Type: RLY3-OSSD200
Part number: 1085344
 

Features

Applications Evaluation unit
Compact sensor types Safety sensors with OSSDs
 

SAFETY-RELATED PARAMETERS

Safety integrity level

SIL3 (IEC 61508)

SILCL3 (IEC 62061)

Category Category 4 (ISO 13849-1)
Performance level PL e (ISO 13849-1)
PFHD (mean probability of a dangerous failure per hour) 1.0 x 10-9
TM (mission time) 20 years (ISO 13849-1)
Safe state in the event of a fault The N/O is open; in other words, the safety-related enabling current paths are interrupted.
Stop category 0 (IEC 60204-1)
 

FUNCTIONS

Sensor monitoring Sequence monitoring
Restart interlock
Reset

Automatic

Manual

External device monitoring (EDM)
 

INTERFACES

Connection type Front connector with spring terminals
Inputs

2 safety inputs

1 input for reset pushbutton or external device monitoring (EDM)

Outputs

2 enabling current paths (safe)

2 application diagnostic outputs (not safe)

1 test pulse output (not safe)

Display elements LEDs
Configuration method Hard wired
 

ELECTRICAL DATA - OPERATING DATA

Voltage supply PELV or SELV
Supply voltage VS 24 V DC (16.8 V ... 30 V)
Residual ripple ≤ 2.4 V
Power consumption ≤ 2.5 W (DC)
 

ELECTRICAL DATA - SAFETY INPUTS

Number 2
Input voltage  
HIGH 24 V DC (11 V ... 30 V)
LOW 0 V DC (–3 V ... 5 V)
Input current 4 mA ... 6 mA
Test pulse width ≤ 1 ms
Test pulse rate ≤ 10 Hz
 

ELECTRICAL DATA - RESET PUSHBUTTON OR EXTERNAL DEVICE MONITORING (EDM) INPUT

Number 1
Input voltage  
HIGH 24 V DC (11 V ... 30 V)
LOW 0 V DC (–3 V ... 5 V)
Input current 4 mA ... 6 mA
 

ELECTRICAL DATA - ENABLING CURRENT PATHS

Response time 10 ms
Number 2
Type of output N/O contacts, positively guided
Contact material Silver alloy, gold flashed
Switching voltage

10 V AC ... 230 V AC

10 V DC ... 230 V DC

Switching current 10 mA ... 6 A
Total current 12 A
Mechanical life 10,000,000 Schaltspiele
Overvoltage category III (EN 60664-1)
Rated impulse withstand voltage Uimp 6 kV (EN 60664-1)
 

ELECTRICAL DATA - APPLICATION DIAGNOSTIC OUTPUTS

Number 2
Type of output Push-pull semiconductor output, short-circuit protected
Output voltage  
HIGH ≥ Vs – 3 V
LOW ≤ 3 V
Input current (NPN) ≤ 15 mA
Output current (PNP) ≤ 120 mA
 

ELECTRICAL DATA - TEST PULSE OUTPUTS

Number 1
Type of output PNP semiconductors, short-circuit protected
Output voltage ≥ Vs – 3 V
Test pulse width 2 ms
Test pulse interval 40 ms
 

MECHANICAL DATA

Dimensions (W x H x D) 18 mm x 124.6 mm x 85.5 mm
Weight 130 g
 

AMBIENT DATA

Enclosure rating IP20 (IEC 60529)
Ambient operating temperature –25 °C ... +55 °C
Storage temperature –25 °C ... +70 °C
Air humidity 10 % ... 95 %, Non-condensing
Interference emission According to IEC 61000-6-4
Interference resistance

According to IEC 61326-3-1

According to IEC 61000-6-2

According to IEC 60947-5-1

 

CLASSIFICATIONS

ECl@ss 5.0 27371990
ECl@ss 5.1.4 27371990
ECl@ss 6.0 27371819
ECl@ss 6.2 27371819
ECl@ss 7.0 27371819
ECl@ss 8.0 27371819
ECl@ss 8.1 27371819
ECl@ss 9.0 27371819
ECl@ss 10.0 27371819
ECl@ss 11.0 27371819
ETIM 5.0 EC001449
ETIM 6.0 EC001449
ETIM 7.0 EC001449
UNSPSC 16.0901 41113704
 

