Number of levels |
1 |
Number of connections |
2 |
Nominal cross section |
4 mm² |
Color |
black |
Insulating material |
PA |
Flammability rating according to UL 94 |
V0 |
Area of application |
Railway industry |
|
Machine building |
|
Plant engineering |
Maximum power dissipation for nominal condition |
1.6 W |
Fuse |
G / 5 x 20 |
Fuse type |
Glass / ceramics / ... |
Rated surge voltage |
6 kV |
Degree of pollution |
3 |
Overvoltage category |
III |
Insulating material group |
I |
Maximum power dissipation |
max. 1.6 W (With single arrangement of the fuse terminal block in the event of overload) |
|
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) |
|
max. 4 W (With single arrangement of the fuse terminal block in the event of a short-circuit) |
|
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) |
Connection in acc. with standard |
IEC 60947-7-3 |
Maximum load current |
10 A (the current is determined by the fuse used) |
Nominal current IN |
6.3 A |
Nominal voltage UN |
500 V (The voltage is determined by the fuse or selected LED display) |
Rated operating voltage |
250 V |
Open side panel |
No |
Shock protection test specification |
DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection |
guaranteed |
Finger protection |
guaranteed |
Oscillation, broadband noise test result |
Test passed |
Test specification, oscillation, broadband noise |
DIN EN 50155 (VDE 0115-200):2008-03 |
Test spectrum |
Service life test category 1, class B, body mounted |
Test frequency |
f1 = 5 Hz to f2 = 150 Hz |
ASD level |
1.857 (m/s2)2/Hz |
Acceleration |
0,8 g |
Test duration per axis |
5 h |
Test directions |
X-, Y- and Z-axis |
Shock test result |
Test passed |
Test specification, shock test |
DIN EN 50155 (VDE 0115-200):2008-03 |
Shock form |
Semi-sinusoidal |
Acceleration |
5 g |
Shock duration |
30 ms |
Number of shocks per direction |
3 |
Test directions |
X-, Y- and Z-axis (pos. and neg.) |
Relative insulation material temperature index (Elec., UL 746 B) |
130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) |
125 °C |
Static insulating material application in cold |
-60 °C |
Behavior in fire for rail vehicles (DIN 5510-2) |
Test passed |
Flame test method (DIN EN 60695-11-10) |
V0 |
Oxygen index (DIN EN ISO 4589-2) |
>32 % |
NF F16-101, NF F10-102 Class I |
2 |
NF F16-101, NF F10-102 Class F |
2 |
Surface flammability NFPA 130 (ASTM E 162) |
passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) |
passed |
Smoke gas toxicity NFPA 130 (SMP 800C) |
passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) |
27,5 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 |
HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 |
HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 |
HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 |
HL 1 - HL 3 |