Phoenix Contact PLC-RSC- 24DC/21-21/EX - 2909509 | Relay Module -Rờ le PLC 8 chân 2PDTS 250V AC/DC 6A Coil 24VDC Ex

Phoenix Contact PLC-RSC- 24DC/21-21/EX - 2909509 | Relay Module -Rờ le PLC 8 chân 2PDTS 250V AC/DC 6A Coil 24VDC Ex

1,055
Nhà sản xuất: Phoenix Contact;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Chi tiết thông tin đặc tính sản phẩm

Rờ le Phoenix Contact PLC-RSC- 24DC/21-21/EX - 2909509

(Relay Module 8 chân 2PDTS 250V AC/DC 6A Coil 24VDC Ex)

 

Bản vẽ kỹ thuật


Diagram
Curve A
Maximum permissible continuous voltage Umax with limiting continuous current on the contact side (see relevant technical data)
Curve B
Minimum permissible operate voltage Uop after pre-excitation (see relevant technical data)


Diagram
Interrupting rating


Circuit diagram
 

Chú ý

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
 

Kích thước

Width 14 mm
Height 80 mm
Depth 94 mm
 

Ambient conditions

Ambient temperature (operation) -20 °C ... 60 °C (UL)
  -40 °C ... 60 °C (ATEX / IECEx)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Degree of protection RT III (Relay)
  IP20 (Relay base)
 

Thông số kỹ thuật cuộn coil/ Coil side

Nominal input voltage UN 24 V DC
Typical input current at UN 18 mA
Typical response time 8 ms
Typical release time 10 ms
Protective circuit Reverse polarity protection Polarity protection diode
  Free-wheeling diode Damping diode
Operating voltage display Yellow LED
Power dissipation for nominal condition 0.43 W
 

Thông số kỹ thuật tiếp điểm/ Contact side

Contact type 2 changeover contacts
Type of switch contact Single contact
Contact material AgNi
Maximum switching voltage 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage 5 V (at 10 mA)
Min. switching current 10 mA (At 5 V)
Maximum inrush current 15 A (300 ms)
Limiting continuous current 6 A
Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
  85 W (at 48 V DC)
  60 W (at 60 V DC)
  44 W (at 110 V DC)
  60 W (at 220 V DC)
  1500 VA (for 250 V AC)
Switching capacity 2 A (at 24 V, DC13)
  0.2 A (at 250 V, DC13)
  3 A (at 24 V, AC15)
  3 A (at 120 V, AC15)
  3 A (at 250 V, AC15)
 

Thông số chung/ General

Test voltage 4 kV AC (50 Hz, 1 min., winding/contact)
  2.5 kV AC (50 Hz, 1 min., changeover contact/changeover contact)
Operating mode 100% operating factor
Flammability rating according to UL 94 V0 (Housing)
Mechanical service life 3x 107 cycles
Mounting position any
Assembly instructions In rows with zero spacing
 

Thông số đấu nối/ Connection data

Connection name Coil side
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
  0.2 mm² ... 2.5 mm² (Single ferrule)
  2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
 

Connection data 2

Connection name Contact side
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
  0.2 mm² ... 2.5 mm² (Single ferrule)
  2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
 

Standards and Regulations

Designation Standards/regulations
Standards/regulations IEC 60664
  EN 50178
  EN 60079-0, -7, -15
Rated insulation voltage 250 V AC
Rated surge voltage 6 kV
Insulation Safe isolation, reinforced insulation
Pollution degree 2
Overvoltage category III
 

Conformance/approvals

Designation CE
Identification CE-compliant
Designation ATEX
Identification  II 3G Ex ec nC IIC T4 Gc
Certificate IBExU16ATEXB015 X
Designation IECEx
Identification Ex ec nC IIC T4 Gc
Certificate IECEx IBE 16.0029X
Designation UL, USA
Identification Class I, Zone 2, AEx nA nC IIC T6
Designation UL, USA/Canada
Identification Class I, Div. 2, Groups A, B, C, D
Designation UL, Canada
Identification Class I, Zone 2, Ex nA nC IIC Gc T6 X
Designation Corrosive gas test
Identification ISA-S71.04. G3 Harsh Group
  EN 60068-2-60
 

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
 

Classifications

eCl@ss

eCl@ss 10.0.1 27371601
eCl@ss 11.0 27371601
eCl@ss 5.0 27371600
eCl@ss 5.1 27371600
eCl@ss 6.0 27371600
eCl@ss 7.0 27371601
eCl@ss 9.0 27371601
 

ETIM

ETIM 2.0 EC001437
ETIM 3.0 EC001437
ETIM 4.0 EC001437
ETIM 5.0 EC001437
ETIM 6.0 EC001437
ETIM 7.0 EC001437
 

UNSPSC

UNSPSC 6.01 30211916
UNSPSC 7.0901 39121515
UNSPSC 11 39121515
UNSPSC 12.01 39121515
UNSPSC 13.2 39122334
UNSPSC 18.0 39122334
UNSPSC 19.0 39122334
UNSPSC 20.0 39122334
UNSPSC 21.0 39122334
 

- Xem chi tiết Thông số kỹ thuật/ Datasheet Rờ le Phoenix Contact PLC-RSC- 24DC/21-21/EX - 2909509


Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại