Bo mạch mởi rộng Mitsubishi FX3G-2AD-BD | Analog input expansion board
(2 đầu vào analog 4-20mA 0-10V 12 bit)
Specifications
STARTUP AND MAINTENANCE PRECAUTIONS
- Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions.
+ For repair, contact your local Mitsubishi Electric representative.
- Do not drop the product or exert strong impact to it. Doing so may cause damage.
DISPOSAL PRECAUTIONS
- Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device.
TRANSPORTATION AND STORAGE PRECAUTIONS
The product is a precision instrument. During transportation, avoid impacts larger than those specified in the general specifications by using dedicated packaging boxes and shock-absorbing palettes. Failure to do so may cause failures in the product. After transportation, verify operation of the product and check for damage of the mounting part, etc.
Applicable PLC
Model name |
Applicability |
FX3S Series PLC |
Ver. 1.00 or later (from first production) |
FX3G Series PLC |
Ver. 1.10 or later |
The version number can be checked by monitoring D8001/D8101 as the last three digits indicate it.
- The number of connectable expansion boards varies depending on the main unit as
follows:
FX3S, FX3G-14M_, FX3G-24M_ Main units: 1 unit
FX3G-40M_, FX3G-60M_ Main units: 2 units
Never stack up two or more expansion boards.
For details on the system configuration, refer to the following manual.
--> FX3S/FX3G/FX3GC/FX3U/FX3UC Series User's Manual - Analog Control Edition
General Specifications
The general specifications are equivalent to the PLC main unit.
For general specifications, refer to the following manuals.
--> FX3S Series User's Manual - Hardware Edition
--> FX3G Series User's Manual - Hardware Edition
Performance Specifications
Voltage input
Analog input range 0 to 10 V DC (Input resistance: 198.7 kΩ)
Maximum absolute input -0.5 V, +15 V
Digital output 12 bits, binary
Resolution 2.5 mV (10 V/4000)
Total accuracy
+ ±0.5 % (±50 mV) for full scale of 10 V (when ambient temperature is 25 °C±5 °C)
+ ±1.0 % (±100 mV) for full scale of 10 V (when ambient temperature is 0 °C to 55 °C)
A/D conversion time 180 μs (The data will be updated at every scan time of the PLC.)
Input characteristics
Insulation method No insulation between each channel or the PLC.
Occupied points 0 point (This number is not related
Current input
Analog input range 4 to 20 mA DC (Input resistance: 250 Ω)
Maximum absolute input -2 mA, +30 mA
Digital output 11 bits, binary
Resolution 8 μA (16 mA/2000)
Total accuracy
A/D conversion time 180 μs (The data will be updated at every scan time of the PLC.)
Input characteristics
Insulation method No insulation between each channel or the PLC.
Occupied points 0 point (This number is not related