Rờ le an toàn giám sát cửa Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 - 2981428 | Safety relays
(SIL3 Cat.4 3NO 1NC 2NO 0.2-300s 250V AC/DC 6A Coil 24VDC)
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e (EN ISO 13849), one- or two-channel operation, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with dropout delay of 0.2 s to 300 s, plug-in screw terminal block
Your advantages
- Maximum of 3 undelayed and 2 dropout delay contacts
- Manually monitored and automatic activation
- Up to Cat. 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
- For emergency stop and safety door monitoring, plus evaluation of light grids
- Single and two-channel control
- Adjustable delay time of 0.2 s ... 300 s (24 increments)
- Protective labels to prevent manipulation of the set time (PSR-ESD-300) or electronic protection against manipulation (PSR-ESD-30)
Bản vẽ kỹ thuật

Circuit diagram

Circuit diagram
Two-channel safety door monitoring
Note
| Utilization restriction |
EMC: class A product, see manufacturer's declaration in the download area |
Dimensions
| Width |
45 mm |
| Height |
99 mm |
| Depth |
114.5 mm |
Ambient conditions
| Ambient temperature (operation) |
-20 °C ... 55 °C (observe derating) |
| Ambient temperature (storage/transport) |
-40 °C ... 70 °C |
| Max. permissible relative humidity (operation) |
75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) |
75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude |
≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US |
24 V DC -15 % / +10 % |
| Rated control supply current IS |
typ. 155 mA |
| Power consumption at US |
typ. 3.72 W |
| Inrush current |
200 mA (at US) |
| |
< 40 mA (with Us/Ix to S10) |
| |
< 150 mA (with Us/Ix to S12) |
| |
> -60 mA (with Us/Ix to S22) |
| |
< 40 mA (with Us/Ix to S34) |
| |
< 40 mA (with Us/Ix to S35) |
| Current consumption |
< 40 mA (with Us/Ix to S10) |
| |
< 50 mA (with Us/Ix to S12) |
| |
> -40 mA (with Us/Ix to S22) |
| |
0 mA (with Us/Ix to S34) |
| |
< 5 mA (with Us/Ix to S35) |
| Voltage at input/start and feedback circuit |
24 V DC -15 % / +10 % |
| Typical response time |
< 600 ms (automatic start) |
| |
< 70 ms (manual start) |
| Typ. starting time with Us |
< 600 ms (when controlled via A1) |
| Typical release time |
< 20 ms (when controlled via S11/S12 and S21/S22) |
| |
< 20 ms (when controlled via A1) |
| Concurrence |
∞ |
| Recovery time |
< 1 s |
| Operating voltage display |
1 x green LED |
| Status display |
4 x green LEDs |
| Protective circuit |
Surge protection Suppressor diode |
| Maximum switching frequency |
0.5 Hz |
| Max. permissible overall conductor resistance |
approx. 22 Ω (Input and start circuits at US) |
| Filter time |
1 ms (at A1 in the event of voltage dips at Us) |
| |
max. 1.5 ms (at S10, S12; test pulse width) |
| |
7.5 ms (at S10, S12; test pulse rate) |
| |
Test pulse rate = 5 x Test pulse width |
Output data
| Contact type |
5 enabling current paths |
| |
1 signaling current path |
| Contact material |
AgSnO2 |
| Maximum switching voltage |
250 V AC/DC (Observe the load curve) |
| Minimum switching voltage |
5 V AC/DC |
| Limiting continuous current |
6 A (N/O contact, pay attention to the derating) |
| |
6 A (N/C contact) |
| Maximum inrush current |
20 A (Δt 100 ms, undelayed contacts) |
| |
8 A (delayed contacts) |
| Inrush current, minimum |
10 mA |
