Cảm biến rung 0-50g 0-45mm/s 2-10000Hz PNP/NPN NO/NC IP-67-68-69K IFM VVB020
- Condition-based maintenance thanks to monitoring of unbalance, rolling element bearing or gear state
- Large operating temperature range and high protection rating for the requirements of harsh industrial environments
- Reliable and permanent monitoring of characteristic values incl. raw data acquisition
- Integration in Industrial Ethernet systems without control cabinet and complex wiring
- Asynchronous transmission of raw data (BLOB) and integrated operating hours counter
Product characteristics
Frequency range [Hz] |
2...10000 |
Measuring principle |
capacitive |
v-RMS
Measuring range of vibration [mm/s] |
0...45 |
a-Peak / a-RMS
Measuring range of vibration |
|
Application
Application |
medium-sized machines, power < 300 kW, rotational speed > 600 rpm |
Electrical data
Operating voltage [V] |
18...30 DC |
Current consumption [mA] |
< 50 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Sensor type |
microelectromechanical system (MEMS) |
Inputs / outputs
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs
Output signal |
switching signal; IO-Link |
Electrical design |
PNP/NPN; (configurable) |
Number of digital outputs |
2 |
Output function |
normally open / normally closed |
Max. voltage drop switching output DC [V] |
2 |
Max. current load per output [mA] |
100 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range
Note on setpoint SP |
|
Frequency range [Hz] |
2...10000 |
Measuring principle |
capacitive |
Number of measurement axes |
1 |
v-RMS
Measuring range of vibration [mm/s] |
0...45 |
Set point SP [mm/s] |
0.2...45 |
Reset point rP [mm/s] |
0...44.8 |
In steps of [mm/s] |
0.2 |
a-Peak / a-RMS
Measuring range of vibration |
|
Set point SP |
0.2...50 g |
2...490.3 m/s² |
|
Reset point rP |
0...49.8 g |
0...488.3 m/s² |
|
In steps of |
|
Crest
Measuring range of vibration |
1...50 |
Set point SP |
2...50 |
Reset point rP |
1...49 |
In steps of |
1 |
Temperature measurement
Measuring range [°C] |
-30...80 |
Resolution [°C] |
0.1 |
Set point SP [°C] |
-28...80 |
Reset point rP [°C] |
-30...78 |
In steps of [°C] |
2 |
Accuracy / deviations
Accuracy |
≤ 4 kHz +/-10 %; ≥ 4...10 kHz: < 3 dB |
Accuracy [K] |
± 2,5 K + (0,2 x (Umgebungstemperatur - Oberflächentemperatur)) |
Linearity deviation |
2 % |
Software / programming
Parameter setting options |
Software |
Diagnostic functions |
self-test |
Interfaces
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud); COM3 (230,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9: 2013-07 |
Profiles |
Blob (0x0030); Measuring sensor (0x800A); Common Profile (0x4000) |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
10 |
Process data binary |
2 |
Min. process cycle time [ms] |
3.6 |
IO-Link functions (acyclical) |
filter for v-RMS, a-RMS, a-Peak; Hysteresis; window; switch points; switching logic |
Supported DeviceIDs |
Type of operation |
DeviceID |
Status A (COM2) |
1257 |
Status B (COM2 / COM3) |
1369 |
|
Note |
For further information please see the IODD PDF file under "Downloads" |
|
Operating conditions
Ambient temperature [°C] |
-30...60 |
Storage temperature [°C] |
-30...80 |
Protection |
IP 67; IP 68; IP 69K |
Tests / approvals
EMC |
2014/30/EU |
|
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
|
Shock resistance |
DIN EN 60068-2-27 |
50 g 11 ms |
|
500 g 1 ms |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g / 10...3000 Hz |
|
MTTF [years] |
299 |
UL approval |
Ta |
-30...60 °C |
UL Approval no. |
L002 |
|
Mechanical data
Weight [g] |
116.5 |
Type of mounting |
set screw |
Materials |
housing: stainless steel (1.4404 / 316L) |
Tightening torque [Nm] |
8 |
Accessories
Items supplied |
set screw: 1 x 1/4" 28 UNF / M8 |
set screw: 1 x 1/4"28 UNF x 5/8" DIN916 |
|
Remarks
Notes |
the hardware version BC has a temporarily changed ambient temperature range |
Pack quantity |
1 pcs. |
Electrical connection
|
Connector: 1 x M12; coding: A; Maximum cable length: 20 m |
(
Đơn hàng: Vibration sensor
VVB020, IO-Link master
AL1306, Cable
EVT068, Wirable plug
E12289, Connection cable
EVT05, Mounting adapter
E30468)
- Tài liệu kỹ thuật IFM VVB020
ở đây.
