut | Brass-nickel plated | ||||
Toothed washer | Zinc-plated iron |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object between sensing objects, and a setting distance of half the sensing
Size | M12 | ||||
---|---|---|---|---|---|
Sensing distance | Single | Double | |||
Type | Shielded
Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Circuit Breakers (CB) hoạt động thế nào? Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện Tụ chống sét Varistor (MOVs)là gì? Nguyên lý hoạt động (Wiki)Tụ chống sét ( Varistor hoặc Metal Varistor Oxit (MOV)) là một điện trở đặc biệt được sử dụng để bảo vệ mạch điện chống lại sự đột biến điện áp Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào.. Programmable logic controller A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các Sensors In Agriculture (Comming soon)Sensors In Agriculture. Soil moisture sensors, Agricultural temperature sensors, GPS sensors, Weather sensors, Crop health sensors, Electronic sensors, Light 10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)? Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách |