Product characteristics/function |
Performance features/benefits |
Hybrid switching devices and three-phase motor control |
Minimum power loss and optimum/symmetrical motor control |
TIA Integration – communication modules and HMI modules optional |
Efficient configuration and maximum flexibility in automation engineering |
Soft Torque |
Reduced mechanical loading and optimum pump stop |
Parameterization using potentiometers |
Simple and fast commissioning |
Wide range for control supply and main voltage |
Low variance, high system availability even with weak supply networks |
Type |
|
3RW5213 |
3RW5214 |
3RW5215 |
3RW5216 |
3RW5217 |
---|---|---|---|---|---|---|
Rated operational current Ie |
A |
13 |
18 |
25 |
32 |
38 |
Power electronics |
||||||
Load rating rated operational current Ie |
|
|
||||
IEC + UL/CSA individual mounting at 40/50/60 °C, AC‑53a |
A |
13/11.5/10.5 |
18/15.9/13.8 |
25/22.3/19.6 |
32/28.4/26 |
38/33.5/30.5 |
Permissible rated motor current and starts/h |
||||||
Normal starting (CLASS 10A) |
|
|
||||
Rated motor current IM; Tu = 40/50/60 °C |
A |
13/11.5/10.5 |
18/15.9/13.8 |
25/22.3/19.6 |
32/28.4/26 |
38/33.5/30.5 |
|
|
|
||||
|
1/h |
43 |
43 |
43 |
43 |
43 |
|
1/h |
18 |
18 |
18 |
18 |
18 |
|
|
|
||||
|
1/h |
28 |
28 |
28 |
28 |
28 |
|
1/h |
10 |
10 |
10 |
10 |
10 |
Normal starting (CLASS 10E) |
|
|
||||
Rated motor current IM; Tu = 40/50/60 °C |
A |
13/11.5/10.5 |
18/15.9/13.8 |
25/22.3/19.6 |
32/28.4/26 |
38/33.5/30.5 |
|
|
|
||||
|
1/h |
21 |
21 |
21 |
21 |
21 |
|
1/h |
8 |
8 |
8 |
8 |
8 |
|
|
|
||||
|
1/h |
13 |
13 |
13 |
13 |
13 |
|
1/h |
4 |
4 |
4 |
4 |
4 |
Heavy startup (CLASS 20E) |
|
|
||||
Rated motor current IM; Tu = 40/50/60 °C |
A |
13/11.5/10.5 |
18/15.9/13.8 |
25/22.3/19.6 |
29.6/27.2/23.6 |
33.5/30.5/27.5 |
|
|
|
||||
|
1/h |
10 |
10 |
10 |
10 |
10 |
|
1/h |
4 |
4 |
4 |
4 |
4 |
|
|
|
||||
|
1/h |
7 |
7 |
7 |
7 |
7 |
|
1/h |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
Adjustable rated motor current IM |
|
|
||||
|
A |
5.5/13 |
7.5/18 |
11.5/25 |
14/32 |
15.5/38 |
|
A |
9.5/22.5 |
13/31.2 |
19.9/43.3 |
24.2/55.4 |
26.8/65.8 |
Type |
|
3RW5224 |
3RW5225 |
3RW5226 |
3RW5227 |
---|---|---|---|---|---|
Rated operational current Ie |
A |
47 |
63 |
77 |
93 |
Power electronics |
|||||
Load rating rated operational current Ie |
|
|
|||
IEC + UL/CSA individual mounting at 40/50/60 °C, AC‑53a |
A |
47/41.6/36.2 |
63/55.5/50.5 |
77/68/62 |
93/82.5/75.5 |
Permissible rated motor current and starts/h |
|||||
Normal starting (CLASS 10A) |
|
|
|||
Rated motor current IM; Tu = 40/50/60 °C |
A |
47/41.6/36.2 |
63/55.5/50.5 |
77/68/62 |
93/82.5/75.5 |
|
|
|
|||
|
1/h |
43 |
43 |
43 |
43 |
|
1/h |
18 |
18 |
18 |
18 |
|
|
|
|||
|
1/h |
28 |
28 |
28 |
28 |
|
1/h |
10 |
10 |
10 |
10 |
Normal starting (CLASS 10E) |
|
|
|||
Rated motor current IM; Tu = 40/50/60 °C |
A |
47/41.6/36.2 |
63/55.5/50.5 |
77/68/62 |
93/82.5/75.5 |
|
|
|
|||
|
1/h |
21 |
21 |
21 |
21 |
|
1/h |
8 |
8 |
8 |
8 |
|
|
|
|||
|
1/h |
13 |
13 |
13 |
13 |
|
1/h |
4 |
4 |
4 |
4 |
Heavy startup (CLASS 20E) |
|
|
|||
Rated motor current IM; Tu = 40/50/60 °C |
A |
47/41.6/36.2 |
63/55.5/50.5 |
65/59/53 |
93/82.5/75.5 |
|
|
|
|||
|
1/h |
10 |
10 |
10 |
10 |
|
1/h |
4 |
3 |
4 |
4 |
|
|
|
|||
|
1/h |
7 |
4 |
7 |
7 |
|
1/h |
2 |
0 |
2.5 |
2.5 |
Adjustable rated motor current IM |
|
|
|||
|
A |
20/47 |
25.5/63 |
32/77 |
40.5/93 |
|
A |
34.6/81.4 |
44.2/109 |
55.4/133 |
70.1/161 |
Type |
|
3RW5234 |
3RW5235 |
3RW5236 |
---|---|---|---|---|
Rated operational current Ie |
A |
113 |
143 |
171 |
Power electronics |
||||
Load rating rated operational current Ie |
|
|
||
IEC + UL/CSA individual mounting at 40/50/60 °C, AC‑53a |
A |
113/101/89 |
143/128/118 |
171/153/141 |
Permissible rated motor current and starts/h |
||||
Normal starting (CLASS 10A) |
|
|
||
Rated motor current IM; Tu = 40/50/60 °C |
A |
113/101/89 |
143/128/118 |
171/153/141 |
|
|
|
||
|
1/h |
43 |
43 |
43 |
|
1/h |
18 |
18 |
18 |
|
|
|
||
|
1/h |
28 |
27 |
20 |
|
1/h |
10 |
8 |
4 |
Normal starting (CLASS 10E) |
|
|
||
Rated motor current IM; Tu = 40/50/60 °C |
A |
113/101/89 |
139/127/116 |
158/146/129 |
|
|
|
||
|
1/h |
21 |
21 |
21 |
|
1/h |
8 |
8 |
8 |
|
|
|
||
|
1/h |
13 |
12 |
12 |
|
1/h |
4 |
1 |
1 |
Heavy startup (CLASS 20E) |
|
|
||
Rated motor current IM; Tu = 40/50/60 °C |
A |
109/97/85 |
113/103/93 |
129/117/105 |
|
|
|
||
|
1/h |
10 |
10 |
10 |
|
1/h |
4 |
4 |
4 |
|
|
|
||
|
1/h |
7 |
7 |
7 |
|
1/h |
2.5 |
2.5 |
2.5 |
Adjustable rated motor current IM |
|
|
||
|
A |
53/113 |
68/143 |
81/171 |
|
A |
91.8/195 |
118/248 |
140/296 |
Type |
|
3RW5243 |
3RW5244 |
3RW5245 |
3RW5246 |
3RW5247 |
3RW5248 |
---|---|---|---|---|---|---|---|
Rated operational current Ie |
A |
210 |
250 |
315 |
370 |
470 |
570 |
Power electronics |
|||||||
Load rating rated operational current Ie |
|
|
|||||
IEC + UL/CSA individual mounting at 40/50/60 °C, AC‑53a |
A |
210/186/170 |
250/220/200 |
315/279/255 |
370/328/300 |
470/416/380 |
570/504/460 |
Permissible rated motor current and starts/h |
|||||||