Tham khảo thêm các model khác cùng loại:
VVB001
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB010
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB011
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB020
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB021
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VKV021
Measuring range of vibration
0...25 mm/s
Frequency range
10...1000 Hz
Output function
normally closed; analogue
Approval
CE
cULus
UKCA
Protection
IP 67
VTV122
Measuring range of vibration
0...25 mm/s
Frequency range
10...1000 Hz
Output function
analogue
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
ZZ0809
Measuring range of vibration
–
Frequency range
–
Output function
–
Approval
–
Protection
–
VKV022
Measuring range of vibration
0...50 mm/s
Frequency range
10...1000 Hz
Output function
normally closed; analogue
Approval
CE
cULus
UKCA
Protection
IP 67
VNB001
Measuring range of vibration
0...500 mm/s
Frequency range
2...1000 Hz
Output function
analogue
Approval
CE
cULus
UKCA
Protection
IP 67
VTV121
Measuring range of vibration
0...50 mm/s
Frequency range
10...1000 Hz
Output function
analogue
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VTV12A
Measuring range of vibration
0...25 mm/s
Frequency range
10...1000 Hz
Output function
analogue
Approval
CE
UKCA
ATEX II 3D
ATEX II 3G
Protection
IP 67
ZB0929
Measuring range of vibration
–
Frequency range
–
Output function
–
Approval
CE
FCC
UKCA
Protection
IP 20
VWV001
Measuring range of vibration
0...25 mm/s
-16...16 g
Frequency range
10...1000 Hz
Output function
–
Approval
CE
FCC
UKCA
Protection
IP 68
VWV002
Measuring range of vibration
0...25 mm/s
-16...16 g
Frequency range
10...1000 Hz
Output function
–
Approval
CE
FCC
UKCA
Protection
IP 68
VSE002
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
TCP/IP
Operating voltage DC
24 V
VSE003
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
TCP/IP
Operating voltage DC
24 V
VSE100
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
TCP/IP
Operating voltage DC
24 V
VSE150
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
PROFINET IO
Operating voltage DC
24 V
VSE151
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
EtherNet/IP
Operating voltage DC
24 V
VSE153
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
Modbus TCP
Operating voltage DC
24 V
VSE903
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
TCP/IP
Operating voltage DC
24 V
VSE950
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0...12000 Hz
Communication interface
Ethernet
Protocol
PROFINET
Operating voltage DC
24 V
VSE951
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0...12000 Hz
Communication interface
Ethernet
Protocol
EtherNet/IP
Operating voltage DC
24 V
VSE953
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0...12000 Hz
Communication interface
Ethernet
Protocol
Modbus TCP
Operating voltage DC
24 V
VSE101
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
TCP/IP
Operating voltage DC
24 V
VSE152
Product designation
Diagnostic electronics for vibration sensors
Frequency range
0.1...12000 Hz
Communication interface
Ethernet
Protocol
EtherCAT
Operating voltage DC
24 V
VSM101
Measuring range of vibration
-40...40 g
Frequency range
0...4500 Hz
Ambient temperature
-30...85 °C
Protection
IP 67
IP 68
IP 69K
Approval
CE
UKCA
cULus
VSM102
Measuring range of vibration
-40...40 g