Technical drawings

Sick RLY3-OSSD200, part number 1085344 Safety relays Rờ le an toàn NO 24VDC 12A 4-6mA
Dimensional drawing EMSS1, HAND1, OSSD1, OSSD2, TIME1

Sick RLY3-OSSD200, part number 1085344 Safety relays Rờ le an toàn NO 24VDC 12A 4-6mA
RLY3-OSSD2 at safety light curtain with manual reset and external device monitoring

Sick RLY3-OSSD200, part number 1085344 Safety relays Rờ le an toàn NO 24VDC 12A 4-6mA
RLY3-OSSD2 at safety light curtain with automated reset and external device monitoring

 

- Xem chi tiết Tài liệu kỹ thuật/ Datasheet Safety relays RLY3-OSSD200 (1085344) Sick



 

Tham khảo thêm các models Safety relay khác thuộc dòng RLY3

Type: RLY3-HAND100

Part number: 1085346
- Product family: ReLy
- Product family group: Safety relays
- Applications: Evaluation unit
- Compact sensor types: Two-hand controls Type III C, in accordance with EN 574
- Connection type: Front connector with spring terminals
- Restart interlock: no
- External device monitoring (EDM): Integrated
- Outputs: 2 enabling current paths (safe), 1 application diagnostic output (not safe)
- Housing width: 18 mm
 

Type: RLY3-EMSS100

Part number: 1085345
- Product family: ReLy
- Product family group: Safety relays
- Applications: Evaluation unit
- Compact sensor types: Safety sensors with potential-free outputs
- Connection type: Front connector with spring terminals
- Restart interlock: yes
- External device monitoring (EDM): Integrated
- Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
- Housing width: 18 mm
 

Type: RLY3-OSSD100

Part number: 1085343
- Product family: ReLy, Flexi Soft
- Product family group: Safety controllers, Safety relays
- Applications: Output expansion module for OSSDs
- Compact sensor types: Safety sensors with OSSDs
- Connection type: Front connector with spring terminals
- Restart interlock: no
- External device monitoring (EDM): Via path
- Outputs: 2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe)
- Housing width: 18 mm
 

Type: RLY3-OSSD200

Part number: 1085344
- Product family: ReLy
- Product family group: Safety relays
- Applications: Evaluation unit
- Compact sensor types: Safety sensors with OSSDs
- Connection type: Front connector with spring terminals
- Restart interlock: yes
- External device monitoring (EDM): Integrated
- Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
- Housing width: 18 mm
 

Type: RLY3-OSSD300

Part number: 1099969
- Product family: ReLy
- Product family group: Safety relays
- Applications: Evaluation unit
- Compact sensor types: Safety sensors with OSSDs
- Connection type: Front connector with spring terminals
- Restart interlock: yes
- External device monitoring (EDM): Integrated
- Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
- Housing width: 18 mm
 

Type: RLY3-TIME100

Part number: 1100688
- Product family: ReLy
- Product family group: Safety relays
- Applications: Evaluation unit for stop category 1 applications
- Compact sensor types: Safety sensors with OSSDs, safety sensors with potential-free outputs
- Connection type: Front connector with spring terminals
- Restart interlock: yes
- External device monitoring (EDM): Integrated
- Outputs: 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
- Housing width: 18 mm
 

Type: RLY3-OSSD400

Part number: 1099971
- Product family: ReLy, Flexi Soft
- Product family group: Safety controllers, Safety relays
- Applications: Output expansion module for OSSDs
- Compact sensor types: Safety sensors with OSSDs
- Connection type: Front connector with spring terminals
- Restart interlock: no
- External device monitoring (EDM): Via path
- Outputs: 4 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe), 1 signaling current path (not safe)
- Housing width: 28 mm
 

Type: RLY3-EMSS300

Part number: 1099973
- Product family: ReLy
- Product family group: Safety relays
- Applications: Evaluation unit
- Compact sensor types: Safety sensors with potential-free outputs
- Connection type: Front connector with spring terminals
- Restart interlock: yes
- External device monitoring (EDM): Integrated
- Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
- Housing width: 18 mm