Bộ lưu điện UPS DC 24V 5A 1.3AH Phoenix Contact QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254
Uninterruptible energy supply with IQ technology and integrated energy storage for DIN rail mounting, input 24 V DC, output: 24 V DC / 5 A, energy storage: lead AGM 1.2 Ah, incl. mounted UTA 107/30 universal DIN rail adapter
Product description
UPS modules with integrated energy storage are particularly space saving: UPS module and energy storage are combined in one housing. It's just a case of connecting a power supply upstream.
Technical data
Input data
DC operation |
Input voltage |
24 V DC |
Input voltage range |
18 V DC ... 30 V DC |
Input voltage range DC |
18 V DC ... 30 V DC |
Voltage type of supply voltage |
DC |
Buffer period |
50 min. (1 A) |
5 min. (5 A) |
Current consumption |
9.3 A (24 V DC) |
9.7 mA |
1.7 A |
7 A |
Fixed backup threshold |
≤ 22.6 V DC |
Output data
Efficiency |
> 97.1 % (Mains operation, with charged energy storage) |
97.31 % |
Nominal output voltage |
24 V DC |
Output voltage range |
18 V DC ... 30 V DC |
Nominal output current (IN) |
5 A (0 °C ... 40 °C) |
Output current limit |
> 7.5 A (Battery operation) |
Bridging time |
360 s |
Derating |
60 °C ... 70 °C (2.5%/K) |
Output power |
120 W |
Power dissipation |
2.5 W (Mains operation) |
2.7 W (Mains operation) |
1.9 W (Mains operation) |
3.3 W (Battery operation) |
3.3 W (Battery operation) |
4.1 W (Battery operation) |
Output fuse |
1x 15 A |
Connection in parallel |
2 |
Connection in series |
No |
Mains operation |
Nominal output voltage |
24 V DC |
Output voltage range |
18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC) |
Nominal output current (IN) |
5 A (0 °C ... 40 °C) |
POWER BOOST (IBoost) |
7.5 A (0 °C ... 40 °C) |
Selective Fuse Breaking (ISFB) |
30 A (0 °C ... 40 °C) |
Duration |
12 ms (SFB technology) |
Battery operation |
Nominal output voltage |
24 V DC |
Output voltage range |
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC) |
Nominal output current (IN) |
5 A (0 °C ... 40 °C) |
POWER BOOST (IBoost) |
7.5 A (0 °C ... 40 °C) |
Selective Fuse Breaking (ISFB) |
32.5 A (0 °C ... 40 °C) |
Duration |
15 ms (SFB technology) |
Signal: Alarm |
Output description |
Relay |
Output voltage |
≤ 30 V AC/DC |
Continuous load current |
≤ 100 mA |
Signal: Battery charge |
Output description |
Relay |
Output voltage |
≤ 30 V AC/DC |
Continuous load current |
≤ 100 mA |
Signal: Battery mode |
Output description |
Relay |
Output voltage |
≤ 30 V AC/DC |
Continuous load current |
≤ 100 mA |
Signal |
Continuous load current |
≤ 200 mA |
Energy storage
Nominal voltage UN |
24 V DC |
End-of-charge voltage |
24 V DC ... 29 V DC (temperature compensated) |
Charging current |
0.36 A |
Nominal capacity |
1.2 Ah |
Buffer period |
50 min. (1 A) |
5 min. (5 A) |
Latest startup date (battery only) |
3 Months (0 °C ... 20 °C) |
1 Months (30 °C ... 40 °C) |
Latest startup (battery only) - range |
1 Months ... 3 Months (20 °C ... 30 °C) |
Battery technology |
VRLA-AGM |
Memory medium |
VRLA-AGM Battery 1.2 Ah |
Accumulator type |
2x BB Battery BP1.2-12FR (from UPS V/C-level 05) |
Disposal |
Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations. |
IQ technology |
Yes |
Temperature sensor |
yes |
Network management |
Yes |
Connection data
Input |
Connection method |
Screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
20 |
Conductor cross section AWG max. |
12 |
Stripping length |
7 mm |
Screw thread |
M4 |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Output |
Connection method |
Screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
20 |
Conductor cross section AWG max. |
12 |
Stripping length |
7 mm |
Screw thread |
M4 |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Signal |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
12 |
Screw thread |
M4 |
Tightening torque, min |
0.5 Nm |
Tightening torque max |
0.6 Nm |
Interfaces
Interface |
IFS (Interface system data port) |
Signaling
Types of signaling |
LED |
Relay contact |
Interface/software |
Signal output |
Signalization designation |
Power In OK |
Status display |
LED |
Note on status display |
Static to |
Static to |
Signal output: Switching output |
Signalization designation |
Alarm |
Status display |
LED |
Note on status display |
Static to |
Color |
red |
Note on status display |
Static to |
Signal output: Switching output |
Signalization designation |
Battery charge |
Status display |
LED bar graph |
Note on status display |
dynamic |
Color |
red/green |
Note on status display |
dynamic |
Signal output: Switching output |
Signalization designation |
Battery mode |
Status display |
LED |
Note on status display |
Static to |
Color |
yellow |
Note on status display |
Static to |
Product properties
Product type |
DC UPS with integrated energy storage |
Product family |