Normal starting (CLASS 10A) |
|
|
|||||
Rated motor current IM; Tu = 40/50/60 °C |
A |
210/186/170 |
250/220/200 |
315/279/255 |
370/328/300 |
470/416/380 |
570/504/460 |
|
|
|
|||||
|
1/h |
43 |
43 |
43 |
43 |
30 |
20 |
|
1/h |
18 |
18 |
14 |
18 |
11 |
6 |
|
|
|
|||||
|
1/h |
28 |
28 |
16 |
28 |
17 |
9 |
|
1/h |
5 |
10 |
4 |
10 |
5 |
1 |
Normal starting (CLASS 10E) |
|
|
|||||
Rated motor current IM; Tu = 40/50/60 °C |
A |
197/184/170 |
250/220/200 |
279/255/231 |
370/328/300 |
398/362/326 |
460/416/372 |
|
|
|
|||||
|
1/h |
21 |
21 |
21 |
21 |
21 |
18 |
|
1/h |
8 |
8 |
8 |
8 |
8 |
7 |
|
|
|
|||||
|
1/h |
12 |
13 |
12 |
13 |
13 |
11 |
|
1/h |
1 |
4 |
3 |
4 |
4 |
2 |
Heavy startup (CLASS 20E) |
|
|
|||||
Rated motor current IM; Tu = 40/50/60 °C |
A |
162/146/130 |
200/180/160 |
195/171/147 |
258/230/202 |
272/236/218 |
284/262/240 |
|
|
|
|||||
|
1/h |
10 |
10 |
10 |
10 |
10 |
10 |
|
1/h |
4 |
4 |
4 |
4 |
4 |
4 |
|
|
|
|||||
|
1/h |
7 |
7 |
7 |
7 |
7 |
7 |
|
1/h |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
Adjustable rated motor current IM |
|
|
|||||
|
A |
90/210 |
100/250 |
135/315 |
160/370 |
200/470 |
240/570 |
|
A |
156/364 |
173/433 |
234/546 |
277/641 |
346/814 |
416/987 |
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations on the setup of motor feeders with soft starters, see "SIRIUS 3RW soft starters" → "Overview" → "Motor feeders with soft starters".
3RW5213 |
3RV2032-4TA10 |
65 |
3RV2032-4TA10 |
18 |
3RV2032-4DA10 |
65 |
3RV2032-4DA10 |
18 |
3RW5214 |
3RV2032-4DA10 |
65 |
3RV2032-4DA10 |
15 |
3RV2032-4EA10 |
65 |
3RV2032-4EA10 |
15 |
3RW5215 |
3RV2032-4EA10 |
65 |
3RV2032-4EA10 |
15 |
3RV2032-4VA10 |
65 |
3RV2032-4VA10 |
15 |
3RW5216 |
3RV2032-4VA10 |
65 |
3RV2032-4VA10 |
10 |
3RV2032-4JA10 |
65 |
3RV2032-4JA10 |
10 |
3RW5217 |
3RV2032-4WA10 |
65 |
3RV2032-4WA10 |
10 |
3RV2032-4RA10 |
65 |
3RV2032-4RA10 |
10 |
3RW5224 |
3RV2032-4JA10 |
65 |
3RV2032-4JA10 |
10 |
3RV2032-4RA10 |
65 |
3RV2032-4RA10 |
10 |
3RW5225 |
3VA2163-7MN32-0AA0 |
65 |
3VA2163-7MN32-0AA0 |
20 |
3VA2110-7MN32-0AA0 |
65 |
3VA2110-7MN32-0AA0 |
20 |
3RW5226 |
3VA2110-7MN32-0AA0 |
65 |
3VA2110-7MN32-0AA0 |
20 |
3VA2216-7MN32-0AA0 |
65 |
3VA2216-7MN32-0AA0 |
20 |
3RW5227 |
3VA2216-7MN32-0AA0 |
15 |
3VA2216-7MN32-0AA0 |
10 |
3VA2220-7MN32-0AA0 |
15 |
3VA2220-7MN32-0AA0 |
10 |
3RW5234 |
3VA2216-7MN32-0AA0 |
65 |
-- |
-- |
3VA2220-7MN32-0AA0 |
65 |
-- |
-- |
3RW5235 |
3VA2220-7MN32-0AA0 |
65 |
-- |
-- |
3VA2325-7MN32-0AA0 |
65 |
-- |
-- |
3RW5236 |
3VA2325-7MN32-0AA0 |
30 |
3VA2325-7MN32-0AA0 |