| Sq. Total current |
55 A2 (observe derating) |
| Interrupting rating (ohmic load) max. |
144 W (24 V DC, τ = 0 ms) |
| |
288 W (48 V DC, τ = 0 ms) |
| |
110 W (110 V DC, τ = 0 ms, delayed contacts: 77 W) |
| |
88 W (220 V DC, τ = 0 ms) |
| |
1500 VA (250 V AC, τ = 0 ms, delayed contacts: 2000 VA) |
| Maximum interrupting rating (inductive load) |
42 W (24 V DC, τ = 40 ms, delayed contacts: 48 W) |
| |
42 W (48 V DC, τ = 40 ms, delayed contacts: 40 W) |
| |
42 W (110 V DC, τ = 40 ms, delayed contacts: 35 W) |
| |
42 W (220 V DC, τ = 40 ms, delayed contacts: 33 W) |
| Switching capacity min. |
50 mW |
| Mechanical service life |
10x 106 cycles |
| Switching capacity (360/h cycles) |
4 A (24 V DC) |
| |
4 A (230 V AC) |
| Output fuse |
10 A gL/gG (N/O contact) |
| |
6 A gL/gG (N/C contact) |
General
| Relay type |
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Nominal operating mode |
100% operating factor |
| Net weight |
430 g |
| Mounting position |
any |
| Mounting type |
DIN rail mounting |
| Degree of protection |
IP20 |
| Min. degree of protection of inst. location |
IP54 |
| Housing material |
PBT |
| Housing color |
yellow |
Connection data
| Connection method |
Screw connection |
| pluggable |
Yes |
| Conductor cross section solid |
0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG |
24 ... 12 |
| Stripping length |
7 mm |
| Screw thread |
M3 |
Safety-related characteristic data
| Stop category in accordance with IEC 60204 |
0 |
| |
1 |
| Designation |
IEC 61508 - High demand |
| Safety Integrity Level (SIL) |
3 (for delayed contacts SIL 2) |
| Designation |
IEC 61508 - Low demand |
| Safety Integrity Level (SIL) |
3 (for delayed contacts SIL 2) |
| Designation |
EN ISO 13849 |
| Performance level (PL) |
e (for delayed contacts PL d) |
| Category |
4 (Undelayed contacts) |
| |
3 (delayed contacts) |
| Designation |
EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) |
3 (for delayed contacts SILCL 2) |
Standards and Regulations
| Designation |
Air clearances and creepage distances between the power circuits |
| Standards/regulations |
DIN EN 50178/VDE 0160 |
| Rated insulation voltage |
250 V AC |
| Rated surge voltage/insulation |
Basic insulation 4 kV:
between all current paths and housing
Safe isolation, reinforced insulation 6 kV:
between 13/14, 23/24, 33/34, and the remaining current paths
between 13/14, 23/24, 33/34 among one another |
| Degree of pollution |
2 |
| Overvoltage category |
III |
| Shock |
15g |
| Vibration (operation) |
10 Hz ... 150 Hz, 2g |
| Conformance |
CE-compliant |
Environmental Product Compliance
| REACh SVHC |
Lead 7439-92-1 |
| China RoHS |
Environmentally Friendly Use Period = 50 years |
| |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
ECLASS
| ECLASS 10.0.1 |
27371819 |
| ECLASS 11.0 |
27371819 |
| ECLASS 4.0 |
40020600 |
| ECLASS 4.1 |
40020600 |
| ECLASS 5.0 |
27371900 |
| ECLASS 5.1 |
27371900 |
| ECLASS 6.0 |
27371800 |
| ECLASS 7.0 |
27371819 |
| ECLASS 9.0 |
27371819 |
ETIM
| ETIM 2.0 |
EC001449 |
| ETIM 3.0 |
EC001449 |
| ETIM 4.0 |
EC001449 |
| ETIM 6.0 |
EC001449 |
| ETIM 7.0 |
EC001449 |
UNSPSC
| UNSPSC 6.01 |
30211901 |
| UNSPSC 7.0901 |
39121501 |
| UNSPSC 11 |
39121501 |
| UNSPSC 12.01 |
39121501 |
| UNSPSC 13.2 |
39121501 |
| UNSPSC 18.0 |
39122205 |
| UNSPSC 19.0 |
39122205 |
| UNSPSC 20.0 |
39122205 |
| UNSPSC 21.0 |
39122205 |