Rờ le an toàn Phoenix Contact PSR-SCP- 24DC/ESD/4X1/30 - 2981800 | Safety relays

(24VDC DPST-NO PSR 6A Screw)

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts with dropout delay of 0.1 s to 30 s, plug-in screw connection terminal block

 

Drawings


Circuit diagram


Circuit diagram
Two-channel emergency stop monitoring


Circuit diagram
Light grid monitoring


Circuit diagram
Two-channel safety door monitoring

 

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
 

Dimensions

Width 22.5 mm
Height 99 mm
Depth 114.5 mm
 

Ambient conditions

Ambient temperature (operation) -20 °C ... 45 °C
Ambient temperature (storage/transport) -40 °C ... 70 °C
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Maximum altitude ≤ 2000 m (Above sea level)
 

Input data

Rated control circuit supply voltage US  
Nominal input voltage UN 24 V DC
Input voltage range in reference to UN 0.85 ... 1.1
Typical input current at UN 75 mA DC
Voltage at input/start and feedback circuit approx. 24 V DC
Typical response time 150 ms (Monitored/manual and auto-start)
Typical release time 20 ms (Undelayed contacts)
  100 ms (delayed contacts)
Typical release time range 0.1 s ... 30 s
Recovery time 330 ms (Restart)
  1 s (Electric torque)
Operating voltage display Green LED
Status display LED K1/K2 and K3(t)/K4(t), green
Protective circuit Suppressor diode, 33 V DC
Max. permissible overall conductor resistance 500 Ω (Input and reset circuit at UN)
 

Output data

Contact type 4 enabling current paths
Contact material AgSnO2
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 15 V AC/DC
Limiting continuous current 6 A (N/O contact)
Maximum inrush current 6 A
Inrush current, minimum 25 mA
Sq. Total current 120 A2 (see to derating)
Interrupting rating (ohmic load) max. 144 W (24 V DC, τ = 0 ms)
  288 W (48 V DC, τ = 0 ms)
  90 W (110 V DC, τ = 0 ms)
  88 W (220 V DC, τ = 0 ms)
  1500 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load) 42 W (24 V DC, τ = 40 ms)
  33 W (48 V DC, τ = 40 ms)
  25 W (110 V DC, τ = 40 ms)
  23 W (220 V DC, τ = 40 ms)
Switching capacity min. 0.4 W
Mechanical service life approx. 107 cycles
Switching capacity (360/h cycles) on request
Output fuse 10 A gL/gG NEOZED (N/O contact)
 

General

Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Nominal operating mode 100% operating factor
Net weight 198.9 g
Mounting position any
Mounting type DIN rail mounting
Degree of protection IP20
Min. degree of protection of inst. location IP54
Housing material Polyamide
 

Connection data

Connection method Screw connection
pluggable Yes
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG 24 ... 12
Stripping length 7 mm
Screw thread M3
 

Safety-related characteristic data

Stop category in accordance with IEC 60204 0
  1
Safety Integrity Level (SIL) 3
Designation EN ISO 13849
Performance level (PL) e
Category 4
Designation EN 62061
Safety Integrity Level (SIL) 3
 

Standards and Regulations

Designation Air clearances and creepage distances between the power circuits
Standards/regulations DIN EN 60947-1
Rated insulation voltage 250 V
Rated surge voltage/insulation 4 kV / basic insulation
Degree of pollution 2
Overvoltage category II
Shock 15g
Vibration (operation) 10 Hz ... 150 Hz, 2g
 

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
 

Classifications

ECLASS

ECLASS 10.0.1 27371819
ECLASS 11.0 27371819
ECLASS 4.0 40020600
ECLASS 4.1 40020600
ECLASS 5.0 27371900
ECLASS 5.1 27371900
ECLASS 6.0 27371800
ECLASS 7.0 27371819
ECLASS 9.0 27371819
 

ETIM

ETIM 2.0 EC001449
ETIM 3.0 EC001449
ETIM 4.0 EC001449
ETIM 6.0 EC001449
ETIM 7.0 EC001449
 

UNSPSC

UNSPSC 6.01 30211901
UNSPSC 7.0901 39121501
UNSPSC 11 39121501
UNSPSC 12.01 39121501
UNSPSC 13.2 39121501
UNSPSC 18.0 39122205
UNSPSC 19.0 39122205
UNSPSC 20.0 39122205
UNSPSC 21.0 39122205
 

- Xem chi tiết Tài liệu kỹ thuật/ Datasheet Phoenix Contact PSR-SCP- 24DC/ESD/4X1/30 - 2981800