Chi tiết thông tin đặc tính sản phẩm
Rờ le an toàn Sick Safety relays UE403 UE403-A0930 (1026287)
Type:UE403-A0930
Part number: 1026287
SAFETY-RELATED PARAMETERS
| Safety integrity level |
SIL3 (IEC 61508)
SILCL3 (EN 62061)
|
| Category |
Category 4 (EN ISO 13849) |
| Performance level |
PL e (EN ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) |
1.0 x 10-8 (EN ISO 13849) 1) |
| TM (mission time) |
20 years (EN ISO 13849) 1) |
1) Only in conjunction with M4000 Advanced, M4000 Advanced A/P and M4000 Advanced Curtain.
FUNCTIONS
| Concurrence monitoring |
✔ |
| Monitoring of total muting time |
✔ |
| Sensor gap monitoring |
✔ |
| Belt stop |
✔ |
| Muting with override |
✔ |
| Exit monitoring |
✔ |
| End of muting by ESPE |
✔ |
INTERFACES
| Connection type |
Female connector M12, 5-pin |
ELECTRICAL DATA
| Protection class |
III (IEC 61140) |
| Supply voltage VS |
24 V DC (19.2 V DC ... 28.8 V DC) 1) |
| Power consumption |
≤ 2 A |
| Inputs: override, reset, C1, belt stop, muting sensors |
|
| ON state, switching voltage HIGH |
24 V DC (11 V DC ... 30 V DC) |
| OFF state, switching voltage LOW |
0 V DC (–30 V DC ... 5 V DC) |
| Input current HIGH |
6 mA ... 15 mA |
| Input current LOW |
–0.5 mA ... 1.5 mA |
|
| Outputs: voltage supply for reset, override, C1 |
|
| Supply voltage |
24 V DC (15 V DC ... 28.8 V DC) |
| Output current |
≤ 400 mA 2) |
|
| Outputs: muting sensors |
|
| Supply voltage |
24 V DC (15 V DC ... 28.8 V DC) |
| Output current |
≤ 500 mA 2) |
|
| Muting lamp |
|
| Output current HIGH (monitored) |
20 mA ... 400 mA 3) |
| Output current HIGH (not monitored) |
0 mA ... 400 mA 3) |
|
1) Via connected ESPE.
2) Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1 in each case): max. 1000 mA.
3) At max. 5 W power consumption.
MECHANICAL DATA
| Dimensions (W x H x D) |
76.5 mm x 225.2 mm x 40 mm |
| Weight |
+ 600 g |
| Mounting |
Flexible mounting on the M4000 Advanced or directly in the system |
AMBIENT DATA
| Enclosure rating |
IP65 (IEC 60529) |
| Ambient operating temperature |
–30 °C ... +55 °C |
| Storage temperature |
–30 °C ... +70 °C |
CLASSIFICATIONS
| ECl@ss 5.0 |
27371990 |
| ECl@ss 5.1.4 |
27371990 |
| ECl@ss 6.0 |
27371819 |
| ECl@ss 6.2 |
27371819 |
| ECl@ss 7.0 |
27371819 |
| ECl@ss 8.0 |
27371819 |
| ECl@ss 8.1 |
27371819 |
| ECl@ss 9.0 |
27371819 |
| ECl@ss 10.0 |
27371819 |
| ECl@ss 11.0 |
27371819 |
| ETIM 5.0 |
EC001449 |
| ETIM 6.0 |
EC001449 |
| ETIM 7.0 |
EC001449 |
| UNSPSC 16.0901 |
41113704 |
Technical drawings

Dimensional drawing UE403 muting switching amplifier