Bộ lưu điện UPS DC 24V 5A 1.3AH Phoenix Contact QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254

Uninterruptible energy supply with IQ technology and integrated energy storage for DIN rail mounting, input 24 V DC, output: 24 V DC / 5 A, energy storage: lead AGM 1.2 Ah, incl. mounted UTA 107/30 universal DIN rail adapter

 

 

Product description

UPS modules with integrated energy storage are particularly space saving: UPS module and energy storage are combined in one housing. It's just a case of connecting a power supply upstream.

 

Technical data

Input data

DC operation
Input voltage 24 V DC
Input voltage range 18 V DC ... 30 V DC
Input voltage range DC 18 V DC ... 30 V DC
Voltage type of supply voltage DC
Buffer period 50 min. (1 A)
5 min. (5 A)
Current consumption 9.3 A (24 V DC)
9.7 mA
1.7 A
7 A
Fixed backup threshold ≤ 22.6 V DC
 

Output data

Efficiency > 97.1 % (Mains operation, with charged energy storage)
97.31 %
Nominal output voltage 24 V DC
Output voltage range 18 V DC ... 30 V DC
Nominal output current (IN) 5 A (0 °C ... 40 °C)
Output current limit > 7.5 A (Battery operation)
Bridging time 360 s
Derating 60 °C ... 70 °C (2.5%/K)
Output power 120 W
Power dissipation 2.5 W (Mains operation)
2.7 W (Mains operation)
1.9 W (Mains operation)
3.3 W (Battery operation)
3.3 W (Battery operation)
4.1 W (Battery operation)
Output fuse 1x 15 A
Connection in parallel 2
Connection in series No
Mains operation
Nominal output voltage 24 V DC
Output voltage range 18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 30 A (0 °C ... 40 °C)
Duration 12 ms (SFB technology)
Battery operation
Nominal output voltage 24 V DC
Output voltage range 19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 32.5 A (0 °C ... 40 °C)
Duration 15 ms (SFB technology)
Signal: Alarm
Output description Relay
Output voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA
Signal: Battery charge
Output description Relay
Output voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA
Signal: Battery mode
Output description Relay
Output voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA
Signal
Continuous load current ≤ 200 mA
 

Energy storage

Nominal voltage UN 24 V DC
End-of-charge voltage 24 V DC ... 29 V DC (temperature compensated)
Charging current 0.36 A
Nominal capacity 1.2 Ah
Buffer period 50 min. (1 A)
5 min. (5 A)
Latest startup date (battery only) 3 Months (0 °C ... 20 °C)
1 Months (30 °C ... 40 °C)
Latest startup (battery only) - range 1 Months ... 3 Months (20 °C ... 30 °C)
Battery technology VRLA-AGM
Memory medium VRLA-AGM Battery 1.2 Ah
Accumulator type 2x BB Battery BP1.2-12FR (from UPS V/C-level 05)
Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
IQ technology Yes
Temperature sensor yes
Network management Yes
 

Connection data

Input
Connection method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Output
Connection method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signal
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
 

Interfaces

Interface IFS (Interface system data port)
 

Signaling

Types of signaling LED
Relay contact
Interface/software
Signal output
Signalization designation Power In OK
Status display LED
Note on status display Static to
Static to
Signal output: Switching output
Signalization designation Alarm
Status display LED
Note on status display Static to
Color red
Note on status display Static to
Signal output: Switching output
Signalization designation Battery charge
Status display LED bar graph
Note on status display dynamic
Color red/green
Note on status display dynamic
Signal output: Switching output
Signalization designation Battery mode
Status display LED
Note on status display Static to
Color yellow
Note on status display Static to
 

Product properties

Product type DC UPS with integrated energy storage
Product family QUINT UPS ‒ UPS with integrated energy storage
Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
IQ technology Yes
MTBF (IEC 61709, SN 29500) > 806000 h (40 °C)
Insulation characteristics
Protection class III
Degree of pollution 2
Life expectancy (electrolytic capacitors)
Time 316800 h
 

Dimensions

Width 88 mm
Height 138 mm
Depth 125 mm
Installation dimensions
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
 

Mounting

Mounting type DIN rail mounting
Assembly instructions alignable: horizontal 5 mm, vertical 50 mm
Mounting position horizontal DIN rail NS 35, EN 60715
 

Material specifications

Housing material Metal
Type of housing Steel sheet, zinc-plated
Side element version Galvanized sheet steel, closed
Housing material Steel sheet, zinc-plated
 

Environmental and real-life conditions

Ambient conditions
Degree of protection IP20
Ambient temperature (storage/transport) -20 °C ... 40 °C
Ambient temperature (charge) 0 °C ... 40 °C
Ambient temperature (discharge) -20 °C ... 50 °C
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g t= 90 min.
 

Standards and regulations

Rail applications EN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
EN 61558-2-17
 

Approvals

UL approvals UL/C-UL Recognized UL 60950-1
UL Listed UL 508
 

EMC data

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m
Frequency range 2 GHz ... 3 GHz
Test field strength 3 V/m
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Emitted interference
Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
 

Commercial data

Item number 2320254
Packing unit 1 pc
Minimum order quantity 1 pc
Product key CMUQV3
Catalog page Page 344 (C-4-2019)
GTIN 4046356554145
Weight per piece (including packing) 2,540 g
Weight per piece (excluding packing) 2,137 g
Customs tariff number 85371091
Country of origin CN
 

Classifications

ECLASS

ECLASS-11.0 27040705
ECLASS-13.0 27040705
ECLASS-12.0 27040705
 

ETIM

ETIM 8.0 EC000382
 

UNSPSC

UNSPSC 21.0 39121000
 

Approvals

 

cUL Recognized

Approval ID: FILE E 211944
 

UL Recognized

Approval ID: FILE E 211944
 

EAC

Approval ID: EAC-Zulassung
 

EAC

Approval ID: RU S-DE.BL08.W.00764
 

UL Listed

Approval ID: FILE E 123528
 

cUL Listed

Approval ID: FILE E 123528
 

KC

Approval ID: R-R-PCK-2320254

 

cUL Listed

Approval ID: FILE E 199827
 

UL Listed

Approval ID: FILE E 199827
 

cULus Recognized

 

cULus Listed

 

cULus Listed

 

Environmental product compliance

 
REACh SVHC Lead 7439-92-1
 
China RoHS Environmentally Friendly Use Period = 3
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”


- Tài liệu kỹ thuật Phoenix Contact QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254 ở đây.

 

Compatible products

Data cable
IFS-USB-DATACABLE - 2320500
Data cable
IFS-RS232-DATACABLE - 2320490
Data cable
IFS-MINI-DIN-DATACABLE - 2320487
Data cable
IFS-OPEN-END-DATACABLE - 2320450
Mounting adapter
QUINT-PS-ADAPTERS7/1 - 2938196
Mounting adapter
UTA 107/30 - 2320089
Mounting adapter
UWA 182/52 - 2938235
Fuse
FUSE 15A/32V FKS ATO - 2908361
Memory block
IFS-CONFSTICK-L - 2901103
Uninterruptible power supply replacement battery
UPS-BAT-KIT/PB/2X12V/1.2AH - 1283114
SẢN PHẨM XEM NHIỀU
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại