Cảm biến lưu lượng 21lpmin DN10 16bar 4-20mA G1/2 IP67 Sick FFUC10-1G1IO | 6049016
Features
- Measurement principle: Ultrasonic sensor
- Medium: Fluids
- Nominal width measuring tube: DN 10
- Process temperature: 0 °C ... +80 °C
- Process pressure: ≤ 16 bar
Technical drawings
Dimensional drawing DN 10, G ½
Dimensions in mm (inch)
Connection type
① L+: Supply voltage
② Q1: Digital output PNP/NPN
③ M: Ground
④ C: Communication
⑤ QA: Analog current output
Performance
- Minimim flow: ≥ 0.3 l/min 1)
- Maximum flow: 0 l/min ... 21 l/min
- Inlet zone: 10 cm
- Output zone: 0 cm
- Conductivity: No limitation
- Measurement accuracy: ± 1 % of measured value +/- 0.15% of measuring range limit value (with calibration log) 2)
- Repeatability: ≤ 0.5 %
- Resolution: 0.003 l/min
- Calibration certificate: ✔
1) At constant flow rate.
2) Reference condition: Water, zero gas, measuring tube completely full, no cavitation, temperature of medium 20 °C, ambient temperature 20 °C ... 25 °C, compliance with inlet and outlet zones, warm-up time for electronics: 30 min.
Electronics
- Supply voltage: 18 V DC ... 30 V DC 1)
- Residual ripple: ≤ 5 Vpp 2)
- Power consumption: ≤ 180 mA 3)
- Initialization time: ≤ 5 s
- Protection class: III
- Connection type: Round connector M12 x 1, 5-pin
- Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) 1)
- Output current: < 100 mA 4)
- Output load: < 500 Ohm
- Lower signal level: 3.8 mA ... 4 mA
- Upper signal level: 20 mA ... 20.5 mA
- Impuls/frequency output: 0 kHz ... 10 kHz
- Puls width: ≤ 1 s
- Inductive load: 1 H
- Capacitive load: 100 nF
- Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s 5)
1) All connections are polarity protected. All outputs are overload and short-circuit protected.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) There are 100 mA for each output PNP and NPN available.
5) Analog output and display.
Mechanics
- Process connection: G ½
- Wetted parts: PPSU
- EPDM
- Housing material: PPSU
- Enclosure rating: IP67
- Weight: 340 g
Ambient data
- Ambient operating temperature: 0 °C ... +60 °C
- Ambient temperature, storage: –20 °C ... +70 °C
Classifications
- ECLASS 5.0: 27200412
- ECLASS 5.1.4: 27200412
- ECLASS 6.0: 27200412
- ECLASS 6.2: 27200412
- ECLASS 7.0: 27200412
- ECLASS 8.0: 27200412
- ECLASS 8.1: 27200412
- ECLASS 9.0: 27200412
- ECLASS 10.0: 27200412
- ECLASS 11.0: 27200412
- ECLASS 12.0: 27200412
- ETIM 5.0: EC002580
- ETIM 6.0: EC002580
- ETIM 7.0: EC002580
- ETIM 8.0: EC002580
- UNSPSC 16.0901: 41112501
Customs data
- Unit weight: 0.632 Kilograms
- Net unit weight: 0.632 Kilograms
- Unit volume: 4900 Cubic Centimetres (cm³)
- Measurements: 17.500*10.000*28.000
- Country of origin: Germany
- Tài liệu kỹ thuật Sick FFUC10-1G1IO | 6049016
ở đây.