Thông tin chi tiết của sản phẩm
Cầu đấu điện vặn vít Phoenix Contact UT 4 - 3044102
(Feed-through terminal block 1000V 32A 1 tầng 0.14-6mm²)
Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, connection method: Screw connection, number of connections: 2, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, height: 46.9 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Ưu điểm
- The large wiring space enables the connection of solid and stranded conductors without ferrules, even above the nominal cross section
- As well as saving space, the compact design enables user-friendly wiring in a small amount of space
- Optimum screwdriver guidance through closed screw shafts
- The cable entry funnel enables the use of conductors with ferrules and plastic collars within the nominal cross section
- Tested for railway applications
Thông số kỹ thuật chung
Number of levels |
1 |
Number of connections |
2 |
Potentials |
1 |
Nominal cross section |
4 mm² |
Color |
gray |
Insulating material |
PA |
Flammability rating according to UL 94 |
V0 |
Area of application |
Railway industry |
|
Machine building |
|
Plant engineering |
|
Process industry |
Rated surge voltage |
8 kV |
Degree of pollution |
3 |
Overvoltage category |
III |
Insulating material group |
I |
Maximum power dissipation for nominal condition |
1.02 W |
Maximum load current |
41 A (with 6 mm² conductor cross section) |
Nominal current IN |
32 A (with 4 mm² conductor cross section) |
Nominal voltage UN |
1000 V |
Open side panel |
Yes |
Ambient temperature (operation) |
-60 °C ... 105 °C (max. short-term operating temperature 130°C) |
Ambient temperature (storage/transport) |
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Permissible humidity (storage/transport) |
30 % ... 70 % |
Ambient temperature (assembly) |
-5 °C ... 70 °C |
Ambient temperature (actuation) |
-5 °C ... 70 °C |
Shock protection test specification |
DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection |
guaranteed |
Finger protection |
guaranteed |
Result of surge voltage test |
Test passed |
Result of power-frequency withstand voltage test |
Test passed |
Power frequency withstand voltage setpoint |
2.2 kV |
Result of the test for mechanical stability of terminal points (5 x conductor connection) |
Test passed |
Result of bending test |
Test passed |
Bending test rotation speed |
10 rpm |
Bending test turns |
135 |
Bending test conductor cross section/weight |
0.14 mm² / 0.2 kg |
|
4 mm² / 0.9 kg |
|
6 mm² / 1.4 kg |
Tensile test result |
Test passed |
Result of tight fit on support |
Test passed |
Tight fit on carrier |
NS 35 |
Setpoint |
1 N |
Result of voltage-drop test |
Test passed |
Result of temperature-rise test |
Test passed |
Requirement temperature-rise test |
Increase in temperature ≤ 45 K |
Short circuit stability result |
Test passed |
Conductor cross section short circuit testing |
4 mm² |
Short-time current |
0.48 kA |
Conductor cross section short circuit testing |
6 mm² |
Short-time current |
0.72 kA |
Result of thermal test |
Test passed |
Proof of thermal characteristics (needle flame) effective duration |
30 s |
Oscillation, broadband noise test result |
Test passed |
Test specification, oscillation, broadband noise |
DIN EN 50155 (VDE 0115-200):2008-03 |
Test spectrum |
Service life test category 1, class B, body mounted |
Test frequency |
f1 = 5 Hz to f2 = 150 Hz |
ASD level |
1.857 (m/s2)2/Hz |
Acceleration |
0,8 g |
Test duration per axis |
5 h |
Test directions |
X-, Y- and Z-axis |
Shock test result |
Test passed |
Test specification, shock test |
DIN EN 50155 (VDE 0115-200):2008-03 |
Shock form |
Half-sine |
Acceleration |
5g |
Shock duration |
30 ms |
Number of shocks per direction |
3 |
Test directions |
X-, Y- and Z-axis (pos. and neg.) |
Relative insulation material temperature index (Elec., UL 746 B) |
130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) |
125 °C |
Static insulating material application in cold |
-60 °C |
Surface flammability NFPA 130 (ASTM E 162) |
passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) |
passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) |
27,5 MJ/kg |
Smoke gas toxicity NFPA 130 (SMP 800C) |
passed |
Fire protection for rail vehicles (DIN EN 45545-2) R22 |
HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 |
HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 |
HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 |
HL 1 - HL 3 |
Kích thước
Width |
6.2 mm |
End cover width |
2.2 mm |
Length |
47.7 mm |
Height |
46.9 mm |
Height NS 35/7,5 |
47.5 mm |
Height NS 35/15 |
55 mm |
Thông số đấu nối
Connection method |
Screw connection |
Screw thread |
M3 |
Stripping length |
9 mm |
Tightening torque, min |
0.6 Nm |
Tightening torque max |
0.8 Nm |
Connection in acc. with standard |
IEC 60947-7-1 |
Note |
Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. |
Conductor cross section solid min. |
0.14 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section AWG min. |
26 |
Conductor cross section AWG max. |
10 |
Conductor cross section flexible min. |
0.14 mm² |
Conductor cross section flexible max. |
6 mm² |
Min. AWG conductor cross section, flexible |
26 |
Max. AWG conductor cross section, flexible |
10 |
Conductor cross section flexible, with ferrule without plastic sleeve min. |
0.14 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. |
4 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. |
0.14 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. |
4 mm² |
2 conductors with same cross section, solid min. |
0.14 mm² |
2 conductors with same cross section, solid max. |
1.5 mm² |
2 conductors with same cross section, stranded min. |
0.14 mm² |
2 conductors with same cross section, stranded max. |
1.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum |
0.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum |
2.5 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum |
0.14 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum |
1.5 mm² |
Connection in acc. with standard |
IEC/EN 60079-7 |
Conductor cross section solid min. |
0.14 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section AWG min. |
26 |
Conductor cross section AWG max. |
10 |
Conductor cross section flexible min. |
0.14 mm² |
Conductor cross section flexible max. |
4 mm² |
Internal cylindrical gage |
A4 |
Standards and Regulations
Connection in acc. with standard |
CSA |
|
IEC 60947-7-1 |
|
IEC/EN 60079-7 |
Flammability rating according to UL 94 |
V0 |
Environmental Product Compliance
REACh SVHC |
Lead 7439-92-1 |
China RoHS |
Environmentally Friendly Use Period = 50 years |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
eCl@ss 10.0.1 |
27141120 |
eCl@ss 11.0 |
27141120 |
eCl@ss 4.0 |
27141100 |
eCl@ss 4.1 |
27141100 |
eCl@ss 5.0 |
27141100 |
eCl@ss 5.1 |
27141100 |
eCl@ss 6.0 |
27141100 |
eCl@ss 7.0 |
27141120 |
eCl@ss 8.0 |
27141120 |
eCl@ss 9.0 |
27141120 |
ETIM
ETIM 2.0 |
EC000897 |
ETIM 3.0 |
EC000897 |
ETIM 4.0 |
EC000897 |
ETIM 5.0 |
EC000897 |
ETIM 6.0 |
EC000897 |
ETIM 7.0 |
EC000897 |
UNSPSC
UNSPSC 6.01 |
30211811 |
UNSPSC 7.0901 |
39121410 |
UNSPSC 11 |
39121410 |
UNSPSC 12.01 |
39121410 |
UNSPSC 13.2 |
39121410 |
UNSPSC 18.0 |
39121410 |
UNSPSC 19.0 |
39121410 |
UNSPSC 20.0 |
39121410 |
UNSPSC 21.0 |
39121410 |