10 |
3VA2440-7MN32-0AA0 |
30 |
3VA2440-7MN32-0AA0 |
10 |
3RW5243 |
3VA2325-7MN32-0AA0 |
65 |
3VA2325-7MN32-0AA0 |
65 |
3VA2440-7MN32-0AA0 |
65 |
3VA2440-7MN32-0AA0 |
65 |
3RW5244 |
3VA2440-7MN32-0AA0 |
65 |
3VA2440-7MN32-0AA0 |
65 |
3VA2450-7MN32-0AA0 |
65 |
3VA2450-7MN32-0AA0 |
65 |
3RW5245 |
3VA2440-7MN32-0AA0 |
65 |
3VA2440-7MN32-0AA0 |
65 |
3VA2580-6HN32-0AA0 |
65 |
3VA2580-6HN32-0AA0 |
65 |
3RW5246 |
3VA2440-7MN32-0AA0 |
65 |
3VA2440-7MN32-0AA0 |
65 |
3VA2580-6HN32-0AA0 |
65 |
3VA2580-6HN32-0AA0 |
65 |
3RW5247 |
3VA2450-7MN32-0AA0 |
65 |
3VA2450-7MN32-0AA0 |
65 |
3VA2510-6HN32-0AA0 |
65 |
3VA2510-6HN32-0AA0 |
65 |
3RW5248 |
3VA2580-6HN32-0AA0 |
65 |
3VA2580-6HN32-0AA0 |
65 |
3VA2510-6HN32-0AA0 |
65 |
3VA2510-6HN32-0AA0 |
65 |
Note:
The service factor or measurement inaccuracies have been taken into account, for example, for the selection of the specified motor starter protectors/circuit breakers; the specified short-circuit breaking capacities Iq in kA are covered by combination tests. Smaller motor starter protectors/circuit breakers from the same series can be used at any time as smaller ones trip more quickly in the event of a short circuit (unchanged short-circuit breaking capacity) and thus protect the soft starter in any case. The dimensioning of the short-circuit components must match the connected three-phase motor, the short-circuit and overload requirements of the application, and the line protection for the cables used.
gG class full-range fuses for cable and line protection
according to IEC 60269‑2, without semiconductor protection
Type of coordination "1", short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations on the setup of motor feeders with soft starters, see "SIRIUS 3RW soft starters" → "Overview" → "Motor feeders with soft starters".
3RW5213 |
3NA3820-6 |
3RT2025 |
3RT2025 |
3NA3820-6 |
3RT2027 |
3RT2035 |
3RT2025 |
3RT2025 |
3RW5214 |
3NA3820-6 |
3RT2026 |
3RT2027 |
3NA3820-6 |
3RT2027 |
3RT2037 |
3RT2026 |
3RT2027 |
3RW5215 |
3NA3822-6 |
3RT2027 |
3RT2037 |
3NA3822-6 |
3RT2036 |
3RT2037 |
3RT2027 |
3RT2037 |
3RW5216 |
3NA3824-6 |
3RT2035 |
3RT2037 |
3NA3824-6 |
3RT2037 |
3RT2038 |
3RT2035 |
3RT2037 |
3RW5217 |
3NA3824-6 |
3RT2035 |
3RT2037 |
3NA3824-6 |
3RT2038 |
3RT2046 |
3RT2035 |
3RT2037 |
3RW5224 |
3NA3824-6 |
3RT2036 |
3RT2037 |
3NA3824-6 |
3RT2046 |
3RT2047 |
3RT2036 |
3RT2037 |
3RW5225 |
3NA3830-6 |
3RT2037 |
3RT2046 |
3NA3830-6 |
3RT2047 |
3RT1054 |
3RT2037 |
3RT2046 |
3RW5226 |
3NA3132-6 |
3RT2038 |
3RT2046 |
3NA3132-6 |
