Width | 100 mm |
Height | 130 mm |
Depth | 125 mm |
Degree of protection | IP20 |
Ambient temperature (operation) | 0 °C ... 50 °C |
Ambient temperature (storage/transport) | 0 °C ... 40 °C |
Max. permissible relative humidity (operation) | 95 % (at 25 °C, non-condensing) |
Nominal input voltage | 24 V DC |
Input voltage range | 22.5 V DC ... 30 V DC |
Current consumption | approx. 0.1 A |
0.5 A (charging process) | |
10.5 A (max.) | |
Current consumption (maximum) | 10.5 A (max.) |
Current consumption (idle) | approx. 0.1 A |
Current consumption (charging process) | 0.5 A (charging process) |
Buffer period | 1.5 min. (10 A) |
20 min. (2 A) | |
Input fuse | 15 A (slow-blow, internal) |
Nominal output voltage | 24 V DC (Normal operation: Uin- 0.5 V DC, buffer mode: 27.9 to 19.2 V DC) |
Nominal output current (IN) | 10 A |
Connection in parallel | No |
Connection in series | yes |
Output power | 240 W |
Disposal | Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations. They can also be returned to Phoenix Contact or the manufacturer. |
Net weight | 1.8 kg |
Memory medium | Internal, battery 1.3 Ah |
Operating voltage display | Green LED |
Efficiency | > 91 % |
Insulation voltage input/output | 2 kV (routine test) |
4 kV (type test) | |
Protection class | II (in closed control cabinet) |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 500000 h |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Connection method | Pluggable screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Output description | Power OK |
Status display | LED "Power OK" green |
Note on status display | Power OK: LED permanently lit |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Screw thread | M3 |
Output name | floating |
Output description | Alarm |
Maximum switching voltage | ≤ 30 V AC/DC |
Continuous load current | ≤ 1 A |
Status display | LED red |
Note on status display | Alarm: LED permanently lit |
Output name | floating |
Output description | Battery Charge |
Maximum switching voltage | ≤ 30 V AC/DC |
Continuous load current | ≤ 1 A |
Status display | LED yellow, flashing |
Note on status display | Battery charge: LED flashing |
Output name | floating |
Output description | Battery Mode |
Type of signaling | LED, relay contact |
Maximum switching voltage | ≤ 30 V AC/DC |
Continuous load current | ≤ 1 A |
Status display | Yellow LED |
Note on status display | Battery mode: LED permanently lit |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 (EN 55022) |
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CUL |
Low Voltage Directive | Conformance with LV directive 2006/95/EC |
Standard - Safety of transformers | EN 61558-2-17 |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
EN 61558-2-17 | |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Shipbuilding approval | DNV GL (EMC A), ABS |
UL approvals | UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 | |
UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D |
China RoHS | Environmentally Friendly Use Period = 3 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 4.0 | 27040603 |
eCl@ss 4.1 | 27040603 |
eCl@ss 5.0 | 27040603 |
eCl@ss 5.1 | 27040603 |
eCl@ss 6.0 | 27040603 |
eCl@ss 7.0 | 27040603 |
eCl@ss 8.0 | 27040603 |
eCl@ss 9.0 | 27040705 |
ETIM 2.0 | EC000382 |
ETIM 3.0 | EC000382 |
ETIM 4.0 | EC000382 |
ETIM 5.0 | EC000382 |
ETIM 6.0 | EC000382 |
UNSPSC 6.01 | 30211510 |
UNSPSC 7.0901 | 39121011 |
UNSPSC 11 | 39121011 |
UNSPSC 12.01 | 39121011 |
UNSPSC 13.2 | 39121011 |