Rơ le an toàn 2-Kênh NO PNP SIL3 CAT4 Sick RLY3-EMSS300 | 1099973
Features
Applications |
Evaluation unit |
Compatible sensor types |
Safety sensors with potential-free outputs |
Safety-related parameters
Safety integrity level |
SIL3 (IEC 61508) |
Category |
Category 4 (ISO 13849-1) |
Performance level |
PL e (ISO 13849-1) |
PFHD (mean probability of a dangerous failure per hour) |
1.0 x 10-9 |
TM (mission time) |
20 years (ISO 13849-1) |
Stop category |
0 (IEC 60204-1) |
Functions
Sensor monitoring |
Discrepancy monitoring
Cross-circuit detection
|
Restart interlock |
✔ |
Reset |
Automatic
Manual
|
External device monitoring (EDM) |
✔ |
Interfaces
Connection type |
Front connector with spring terminals |
Inputs |
2 safety inputs
1 input for reset pushbutton or external device monitoring (EDM)
|
Outputs |
3 enabling current paths (safe)
2 application diagnostic outputs (not safe)
3 test pulse outputs (not safe)
|
Display elements |
LEDs |
Configuration method |
Hard wired |
Electrical data - Operating data
Voltage supply |
PELV or SELV |
Supply voltage VS |
24 V DC (16.8 V ... 30 V) |
Residual ripple |
≤ 2.4 V |
Power consumption |
≤ 2.5 W (DC) |
Electrical data - Safety inputs
Number |
2 |
Input voltage |
|
HIGH |
24 V DC (11 V ... 30 V) |
LOW |
0 V DC (–3 V ... 5 V) |
|
Input current |
4 mA ... 6 mA |
Activation time tolerance between the two start buttons |
≤ 3 s |
Electrical data - Reset pushbutton or external device monitoring (EDM) input
Number |
1 |
Input voltage |
|
HIGH |
24 V DC (11 V ... 30 V) |
LOW |
0 V DC (–3 V ... 5 V) |
|
Input current |
4 mA ... 6 mA |
Electrical data - Enabling current paths
Response time |
12 ms |
Number |
3 |
Type of output |
N/O contacts, positively guided |
Contact material |
Silver alloy, gold flashed |
Switching voltage |
10 V AC ... 230 V AC
10 V DC ... 230 V DC
|
Switching current |
10 mA ... 6 A |
Total current |
12 A |
Mechanical life |
1 x 107 switching cycles |
Overvoltage category |
III (EN 60664-1) |
Rated impulse withstand voltage Uimp |
6 kV (EN 60664-1) |
Electrical data - Application diagnostic outputs
Number |
2 |
Type of output |
Push-pull semiconductor output, short-circuit protected |
Output voltage |
|
HIGH |
≥ Vs – 3 V |
LOW |
≤ 3 V |
|
Input current (NPN) |
≤ 15 mA |
Output current (PNP) |
≤ 120 mA |
Electrical data - Test pulse outputs
Number |
3 |
Type of output |
PNP semiconductors, short-circuit protected |
Output voltage |
≥ Vs – 3 V |
Test pulse width |
2 ms |
Test pulse interval |
40 ms |
Mechanical data
Dimensions (W x H x D) |
18 mm x 124.6 mm x 85.5 mm |
Weight |
150 g |
Ambient data
Enclosure rating |
IP20 (IEC 60529) |
Ambient operating temperature |
–25 °C ... +55 °C |
Storage temperature |
–25 °C ... +70 °C |
Air humidity |
≤ 95 %, Non-condensing |
Interference emission |
According to IEC 61000-6-4 |
Interference resistance |
According to IEC 61326-3-1
According to IEC 61000-6-2
According to IEC 60947-5-1
|
Classifications
eCl@ss 5.0 |
27371990 |
eCl@ss 5.1.4 |
27371990 |
eCl@ss 6.0 |
27371819 |
eCl@ss 6.2 |
27371819 |
eCl@ss 7.0 |
27371819 |
eCl@ss 8.0 |
27371819 |
eCl@ss 8.1 |
27371819 |
eCl@ss 9.0 |
27371819 |
eCl@ss 10.0 |
27371819 |
eCl@ss 11.0 |
27371819 |
eCl@ss 12.0 |
27371819 |
ETIM 5.0 |
EC001449 |
ETIM 6.0 |
EC001449 |
ETIM 7.0 |
EC001449 |
ETIM 8.0 |
EC001449 |
UNSPSC 16.0901 |
41113704 |
- Tài liệu kỹ thuật Sick RLY3-EMSS300 | 1099973
ở đây.
Tham khảo các model khác cùng loại:
RLY3-MULT100
Part no.: 1100692
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Safety sensors with OSSDs, Safety sensors with test input, safety sensors with potential-free outputs, Safety pressure mats
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 2 test pulse outputs (not safe)
Housing width: 18 mm
RLY3-LOOP100
Part no.: 1100696
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Flexi Loop safe series connection
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
Housing width: 18 mm
RLY3-HAND100
Part no.: 1085346
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Two-hand controls Type III C, in accordance with EN 574
Connection type: Front connector with spring terminals
Restart interlock: no
External device monitoring (EDM): Integrated
Outputs: 2 enabling current paths (safe), 1 application diagnostic output (not safe)
Housing width: 18 mm
RLY3-EMSS100
Part no.: 1085345
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Safety sensors with potential-free outputs
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Housing width: 18 mm
RLY3-OSSD300
Part no.: 1099969
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Safety sensors with OSSDs
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
Housing width: 18 mm
RLY3-TIME100
Part no.: 1100688
Safety relays
ReLy
Applications: Evaluation unit for stop category 1 applications
Compatible sensor types: Safety sensors with OSSDs, safety sensors with potential-free outputs
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Housing width: 18 mm
RLY3-EMSS300
Part no.: 1099973
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Safety sensors with potential-free outputs
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Housing width: 18 mm
RLY3-OSSD200
Part no.: 1085344
Safety relays
ReLy
Applications: Evaluation unit
Compatible sensor types: Safety sensors with OSSDs
Connection type: Front connector with spring terminals
Restart interlock: yes
External device monitoring (EDM): Integrated
Outputs: 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
Housing width: 18 mm
RLY3-OSSD100
Part no.: 1085343
Safety relays
ReLy
Applications: Output expansion module for OSSDs
Compatible sensor types: Safety sensors with OSSDs
Connection type: Front connector with spring terminals
Restart interlock: no
External device monitoring (EDM): Via path
Outputs: 2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe)
Housing width: 18 mm
RLY3-OSSD400
Part no.: 1099971
Safety relays
ReLy
Applications: Output expansion module for OSSDs
Compatible sensor types: Safety sensors with OSSDs
Connection type: Front connector with spring terminals
Restart interlock: no
External device monitoring (EDM): Via path
Outputs: 4 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe), 1 signaling current path (not safe)
Housing width: 28 mm