3RT1055 |
3RT1055 |
3RT2038 |
3RT2046 |
3RW5227 |
3NA3136-6 |
3RT2046 |
3RT2047 |
3NA3136-6 |
3RT1056 |
3RT1056 |
3RT2046 |
3RT2047 |
3RW5234 |
3NA3244-6 |
3RT1054 |
3RT1054 |
3NA3244-6 |
3RT1064 |
3RT1064 |
3RT1054 |
3RT1054 |
3RW5235 |
3NA3244-6 |
3RT1055 |
3RT1055 |
3NA3244-6 |
3RT1065 |
3RT1065 |
3RT1055 |
3RT1055 |
3RW5236 |
3NA3365-6 |
3RT1056 |
3RT1064 |
3NA3365-6 |
3RT1066 |
3RT1075 |
3RT1056 |
3RT1064 |
3RW5243 |
2 x 3NA3354-6 |
3RT1064 |
3RT1064 |
2 x 3NA3354-6 |
3RT1075 |
3RT1075 |
3RT1064 |
3RT1064 |
3RW5244 |
2 x 3NA3354-6 |
3RT1065 |
3RT1065 |
2 x 3NA3354-6 |
3RT1076 |
3RT1076 |
3RT1065 |
3RT1065 |
3RW5245 |
2 x 3NA3365-6 |
3RT1075 |
3RT1075 |
2 x 3NA3365-6 |
3TF68 |
3TF68 |
3RT1075 |
3RT1075 |
3RW5246 |
2 x 3NA3365-6 |
3RT1075 |
3RT1075 |
2 x 3NA3365-6 |
3TF69 |
3TF69 |
3RT1075 |
3RT1075 |
3RW5247 |
2 x 3NA3365-6 |
3RT1076 |
3RT1276 |
2 x 3NA3365-6 |
3TF69 |
3TF69 |
3RT1076 |
3RT1276 |
3RW5248 |
2 x 3NA3365-6 |
3TF68 |
3TF68 |
2 x 3NA3365-6 |
-- |
-- |
3TF68 |
3TF68 |
Note:
The specified short-circuit breaking capacities Iq in kA are covered by combination tests. Smaller fuses than those specified can be used at any time as smaller ones trip more quickly in the event of a short circuit (unchanged short-circuit breaking capacity) and thus protect the soft starter in any case. The dimensioning of the short-circuit components must, however, be suitable for the connected three-phase motor and the line protection for the cables used.
gR class full-range fuses for semiconductor protection,
cable and line protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations on the setup of motor feeders with soft starters, see "SIRIUS 3RW soft starters" → "Overview" → "Motor feeders with soft starters".
3RW5213 |
3NE1815-0 |
3RT2025 |
3RT2025 |
3RW5214 |
3NE1802-0 |
3RT2026 |
3RT2027 |
3RW5215 |
3NE1817-0 |
3RT2027 |
3RT2037 |
3RW5216 |
3NE1818-0 |
3RT2035 |
3RT2037 |
3RW5217 |
3NE1820-0 |
3RT2035 |
3RT2037 |
3RW5224 |
3NE1021-2 |
3RT2036 |
3RT2037 |
3RW5225 |
3NE1022-0 |
3RT2037 |
3RT2046 |
3RW5226 |
3NE1224-0 |
3RT2038 |
3RT2046 |
3RW5227 |
3NE1224-0 |
3RT2046 |
3RT2047 |
3RW5234 |
3NE1225-0 |
3RT1054 |
3RT1054 |
3RW5235 |
3NE1227-0 |
3RT1055 |
3RT1055 |
3RW5236 |
3NE1230-0 |
3RT1056 |
3RT1064 |
3RW5243 |
3NE1230-21) |
3RT1064 |
3RT1064 |
3RW5244 |
3NE1331-0 |
3RT1065 |
3RT1065 |
3RW5245 |
3NE1334-2 |
3RT1075 |
3RT1075 |
3RW5246 |
3NE1334-2 |
3RT1075 |
3RT1075 |
3RW5247 |
3NE1436-2 |
3RT1076 |
3RT1276 |
3RW5248 |
3NE1437-2 |
3TF68 |
3TF68 |
1) Only for systems up to 500 V.
