Magnescale LT11A-101B | Digital Gauge -Đồng hồ kỹ thuật số 1-Axis Màn hình LCD với ngõ ra Go/No Go và BCD

Magnescale LT11A-101B | Digital Gauge -Đồng hồ kỹ thuật số 1-Axis Màn hình LCD với ngõ ra Go/No Go và BCD

440
Nhà sản xuất: Magnescale;    Xuất xứ: Japan
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Đồng hồ kỹ thuật số Magnescale LT11A-101B | Digital Gauge

(1-Axis Màn hình LCD với ngõ ra Go/No Go và BCD)

Compact, lightweight, and easy-to-mount display unit for DT512


- Compact size : DIN standard (72 mm x 72mm / 2.83″ x 2.83″ W x H)
- Resolution: Selectable from 1, 5, 10 μm
- Suitable for panel mounting
- Direct interfacing from display unit to PLC or computer
- Current values, maximum, minimum, peak-to-peak values and GO/NO GO evaluation included as standard functions.
- ADD/SUB function (2-channel model)
- Full lineup for various applications
 

Specifications

Display  
I/O Measuring unit input 1 CH
I/O connectors*1
BCD*2
RS-232C*3
RS-TRG*4
Reset function Reset key or external input (I/O connectors)
BCD terminal
Preset function Preset value set with preset key, recalled with reset key.
Recalled with BCD reset terminal
Comparetor function Three-level comparator: Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
Up to 4 values can be set for comparator (key input). Switched with BCD terminal.
Peak Hold function Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
Resolution Selectable from 0.001 mm, 0.005 mm, 0.01 mm
Direction Can be switched
Reference point function Function use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed 100 m/min
Addition and subtraction function
Alarm Speed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
BCD alarm terminal “H” (OFF)
Data storage Resolution, direction, comparator value, preset value, modes, etc.
BCD sign
key lock function key lock and release.
Temperature Operating:0~40℃, Storage:-10~50℃
Power consumption*5 2.9W
Mass Approx. 230g
Power supply Power input connector (3 pins) : DC9.0-26.4 V
Compatible measuring unit DT512P/N
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.
Magnescale reserves the right to change product specifications without prior notice.


Tham khảo thêm các Model tương tự cùng loại:
Model

LT11A-101

Display 6 digit, backlight LCD, mode display
I/O Measuring unit input 1 CH
I/O connectors*1
BCD*2
RS-232C*3
RS-TRG*4
Reset function Reset key or external input (I/O connectors)
Preset function Preset value set with preset key, recalled with reset key.
Comparetor function Three-level comparator: Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
Peak Hold function Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
Resolution Selectable from 0.001 mm, 0.005 mm, 0.01 mm
Direction Can be switched
Reference point function Function use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed 100 m/min
Addition and subtraction function
Alarm Speed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
Data storage Resolution, direction, comparator value, preset value, modes, etc.
key lock function key lock and release.
Temperature Operating:0~40℃, Storage:-10~50℃
Power consumption*5 1.8W
Mass Approx. 200g
Power supply Power input connector (3 pins) : DC9.0-26.4 V
Compatible measuring unit DT512P/N
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.


Model

LT11A-101C

Display  
I/O Measuring unit input 1 CH
I/O connectors*1
BCD*2
RS-232C*3
RS-TRG*4
Reset function Reset key or external input (I/O connectors)
RS-232C command
Preset function Preset value set with preset key, recalled with reset key.
Set or recalled with RS-232C command
Comparetor function Three-level comparator: Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
Set with RS-232C command
Peak Hold function Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
RS-232C can set or start.
Resolution Selectable from 0.001 mm, 0.005 mm, 0.01 mm
Direction Can be switched
Reference point function Function use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed 100 m/min
Addition and subtraction function
Alarm Speed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
Data storage Resolution, direction, comparator value, preset value, modes, etc.
Data signaling rate, etc.
key lock function key lock and release.
Temperature Operating:0~40℃, Storage:-10~50℃
Power consumption*5 2.0W
Mass Approx. 220g
Power supply Power input connector (3 pins) : DC9.0-26.4 V
Compatible measuring unit DT512P/N
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.
Magnescale reserves the right to change product specifications without prior notice.


