Chi tiết thông tin đặc tính sản phẩm
Relay module rơle PLC-RSC 1PDT 250v AC/DC 24vDC 6A - Phoenix Contact - Relay Module - PLC-RPT- 24DC/ 1IC/ACT - 2900298
Bản vẽ kỹ thuật
Diagram
Curve A
Maximum permissible continuous voltage Umax with limiting continuous current on the contact side (see relevant technical data)
Curve B
Minimum permissible operate voltage Uop after pre-excitation (see relevant technical data)
Diagram
Interrupting rating
Diagram
Basic behavior of capacitive loads:
- Very high inrush current
- Voltage increases with an e-function
Circuit diagram
Chú ý
Utilization restriction |
EMC: class A product, see manufacturer's declaration in the download area |
Thông số kích thước
Width |
14 mm |
Height |
80 mm |
Depth |
94 mm |
Thông số điều kiện môi trường hoạt động
Ambient temperature (operation) |
-40 °C ... 60 °C |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Thông số cuộn dây
Nominal input voltage UN |
24 V DC |
Typical input current at UN |
18 mA |
Typical response time |
8 ms |
Typical release time |
10 ms |
Protective circuit |
Reverse polarity protection Polarity protection diode |
|
Free-wheeling diode Damping diode |
Operating voltage display |
Yellow LED |
Power dissipation for nominal condition |
0.43 W |
Thông số Contact side
Contact type |
1 N/O contact |
Type of switch contact |
Single contact |
Contact material |
AgSnO |
Maximum switching voltage |
250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum switching voltage |
12 V (at 100 mA) |
Min. switching current |
100 mA (at 12 V DC) |
Maximum inrush current |
80 A (20 ms) |
|
130 A (peak, at capacitive load, 230 V AC, 24 μF) |
Limiting continuous current |
6 A |
|
10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged) |
Interrupting rating (ohmic load) max. |
144 W (at 24 V DC) |
|
58 W (at 48 V DC) |
|
48 W (at 60 V DC) |
|
50 W (at 110 V DC) |
|
80 W |
|
85 W (for 250 V DC) |
|
1500 VA (for 250 V AC) |
Interrupting rating (ohmic load) max. bridged |
240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
|
2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
Switching capacity min. |
1200 mW |
Switching capacity |
2 A (at 24 V, DC13) |
|
0.2 A (at 110 V, DC13) |
|
0.2 A (at 250 V, DC13) |
|
6 A (at 24 V, AC15) |
|
6 A (at 120 V, AC15) |
|
6 A (at 250 V, AC15) |
Thông số kết nối dữ liệu đầu vào
Connection name |
Coil side |
Connection method |
Push-in connection |
Stripping length |
8 mm |
Conductor cross section solid |
0.14 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.14 mm² ... 2.5 mm² |
|
0.2 mm² ... 2.5 mm² () |
|
2x 0.5 mm² ... 1 mm² () |
Conductor cross section AWG |
26 ... 14 |
Thông số kết nối dữ liệu đầu ra
Connection name |
Contact side |
Connection method |
Push-in connection |
Stripping length |
8 mm |
Conductor cross section solid |
0.14 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.14 mm² ... 2.5 mm² |
|
0.2 mm² ... 2.5 mm² () |
|
2x 0.5 mm² ... 1 mm² () |
Conductor cross section AWG |
26 ... 14 |
Thông số chung
Note |
Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. |
|
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
|
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. |
|
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
Test voltage relay winding/relay contact |
4 kV AC (50 Hz, 1 min.) |
Operating mode |
100% operating factor |
Degree of protection |
RT II (Relay) |
|
IP20 (Relay base) |
Mechanical service life |
3x 107 cycles |
Mounting position |
any |
Assembly instructions |
In rows with zero spacing |
Các quy chuẩn đạt được
Connection in acc. with standard |
CUL |
Designation |
Standards/regulations |
Standards/regulations |
EN 50178 |
|
EN 61810-1 |
Rated insulation voltage |
250 V AC |
Rated surge voltage |
6 kV |
Insulation |
Safe isolation, reinforced insulation |
Degree of pollution |
2 |
Overvoltage category |
III |
Flammability rating according to UL 94 |
V0 |
Tiêu chuẩn thân thiện môi trường
China RoHS |
Environmentally Friendly Use Period = 50 |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Các bộ phận cấu thành
Relay base PLC-BPT- 24DC/ 1IC/ACT 2900260
14 mm PLC basic terminal block for high switch-on currents with push-in connection, without relay or solid-state relay, for mounting on DIN rail NS 35/7,5, with load return line connection (BB), 1 N/O contact, input voltage 24 V DC
Single relay REL-MR- 24DC/1IC 2961341
Plug-in miniature power relay, with power contact for high switch-on currents, 1 N/O contact, input voltage 24 V DC
Approvals