Bộ chuyển phát tín hiệu nhiệt độ Siemens 7NG0320-0BA00-0AA0
Product |
Article Number (Market Facing Number) |
7NG0320-0BA00-0AA0 |
Product Description |
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC, EAC, CSA) None (head mounted and rail mounted transmitter) Without local operation |
Product family |
SITRANS TR320 (HART, universal) |
Product Lifecycle (PLM) |
PM300:Active Product |
Price data |
Price Group / Headquarter Price Group |
8T1 |
List Price |
Show prices |
Customer Price |
Show prices |
Metal Factor |
None |
Delivery information |
Export Control Regulations |
ECCN : EAR99 / AL : N |
Standard lead time ex-works |
300 Day/Days |
Net Weight (kg) |
0.500 Kg |
Package size unit of measure |
Not available |
Quantity Unit |
1 Piece |
Packaging Quantity |
1 |
Additional Product Information |
EAN |
Not available |
UPC |
Not available |
Commodity Code |
Not available |
LKZ_FDB/ CatalogID |
FI01-2 |
Product Group |
4782 |
Group Code |
R3P0 |
Country of origin |
France |
Compliance with the substance restrictions according to RoHS directive |
Since: 20/03/18 |
Product class |
C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
WEEE (2012/19/EU) Take-Back Obligation |
Yes |
REACH Art. 33 Duty to inform according to the current list of candidates |
|
Classifications |
|
|
Version |
Classification |
eClass |
12 |
27-20-02-06 |
eClass |
6 |
27-20-02-06 |
eClass |
7.1 |
27-20-02-06 |
eClass |
8 |
27-20-02-06 |
eClass |
9 |
27-20-02-06 |
eClass |
9.1 |
27-20-02-06 |
ETIM |
7 |
EC002919 |
ETIM |
8 |
EC002919 |
|
Tham khảo thêm các model khác cùng loại:
7NG032.-.....-....
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output.
7NG0320-0BA00-0AA0-Z Y01
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC, EAC, CSA) None (head mounted and rail mounted transmitter) Without local operation Measuring range setting temperature input: Lower range value (max. 5 characters), Upper range value (max. 5 characters), Unit (C, F) (on type label)
7NG0320-0BA00-0AA0
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output.
7NG0320-0JA10-0AA0-Z C11+C20+Y01+Y15
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 TC Type K None Internal CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC, EAC, CSA) None (head mounted and rail mounted transmitter) Without local operation Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Functional Safety (IEC 61508) - SIL2/3 Measuring range setting temperature input: Lower range value (max. 5 characters), Upper range value (max. 5 characters), Unit (C, F) (on type label) Tag (device parameters, max. 32 characters), adhesive label
7NG0320-0LA10-0NA0-Z Y01
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 TC Type N None Internal CJC Without enclosure (head mounted and rail mounted transmitter) - Intrinsic safety (Ex i) / Increased safety zone 2 (Ex ec) / Non-incendive (NI) / Non-incendive field wiring (NIFW) (ATEX, IECEx, EACEx, CSA, FM, NEPSI, EACEx, Inmetro) None (head mounted and rail mounted transmitter) Without local operation Measuring range setting temperature input: Lower range value (max. 5 characters), Upper range value (max. 5 characters), Unit (C, F) (on type label)
7NG0320-0BA00-0AA0-Z C20
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC, EAC, CSA) None (head mounted and rail mounted transmitter) Without local operation Functional Safety (IEC 61508) - SIL2/3
7NG0327-0BA00-0NA0
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output.
7NG0320-0LA10-0NA0-Z C20+Y01
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 TC Type N None Internal CJC Without enclosure (head mounted and rail mounted transmitter) - Intrinsic safety (Ex i) / Increased safety zone 2 (Ex ec) / Non-incendive (NI) / Non-incendive field wiring (NIFW) (ATEX, IECEx, EACEx, CSA, FM, NEPSI, EACEx, Inmetro) None (head mounted and rail mounted transmitter) Without local operation Functional Safety (IEC 61508) - SIL2/3 Measuring range setting temperature input: Lower range value (max. 5 characters), Upper range value (max. 5 characters), Unit (C, F) (on type label)
7NG0320-0BA00-0NA0
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output.
7NG0320-0BA00-0NA0-Z C20
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Without enclosure (head mounted and rail mounted transmitter) - Intrinsic safety (Ex i) / Increased safety zone 2 (Ex ec) / Non-incendive (NI) / Non-incendive field wiring (NIFW) (ATEX, IECEx, EACEx, CSA, FM, NEPSI, EACEx, Inmetro) None (head mounted and rail mounted transmitter) Without local operation Functional Safety (IEC 61508) - SIL2/3
7NG0320-0JA10-0AA0-Z C11+Y01+Y15
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 TC Type K None Internal CJC Without enclosure (head mounted and rail mounted transmitter) - General purpose (CE, RCM, FM, KCC, EAC, CSA) None (head mounted and rail mounted transmitter) Without local operation Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Measuring range setting temperature input: Lower range value (max. 5 characters), Upper range value (max. 5 characters), Unit (C, F) (on type label) Tag (device parameters, max. 32 characters), adhesive label
7NG0327-0BA00-0AA0
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output.
7NG0320-0BA00-0NA0-Z C11+Y01+Y15
SITRANS TR320 Temperature transmitter for rail mounting, with one configurable input and a galvanically isolated 2-wire output. HART (4 … 20 mA) Input 1 RTD Pt100 IEC 60751 3-wire None None CJC Without enclosure (head mounted and rail mounted transmitter) - Intrinsic safety (Ex i) / Increased safety zone 2 (Ex ec) / Non-incendive (NI) / Non-incendive field wiring (NIFW) (ATEX, IECEx, EACEx, CSA, FM, NEPSI, EACEx, Inmetro) None (head mounted and rail mounted transmitter) Without local operation Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Measuring range setting temperature input: Lower range value (max. 5 characters), Upper range value (max. 5 characters), Unit (C, F) (on type label) Tag (device parameters, max. 32 characters), adhesive label