Cảm biến nhiệt độ –50...+150°C Pt100 4-20mA Sick TCT-1PAG10253MZ | 6043164
Features
| Measuring range |
–50 °C ... +150 °C |
| Sensor element |
Pt100 |
| Output signal |
Pt100, 4-wire |
Mechanics/electronics
| Process connection |
Thread G ¼ B |
| Insertion length/diameter of probe |
25 mm / 3 mm |
| Wetted parts |
Stainless steel 1.4571 |
| Pressure resistance |
Max. 120 bar |
| Housing material |
Stainless steel 1.4571 |
| Electrical connection |
M12 round connector x 1, 4-pin 1) |
| Enclosure rating |
IP67 2) |
| Measuring current |
0.3 mA ... 1 mA |
| Electrical safety |
Protection class: III, dielectric strength: 500 V |
| Protection class III |
✔ |
| RoHS certificate |
✔ |
| Weight |
Ca. 145 g (depending on configuration) |
| Initialization time |
< 10 ms |
1) The enclosure rating classes specified only apply while the thermometer is connected with female connectors that provide the corresponding enclosure rating.
2) IP enclosure rating as per IEC 60529.
Performance
| Accuracy of sensor element |
Class A according to IEC 60751 |
| Transmitter accuracy |
≤ ± 1,0 % of span |
| Transmitter linearity |
≤ 0.1 % of span |
| Response time |
T50: ≤ 2.8 s 1)
t90 ≤ 9,1 s 1)
|
1) Depending on sensor configuration, according to IEC 60751.
Ambient data
| Ambient temperature |
–40 °C ... +125 °C |
| Storage and transport temperature |
–40 °C ... +85 °C |
| Shock resistance according to IEC 60751 |
500 g |
| Vibration resistance according to IEC 60751 |
3 g |
Classifications
| eCl@ss 5.0 |
27200208 |
| eCl@ss 5.1.4 |
27200208 |
| eCl@ss 6.0 |
27200208 |
| eCl@ss 6.2 |
27200208 |
| eCl@ss 7.0 |
27200208 |
| eCl@ss 8.0 |
27200208 |
| eCl@ss 8.1 |
27200208 |
| eCl@ss 9.0 |
27200208 |
| eCl@ss 10.0 |
27200208 |
| eCl@ss 11.0 |
27200208 |
| eCl@ss 12.0 |
27200208 |
| ETIM 5.0 |
EC002994 |
| ETIM 6.0 |
EC002994 |
| ETIM 7.0 |
EC002994 |
| ETIM 8.0 |
EC002994 |
| UNSPSC 16.0901 |
41112211 |
- Tài liệu kỹ thuật Sick TCT-1PAG10253MZ | 6043164