Cảm biến rung 0-25 RMS mm/s 10-1000Hz PNP NC Analog 2IO IFM VKV021
Vibration monitor; PNP; normally closed; analogue; Total number of inputs and outputs 2; Number of measurement axes 1; Measuring range of vibration 0...25; (RMS) mm/s; Frequency range 10...1000 Hz; Ambient temperature -25...80 °C; IP 67; Connector
Vibration monitor with intuitive switch point setting
VKV021
VIBRATION MONITOR
- Reliable permanent monitoring of the overall vibration to DIN ISO 10816
- Switching output with adjustable switch point and response delay
- Simple switch point setting by means of two setting rings allowing optimum reading
- With analogue current output for vibration velocity
- Clearly visible LEDs for indicating switching status and operation
Product characteristics
Measuring range of vibration [mm/s] |
0...25; (RMS) |
Frequency range [Hz] |
10...1000 |
Application
Application |
vibration monitor to DIN ISO 10816 |
Electrical data
Operating voltage [V] |
18...32 DC |
Current consumption [mA] |
< 50 |
Protection class |
III |
Sensor type |
microelectromechanical system (MEMS) |
Inputs / outputs
Total number of inputs and outputs |
2 |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
Output signal |
switching signal; analogue signal |
Electrical design |
PNP |
Number of digital outputs |
1 |
Output function |
normally closed |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
500 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20 |
Max. load [Ω] |
500 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range
Measuring range of vibration [mm/s] |
0...25; (RMS) |
Frequency range [Hz] |
10...1000 |
Number of measurement axes |
1 |
Accuracy / deviations
Measuring error [% of the final value] |
< ± 3 |
Linearity deviation |
0,25 % |
Response times
Software / programming
Adjustment of the switch point |
setting ring |
Operating conditions
Ambient temperature [°C] |
-25...80 |
Note on ambient temperature |
|
Storage temperature [°C] |
-25...80 |
Protection |
IP 67 |
Tests / approvals
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-6 HF conducted |
10 V |
|
Shock resistance |
|
MTTF [years] |
510 |
Mechanical data
Weight [g] |
113.5 |
Type of mounting |
M8 x 1,25 |
Materials |
PBT; PC; FKM; stainless steel (316L/1.4404) |
Tightening torque [Nm] |
15 |
Displays / operating elements
Display |
operation |
LED, green |
switching status |
LED, yellow |
|
With scale |
yes |
Operating elements |
setting ring |
setting ring |
|
Remarks
Electrical connection
Connection |
Connector: 1 x M12; coding: A |
- Tài liệu kỹ thuật IFM VKV021
ở đây.
Tham khảo thêm các model khác cùng loại:
VVB001
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB010
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB011
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB020
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VVB021
Measuring range of vibration
0...45 mm/s
0...50 g
Frequency range
2...10000 Hz
Output function
normally open / normally closed; (parameterisable)
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VKV021
Measuring range of vibration
0...25 mm/s
Frequency range
10...1000 Hz
Output function
normally closed; analogue
Approval
CE
cULus
UKCA
Protection
IP 67
VTV122
Measuring range of vibration
0...25 mm/s
Frequency range
10...1000 Hz
Output function
analogue
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
ZZ0809
Measuring range of vibration
–
Frequency range
–
Output function
–
Approval
–
Protection
–
VKV022
Measuring range of vibration
0...50 mm/s
Frequency range
10...1000 Hz
Output function
normally closed; analogue
Approval
CE
cULus
UKCA
Protection
IP 67
VNB001
Measuring range of vibration
0...500 mm/s
Frequency range
2...1000 Hz
Output function
analogue
Approval
CE
cULus
UKCA
Protection
IP 67
VTV121
Measuring range of vibration
0...50 mm/s
Frequency range
10...1000 Hz
Output function
analogue
Approval
CE
cULus
UKCA
Protection
IP 67
IP 68
IP 69K
VTV12A
Measuring range of vibration
0...25 mm/s
Frequency range
10...1000 Hz
Output function
analogue
Approval
CE
UKCA
ATEX II 3D
ATEX II 3G
Protection
IP 67
ZB0929
Measuring range of vibration
–
Frequency range
–
Output function
–
Approval
CE
FCC
UKCA
Protection
IP 20
VWV001
Measuring range of vibration
0...25 mm/s
-16...16 g
Frequency range
10...1000 Hz
Output function
–
Approval
CE
FCC
UKCA
Protection
IP 68
VWV002
Measuring range of vibration
0...25 mm/s
-16...16 g
Frequency range
10...1000 Hz
Output function
–
Approval
CE
FCC
UKCA
Protection
IP 68