Note:
The specified short-circuit breaking capacities Iq in kA are covered by combination tests. Smaller fuses than those specified can be used at any time as smaller ones trip more quickly in the event of a short circuit (unchanged short-circuit breaking capacity) and thus protect the soft starter in any case. The dimensioning of the short-circuit components must, however, be suitable for the connected three-phase motor and the line protection for the cables used.
In inside-delta circuits, a gR class full-range fuse could not provide the semiconductor protection of the delta-connected soft starter with a short-circuit breaking capacity that is adequate for practical use. In this case, we recommend using aR class partial-range fuses for semiconductor protection for type of coordination "2", see next table.
aR class partial-range fuses for semiconductor protection
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations on the setup of motor feeders with soft starters, see "SIRIUS 3RW soft starters" → "Overview" → "Motor feeders with soft starters".
3RW5213 |
3NA3820-6 |
3NE8017-1 |
3RT2025 |
3RT2025 |
3NA3820-6 |
3NE8017-1 |
3RT2027 |
3RT2035 |
3RT2025 |
3RT2025 |
3RW5214 |
3NA3820-6 |
3NE8020-1 |
3RT2026 |
3RT2027 |
3NA3820-6 |
3NE8020-1 |
3RT2027 |
3RT2037 |
3RT2026 |
3RT2027 |
3RW5215 |
3NA3822-6 |
3NE8021-1 |
3RT2027 |
3RT2037 |
3NA3822-6 |
3NE8021-1 |
3RT2036 |
3RT2037 |
3RT2027 |
3RT2037 |
3RW5216 |
3NA3824-6 |
3NE8022-1 |
3RT2035 |
3RT2037 |
3NA3824-6 |
3NE8022-1 |
3RT2037 |
3RT2038 |
3RT2035 |
3RT2037 |
3RW5217 |
3NA3824-6 |
3NE8024-1 |
3RT2035 |
3RT2037 |
3NA3824-6 |
3NE8024-1 |
3RT2038 |
3RT2046 |
3RT2035 |
3RT2037 |
3RW5224 |
3NA3824-6 |
3NE8024-1 |
3RT2036 |
3RT2037 |
3NA3824-6 |
3NE8024-1 |
3RT2046 |
3RT2047 |
3RT2036 |
3RT2037 |
3RW5225 |
3NA3830-6 |
3NE8024-1 |
3RT2037 |
3RT2046 |
3NA3830-6 |
3NE8024-1 |
3RT2047 |
3RT1054 |
3RT2037 |
3RT2046 |
3RW5226 |
3NA3132-6 |
3NE8024-1 |
3RT2038 |
3RT2046 |
3NA3132-6 |
3NE8024-1 |
3RT1055 |
3RT1055 |
3RT2038 |
3RT2046 |
3RW5227 |
3NA3136-6 |
3NE4124 |
3RT2046 |
3RT2047 |
3NA3136-6 |
3NE4124 |
3RT1056 |
3RT1056 |
3RT2046 |
3RT2047 |
3RW5234 |
3NA3244-6 |
3NE3332-0B |
3RT1054 |
3RT1054 |
3NA3244-6 |
3NE3332-0B |
3RT1064 |
3RT1064 |
3RT1054 |
3RT1054 |
3RW5235 |
3NA3244-6 |
3NE3334-0B |
3RT1055 |
3RT1055 |
3NA3244-6 |
3NE3334-0B |
3RT1065 |
3RT1065 |
3RT1055 |
3RT1055 |
3RW5236 |
3NA3365-6 |
3NE3335 |
3RT1056 |
3RT1064 |
3NA3365-6 |
3NE3335 |
3RT1066 |
3RT1075 |
3RT1056 |
3RT1064 |
3RW5243 |
2 x 3NA3354-6 |
3NE3333 |
3RT1064 |
3RT1064 |
2 x 3NA3354-6 |
3NE3333 |
3RT1075 |
3RT1075 |
3RT1064 |
3RT1064 |
3RW5244 |
2 x 3NA3354-6 |
3NE3336 |
3RT1065 |
3RT1065 |
2 x 3NA3354-6 |
3NE3336 |
3RT1076 |
3RT1076 |
3RT1065 |
3RT1065 |
3RW5245 |
2 x 3NA3365-6 |
3NE3336 |
3RT1075 |
3RT1075 |
2 x 3NA3365-6 |
3NE3336 |
3TF68 |
3TF68 |
3RT1075 |
3RT1075 |
3RW5246 |
2 x 3NA3365-6 |
3NE3336 |
3RT1075 |
3RT1075 |
2 x 3NA3365-6 |
3NE3336 |
3TF69 |
3TF69 |
3RT1075 |
3RT1075 |
3RW5247 |
2 x 3NA3365-6 |
3NE3340-8 |
3RT1076 |
3RT1276 |
2 x 3NA3365-6 |
3NE3340-8 |
3TF69 |
3TF69 |
3RT1076 |
3RT1276 |
3RW5248 |
2 x 3NA3365-6 |
