Pepperl Fuchs NCB5-18GM40-N0 | Inductive sensor -Cảm biến tiệm cận cảm ứng 5mm NC NAMUR 2-wire M18 IP66/ IP67

Pepperl Fuchs NCB5-18GM40-N0 | Inductive sensor -Cảm biến tiệm cận cảm ứng 5mm NC NAMUR 2-wire M18 IP66/ IP67

289

Xuất xứ: France

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật
Pepperl Fuchs NCB5-18GM40-N0 | Inductive sensor -Cảm biến tiệm cận cảm ứng 5mm NC NAMUR 2-wire M18 IP66/ IP67

Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Dc (tc): IECEx TUR 21.0018X

- 5 mm flush
- Usable up to SIL 2 acc. to IEC 61508
- NAMUR sensors must be operated with approved switch amplifiers.

 

Datasheet excerpt: Technical data of  NCB5-18GM40-N0

General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 5 mm
Installation flush
Assured operating distance 0 ... 4.05 mm
Actual operating distance 4.5 ... 5.5 mm typ. 5 mm
Reduction factor rAl 0.35
Reduction factor rCu 0.3
Reduction factor r304 0.74
Output type 2-wire
Nominal ratings
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 400 Hz
Hysteresis 1 ... 15 typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Current consumption  
  Measuring plate not detected min. 3 mA
  Measuring plate detected ≤ 1 mA
Switching state indicator all direction LED, yellow
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
MTTFd 2040 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Compliance with standards and directives
Standard conformity  
  NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
  Electromagnetic compatibility NE 21:2007
  Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval  
  Equipment protection level Ga IECEx PTB 11.0037X
  Equipment protection level Gb IECEx PTB 11.0037X
  Equipment protection level Da IECEx PTB 11.0037X
  Equipment protection level Dc (tc) IECEx TUR 21.0018X
  Equipment protection level Mb IECEx PTB 11.0037X
ATEX approval  
  Equipment protection level Ga PTB 00 ATEX 2048 X
  Equipment protection level Gb PTB 00 ATEX 2048 X
  Equipment protection level Da PTB 00 ATEX 2048 X
  Equipment protection level Dc (tc) TÜV 20 ATEX 8524 X
EAC conformity TR CU 012/2011
UL approval  
  Ordinary Location E87056
  Hazardous Location E501628
  Control drawing 116-0452
CCC approval  
  Hazardous Location 2020322315002255
NEPSI approval  
  NEPSI certificate GYJ16.1393X
ANZEx 18.3018X
Marine approval DNVGL TAA00001A5
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type cable
Housing material Stainless steel 1.4305 / AISI 303
Sensing face PBT
Degree of protection IP66 / IP67
Cable  
  Cable diameter 6 mm ± 0.2 mm
  Bending radius > 10 x cable diameter
  Material PVC
  Core cross-section 0.75 mm2
  Length 2 m
General information
Use in the hazardous area see instruction manuals

 

Classifications

System Classcode
ECLASS 10.0.1 27270101
ECLASS 9.0 27270101
ECLASS 8.0 27270101
ECLASS 5.1 27270101
ETIM 7.0 EC002714
ETIM 6.0 EC002714
ETIM 5.0 EC002714
UNSPSC 12.1 39121550

Sản phẩm cùng loại
Gọi điện thoại