Frequency range
1...4500 Hz
Ambient temperature
-30...85 °C
Protection
IP 67
Approval
CE
UKCA
cULus
VSM103
Measuring range of vibration
-40...40 g
Frequency range
0...4500 Hz
Ambient temperature
-30...85 °C
Protection
IP 67
IP 68
IP 69K
Approval
CE
UKCA
cULus
VSM104
Measuring range of vibration
-40...40 g
Frequency range
0...4500 Hz
Ambient temperature
-30...85 °C
Protection
IP 67
IP 68
IP 69K
Approval
CE
UKCA
cULus
VSA001
Measuring range of vibration
-25...25 g
Frequency range
1...6000 Hz
Ambient temperature
-30...125 °C
Protection
IP 67
IP 68
IP 69K
Approval
CE
cULus
UKCA
VSA007
Measuring range of vibration
-25...25 g
Frequency range
1...6000 Hz
Ambient temperature
-30...125 °C
Protection
IP 67
IP 68
IP 69K
Approval
CE
UKCA
cULus
VSA005
Measuring range of vibration
-25...25 g
Frequency range
1...10000 Hz
Ambient temperature
-20...80 °C
Protection
IP 67
Approval
CE
cULus
UKCA
VSA205
Measuring range of vibration
-150...150 g
Frequency range
1...10000 Hz
Ambient temperature
-20...80 °C
Protection
IP 67
Approval
CE
cULus
UKCA
VSA004
Measuring range of vibration
-25...25 g
Frequency range
1...10000 Hz
Ambient temperature
-20...80 °C
Protection
IP 67
Approval
CE
cULus
UKCA
VSA204
Measuring range of vibration
-150...150 g
Frequency range
1...10000 Hz
Ambient temperature
-20...80 °C
Protection
IP 67
Approval
CE
cULus
UKCA
VSP001
Measuring range of vibration
-50...50 g
Frequency range
2...10000 Hz
Ambient temperature
-55...125 °C
Protection
IP 67
Approval
CE
UKCA
VSP01A
Measuring range of vibration
-50...50 g
Frequency range
2...10000 Hz
Ambient temperature
-55...90 °C
Protection
IP 68
Approval
CE
IECEx
ATEX II 1D
ATEX II 1G
VSP003
Measuring range of vibration
-50...50 g
Frequency range
1.5...16000 Hz
Ambient temperature
-55...130 °C
Protection
IP 67
Approval
CE
UKCA
VSP004
Measuring range of vibration
-50...50 g
Frequency range
1.5...12000 Hz
Ambient temperature
-50...150 °C
Protection
IP 68
Approval
CE
UKCA
VSA201
Measuring range of vibration
-250...250 g
Frequency range
1...6000 Hz
Ambient temperature
-30...125 °C
Protection
IP 67
IP 68
IP 69K
Approval
CE
cULus
UKCA
VSP02A
Measuring range of vibration
-50...50 g
Frequency range
2...10000 Hz
Ambient temperature
-55...90 °C
Protection
IP 68
Approval
CE
IECEx
ATEX I M1
VSA006
Measuring range of vibration
-25...25 g
Frequency range
1...10000 Hz
Ambient temperature
-30...85 °C
Protection
IP 67
Approval
CE
cULus
UKCA
VSA002
Measuring range of vibration
-25...25 g
Frequency range
1...10000 Hz
Ambient temperature
-30...85 °C
Protection
IP 67
Approval
CE
cULus
UKCA
VSA008
Measuring range of vibration
-25...25 g
Frequency range
1...10000 Hz
Ambient temperature
-30...80 °C
Protection
IP 67
Approval
CE
cULus
UKCA
E30115
Product designation
Conical washer
E30132
Product designation
screw-in adapter
EC2080
Product designation
Connection cable
E30136
Product designation
USB adapter cable
E30137
Product designation
screw-in adapter
E30112
Product designation
Connection cable
E30094
Product designation
Protective cover
E12405
Product designation
Y connection cable
ZB0929
Product designation
gateway for wireless vibration sensors
E30448
Product designation
magnetic mount
E30449
Product designation
magnetic mount
E30491
Product designation
magnetic mount
ZJF056
Product designation
current transducer
ZJF057
Product designation
current transducer
ZJF058
Product designation
current transducer