Model 

LT11A-201

Display  
I/O Measuring unit input 2 CH
I/O connectors*1
BCD*2
RS-232C*3
RS-TRG*4
Reset function Reset key or external input (I/O connectors)
Preset function Preset value set with preset key, recalled with reset key.
Comparetor function Three-level comparator: Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
Peak Hold function Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
Resolution Selectable from 0.001 mm, 0.005 mm, 0.01 mm
Direction Can be switched
Reference point function Function use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed 100 m/min
Addition and subtraction function A+B, A-B, B-A can be set with the direction setting.
Alarm Speed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
Data storage Resolution, direction, comparator value, preset value, modes, etc.
key lock function key lock and release.
Temperature Operating:0~40℃, Storage:-10~50℃
Power consumption*5 2.3W
Mass Approx. 210g
Power supply Power input connector (3 pins) : DC9.0-26.4 V
Compatible measuring unit DT512P/N
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.
Magnescale reserves the right to change product specifications without prior notice.


Model 

LT11A-201B

Display  
I/O Measuring unit input 2 CH
I/O connectors*1
BCD*2
RS-232C*3
RS-TRG*4
Reset function Reset key or external input (I/O connectors)
BCD terminal
Preset function Preset value set with preset key, recalled with reset key.
Recalled with BCD reset terminal
Comparetor function Three-level comparator: Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
Up to 4 values can be set for comparator (key input). Switched with BCD terminal.
Peak Hold function Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
Resolution Selectable from 0.001 mm, 0.005 mm, 0.01 mm
Direction Can be switched
Reference point function Function use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed 100 m/min
Addition and subtraction function A+B, A-B, B-A can be set with the direction setting.
Alarm Speed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
BCD alarm terminal “H” (OFF)
Data storage Resolution, direction, comparator value, preset value, modes, etc.
BCD sign
key lock function key lock and release.
Temperature Operating:0~40℃, Storage:-10~50℃
Power consumption*5 4.0W
Mass Approx. 270g
Power supply Power input connector (3 pins) : DC9.0-26.4 V
Compatible measuring unit DT512P/N
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.
Magnescale reserves the right to change product specifications without prior notice.


Model 

LT11A-201C

Display  
I/O Measuring unit input 2 CH
I/O connectors*1
BCD*2
RS-232C*3
RS-TRG*4
Reset function Reset key or external input (I/O connectors)
RS-232C command
Preset function Preset value set with preset key, recalled with reset key.
Set or recalled with RS-232C command
Comparetor function Three-level comparator: Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
Set with RS-232C command
Peak Hold function Maximum, minimum, and peak-to-peak values. Measuring started by the start input of the I/O connector; update stop by pause input.
RS-232C can set or start.
Resolution Selectable from 0.001 mm, 0.005 mm, 0.01 mm
Direction Can be switched
Reference point function Function use enabled/disabled can be selected (if use is enabled, the unit enters reference point signal input wait status at the same time as power-on).
Maximum response speed 100 m/min
Addition and subtraction function A+B, A-B, B-A can be set with the direction setting.
Alarm Speed over or measuring unit cable disconnected (Displayed on LCD or the I/O connector’s comparator outputs are all “H” (OFF).)
Data storage Resolution, direction, comparator value, preset value, modes, etc.
Data signaling rate, etc.
key lock function key lock and release.
Temperature Operating:0~40℃, Storage:-10~50℃
Power consumption*5 2.5W
Mass Approx. 230g
Power supply Power input connector (3 pins) : DC9.0-26.4 V
Compatible measuring unit DT512P/N
*1 I/O connector Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-232C models only) Output : Result evaluation (photocoupler)
*2 BCD (36 pin half-pitch connector) Input : Reset, peak-hold start, comparator value selection (4 settings) Output : five digits (open collector)One of current value/maximum value/minimum value/peak-to-peak value selected and output. Alarm output
*3 RS-232C (8 pin mini-DIN connector) Reset, preset value setting/recall, peak-hold start, peak-hold pause
*4 RS-TRG pin Trigger input for RS-232C data output
*5 With measuring unit connected.
Magnescale reserves the right to change product specifications without prior notice.
 

- Xem chi tiết Tài liệu kỹ thuật/ Datasheet Magnescale LT11A


Sản phẩm cùng loại
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại