Note | For terminal marking, please use marking material with 8.2 mm pitch. |
---|---|
For lever marking, please use marking material with 6.2 mm pitch. | |
Number of levels | 1 |
Number of connections | 2 |
Nominal cross section | 4 mm² |
Color | black |
Insulating material | PA |
Flammability rating according to UL 94 | V2 |
Maximum power dissipation for nominal condition | 1.02 W |
Fuse | G / 5 x 20 |
Fuse type | Glass / ceramics / ... |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Connection in acc. with standard | IEC 60947-7-3 |
Maximum load current | 6.3 A |
Nominal current IN | 6.3 A |
Nominal voltage UN | 800 V (As a fuse terminal block) |
Connection in acc. with standard | IEC 60947-7-3 |
Open side panel | No |
Shock protection test specification | DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection | guaranteed |
Finger protection | guaranteed |
Oscillation, broadband noise test result | Test passed |
Test specification, oscillation, broadband noise | DIN EN 50155 (VDE 0115-200):2008-03 |
Test spectrum | Service life test category 1, class B, body mounted |
Test frequency | f1 = 5 Hz to f2 = 150 Hz |
ASD level | 1.857 (m/s2)2/Hz |
Acceleration | 0,8 g |
Test duration per axis | 5 h |
Test directions | X-, Y- and Z-axis |
Shock test result | Test passed |
Test specification, shock test | DIN EN 50155 (VDE 0115-200):2008-03 |
Shock form | Half-sine |
Acceleration | 5g |
Shock duration | 30 ms |
Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) |
Relative insulation material temperature index (Elec., UL 746 B) | 125 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Width | 8.2 mm |
---|---|
Length | 72.5 mm |
Height NS 35/7,5 | 56.5 mm |
Height NS 35/15 | 64 mm |
Height NS 32 | 61.5 mm |
Ambient temperature (operation) | -60 °C ... 85 °C |
---|---|
Ambient temperature (storage/transport) | -25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C) |
Permissible humidity (storage/transport) | 30 % ... 70 % |
Ambient temperature (assembly) | -5 °C ... 70 °C |
Ambient temperature (actuation) | -5 °C ... 70 °C |
Conductor cross section solid min. | 0.2 mm² |
---|---|
Conductor cross section solid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 4 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 4 mm² |
Cross section with insertion bridge, solid max. | 4 mm² |
Cross section with insertion bridge, stranded max. | 4 mm² |
2 conductors with same cross section, solid min. | 0.2 mm² |
2 conductors with same cross section, solid max. | 1.5 mm² |
2 conductors with same cross section, stranded min. | 0.2 mm² |
2 conductors with same cross section, stranded max. | 1.5 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum | 0.25 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum | 1.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum | 0.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum | 1.5 mm² |
Cross section with insertion bridge, solid max. | 4 mm² |
Cross section with insertion bridge, stranded max. | 4 mm² |
Connection method | Screw connection |
Stripping length | 8 mm |
Internal cylindrical gage | A4 |
Screw thread | M3 |
Tightening torque, min | 0.6 Nm |
Tightening torque max | 0.8 Nm |
Connection in acc. with standard | CSA |
---|---|
IEC 60947-7-3 | |
Flammability rating according to UL 94 | V2 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 27141116 |
---|---|
eCl@ss 4.0 | 27141100 |
eCl@ss 4.1 | 27141100 |
eCl@ss 5.0 | 27141100 |
eCl@ss 5.1 | 27141100 |
eCl@ss 6.0 | 27141100 |
eCl@ss 7.0 | 27141116 |
eCl@ss 8.0 | 27141116 |
eCl@ss 9.0 | 27141116 |
ETIM 2.0 | EC000897 |
---|---|
ETIM 3.0 | EC000899 |
ETIM 4.0 | EC000899 |
ETIM 5.0 | EC000899 |
ETIM 6.0 | EC000899 |
ETIM 7.0 | EC000899 |
UNSPSC 6.01 | 30211811 |
---|---|
UNSPSC 7.0901 | 39121410 |
UNSPSC 11 | 39121410 |
UNSPSC 12.01 | 39121410 |
UNSPSC 13.2 | 39121410 |
UNSPSC 18.0 | 39121410 |
UNSPSC 19.0 | 39121410 |
UNSPSC 20.0 | 39121410 |
UNSPSC 21.0 | 39121410 |