3NE3340-8 |
3TF68 |
3TF68 |
2 x 3NA3365-6 |
3NE3340-8 |
-- |
-- |
3TF68 |
3TF68 |
Note:
The specified short-circuit breaking capacities Iq in kA are covered by combination tests. Smaller fuses than those specified can be used at any time as smaller ones trip more quickly in the event of a short circuit (unchanged short-circuit breaking capacity) and thus protect the soft starter in any case. The dimensioning of the short-circuit components must, however, be suitable for the connected three-phase motor and the line protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class full-range fuses for cable and line protection 3NA3 (F1), 3RV2/3VA motor starter protectors/circuit breakers can also be used, possibly with reduced short-circuit breaking capacity, see Table "Motor feeders according to IEC with 3RV2 / 3VA motor starter protectors (without semiconductor protection)". In these cases, optional line contactors can be dispensed with.
Article number |
|
3RW5213 |
3RW5216 |
3RW5224 |
3RW5226 |
3RW5243 |
|
---|---|---|---|---|---|---|---|
Installation/ mounting/ dimensions |
|
|
|
|
|
|
|
Width x Height x Depth |
mm |
170 × 275 × 152 |
185 × 306 × 203 |
210 × 393 × 203 |
|||
mounting type |
|
screw fixing |
|||||
mounting position |
|
+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface |
with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface |
with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
||
required spacing with side-by-side mounting |
|
|
|
|
|
|
|
|
mm |
100 |
|||||
|
mm |
5 |
|||||
|
mm |
75 |
|||||
installation altitude at height above sea level maximum 1) |
m |
5 000 |
|||||
protection class IP |
|
IP20 |
IP00 |
||||
Ambient conditions |
|
|
|
|
|
|
|
ambient temperature |
|
|
|
|
|
|
|
|
°C |
-25 ... +60 |
|||||
|
°C |
-40 ... +80 |
|||||
environmental category acc. to IEC 60721 |
|
|
|
|
|
|
|
|
|
3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
|||||
|
|
1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
|||||
|
|
2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
Article number |
|
3RW52..-..C0. |
3RW52..-..C1. |
|
---|---|---|---|---|
Control circuit/ Control |
|
|
|
|
control supply voltage |
|
|
|
|
|
V |
24/24 |
--/-- |
|
|
V |
-- |
110 ... 250 |
|
Relative negative tolerance/Relative positive tolerance at AC |
% |
-20/20 |
-15/10 |
|
Relative negative tolerance/Relative positive tolerance at DC |
% |
-20/20 |
--/-- |
|
control supply voltage frequency |
Hz |
50 ... 60 |
||
|
% |
-10/10 |
||
design of the overvoltage protection |
|
Varistor |
||
design of short-circuit protection / for control circuit 1) |
|
4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A) |
Article number |
|
3RW52..-..C.4 |
3RW52..-..C.5 |
|
---|---|---|---|---|
Power Electronics |
|
|
|
|
operating voltage rated value |
V |
200 ... 480 |
200 ... 600 |
|
|
% |
-15/10 |
||
operating voltage at inside-delta circuit rated value |
V |
200 ... 480 |
200 ... 600 |
|
|
% |
-15/10 |
||
Operating frequency |
Hz |
50 ... 60 |
||
|
% |
-10/10 |
||
minimum load [%] 1) |
% |
15 |
||
wire length between soft starter and motor maximum |
m |
800 |