QUINT UPS ‒ UPS with integrated energy storage |
Disposal |
Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations. |
IQ technology |
Yes |
MTBF (IEC 61709, SN 29500) |
> 806000 h (40 °C) |
Insulation characteristics |
Protection class |
III |
Degree of pollution |
2 |
Life expectancy (electrolytic capacitors) |
Time |
316800 h |
Dimensions
Width |
88 mm |
Height |
138 mm |
Depth |
125 mm |
Installation dimensions |
Installation distance right/left |
5 mm / 5 mm |
Installation distance top/bottom |
50 mm / 50 mm |
Mounting
Mounting type |
DIN rail mounting |
Assembly instructions |
alignable: horizontal 5 mm, vertical 50 mm |
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
Material specifications
Housing material |
Metal |
Type of housing |
Steel sheet, zinc-plated |
Side element version |
Galvanized sheet steel, closed |
Housing material |
Steel sheet, zinc-plated |
Environmental and real-life conditions
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (storage/transport) |
-20 °C ... 40 °C |
Ambient temperature (charge) |
0 °C ... 40 °C |
Ambient temperature (discharge) |
-20 °C ... 50 °C |
Climatic class |
3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) |
≤ 95 % (25 °C, non-condensing) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g tv = 90 min. |
Standards and regulations
Rail applications |
EN 50121-4 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety |
EN 60950-1/VDE 0805 (SELV) |
EN 61558-2-17 |
Approvals
UL approvals |
UL/C-UL Recognized UL 60950-1 |
UL Listed UL 508 |
EMC data
Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission |
EN 61000-6-3 |
EN 61000-6-4 |
EMC requirements for noise immunity |
EN 61000-6-1 |
EN 61000-6-2 |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge |
Standards/regulations |
EN 61000-4-2 |
Electrostatic discharge |
Contact discharge |
8 kV (Test Level 4) |
Discharge in air |
15 kV (Test Level 4) |
Comments |
Criterion A |
Electromagnetic HF field |
Standards/regulations |
EN 61000-4-3 |
Electromagnetic HF field |
Frequency range |
80 MHz ... 1 GHz |
Test field strength |
20 V/m |
Frequency range |
1 GHz ... 2 GHz |
Test field strength |
10 V/m |
Frequency range |
2 GHz ... 3 GHz |
Test field strength |
3 V/m |
Comments |
Criterion A |
Fast transients (burst) |
Standards/regulations |
EN 61000-4-4 |
Fast transients (burst) |
Input |
2 kV (Test Level 3 - asymmetrical) |
Output |
2 kV (Test Level 3 - asymmetrical) |
Signal |
2 kV (Test Level 4 - asymmetrical) |
Comments |
Criterion A |
Surge voltage load (surge) |
Standards/regulations |
EN 61000-4-5 |
Input |
1 kV (Test Level 2 - symmetrical) |
2 kV (Test Level 3 - asymmetrical) |
Output |
1 kV (Test Level 2 - symmetrical) |
2 kV (Test Level 3 - asymmetrical) |
Signal |
1 kV (Test Level 2 - asymmetrical) |
Comments |
Criterion A |
Conducted interference |
Standards/regulations |
EN 61000-4-6 |
Conducted interference |
I/O/S |
asymmetrical |
Frequency range |
0.15 MHz ... 80 MHz |
Comments |
Criterion A |
Voltage |
10 V (Test Level 3) |
Emitted interference |
Standards/regulations |
EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria |
Criterion A |
Normal operating behavior within the specified limits. |
Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Commercial data
Item number |
2320254 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product key |
CMUQV3 |
Catalog page |
Page 344 (C-4-2019) |
GTIN |
4046356554145 |
Weight per piece (including packing) |
2,540 g |
Weight per piece (excluding packing) |
2,137 g |
Customs tariff number |
85371091 |
Country of origin |
CN |
Classifications
ECLASS
ECLASS-11.0 |
27040705 |
ECLASS-13.0 |
27040705 |
ECLASS-12.0 |
27040705 |
ETIM
UNSPSC
Approvals
cUL Recognized
Approval ID: FILE E 211944
UL Recognized
Approval ID: FILE E 211944
EAC
Approval ID: EAC-Zulassung
EAC
Approval ID: RU S-DE.BL08.W.00764
UL Listed
Approval ID: FILE E 123528
cUL Listed
Approval ID: FILE E 123528
KC
Approval ID: R-R-PCK-2320254
cUL Listed
Approval ID: FILE E 199827
UL Listed
Approval ID: FILE E 199827
cULus Recognized
cULus Listed
cULus Listed
Environmental product compliance
|
REACh SVHC |
Lead 7439-92-1 |
|
China RoHS |
Environmentally Friendly Use Period = 3 |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
- Tài liệu kỹ thuật Phoenix Contact QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254
ở đây.
Compatible products
Data cable
IFS-USB-DATACABLE - 2320500
Data cable
IFS-RS232-DATACABLE - 2320490
Data cable
IFS-MINI-DIN-DATACABLE - 2320487
Data cable
IFS-OPEN-END-DATACABLE - 2320450
Mounting adapter
QUINT-PS-ADAPTERS7/1 - 2938196
Mounting adapter
UTA 107/30 - 2320089
Mounting adapter
UWA 182/52 - 2938235
Fuse
FUSE 15A/32V FKS ATO - 2908361
Memory block
IFS-CONFSTICK-L - 2901103
Uninterruptible power supply replacement battery
UPS-BAT-KIT/PB/2X12V/1.2AH - 1283114