Bộ điều khiển PROFINET Modbus/TCP Phoenix Contact ILC 131 ETH - 2700973
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
Mô tả
The ILC 131 ETH modular small-scale controller for the Inline I/O system is at the heart of Easy Automation. The ILC 1X1 series is characterized by its support for the Modbus/TCP and PROFINET Ethernet-based protocols. A new feature is the support for an optional SD card.
Thông số kỹ thuật
Notes
Utilization restriction |
CCCex note |
Use in potentially explosive areas is not permitted in China. |
Product properties
Type |
modular |
Product type |
Controller |
Product family |
Inline-Controller |
Display |
Diagnostics display |
No |
System properties
Processor |
Altera Nios II 64 MHz |
Retentive data storage |
8 kByte (NVRAM) |
IEC 61131 runtime system |
Program memory |
192 kByte |
Data storage system |
192 kByte |
Number of control tasks |
8 |
INTERBUS-Master |
Amount of process data |
max. 4096 bit (INTERBUS) |
Number of supported devices |
max. 63 |
Number of local bus devices that can be connected |
max. 63 (observe current consumption) |
Number of devices with parameter channel |
max. 8 |
Modbus/TCP-Client |
Amount of process data |
max. 8192 bit (internal Modbus /TCP client) |
Number of Modbus/TCP clients |
max. 4 later than FW 4.42 |
PROFINET |
Device function |
PROFINET device |
Specification |
2.2 |
Device ID |
007Dhex / 125dez |
Vendor ID |
00B0hex / 176dez |
Function |
Diagnostics display |
No |
Controller redundancy |
No |
Safety function |
No |
Functionality |
Programming languages supported |
Instruction list (IL) |
Symbolic flowchart (SFC) |
Ladder diagram (LD) |
Function block diagram (FBD) |
Structured text (ST) |
System requirements |
Engineering tool |
PC Worx |
PC Worx Express |
Configuration tool |
Config+ Version 1.01 or later |
Diagnostics tool |
DIAG+ |
Runtime system |
eCLR |
Application interface |
OPC |
Electrical properties
Transmission medium |
Copper |
Real-time clock |
Realtime clock |
Yes |
Description realtime clock |
integrated (rechargeable battery buffered) |
Potentials: 24 V supply UILC |
Supply voltage |
24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply voltage range |
19.2 V DC ... 30 V DC |
Current draw |
80 mA (without connected I/O terminal blocks) |
Potentials: 7.5 V communications power UL (potential jumper) |
Supply voltage |
7.5 V DC ±5 % |
Potentials: 24 V analog supply UANA (potential jumper) |
Supply voltage |
24 V DC -15 % / +20 % |
Supply voltage range |
19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: 24 V main supply UM |
Supply voltage |
24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply voltage range |
19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw |
max. 8 A DC |
6 mA (without sensors) |
Potentials: 24 V segment supply US |
Supply voltage |
24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply voltage range |
19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw |
max. 8 A DC |
10 mA (without actuators) |
Input data
Digital |
Input name |
Digital inputs |
Description of the input |
EN 61131-2 type 1 NPN/PNP |
Number of inputs |
8 |
Cable length |
max. 30 m |
Connection method |
Inline potential distributor |
Connection technology |
2-, 3-, 4-conductor |
Input voltage range |
-0.5 V ... 30 V |
Input voltage range "0" signal |
-0.5 V ... 5 V |
Input voltage range "1" signal |
15 V ... 30 V |
Nominal input current at UIN |
typ. 7 mA |
max. 15 mA |
Input filter time |
typ. 5 ms (Signal change 01) |
typ. 5 ms () |
Output data
Digital |
Output name |
Digital outputs |
Connection method |
Spring-cage connection |
Connection technology |
2-, 3-, 4-conductor |
Number of outputs |
4 |
Maximum output current per channel |
500 mA |
Maximum output current per module / terminal block |
2 A |
Nominal load, lamp |
12 W |
Nominal load, ohmic |
12 W |
Connection data
Cross section AWG |
(converted acc. to IEC) |
Inline connector |
Connection method |
Spring-cage connection |
Conductor cross section, rigid |
0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible |
0.08 mm² ... 1.5 mm² |
Conductor cross section AWG |
28 ... 16 |
Interfaces
Web server |
yes |
Ethernet |
Bus system |
RJ45 |
Number of interfaces |
1 |
Connection method |
RJ45 jack |
Transmission speed |
10/100 Mbps |
No. of channels |
1 |
INTERBUS local bus (master) |
Number of interfaces |
1 |
Connection method |
Inline data jumper |
Transmission speed |
500 kBaud / 2 MBaud (can be switched) |
Parameterization/operation/diagnostics |
Bus system |
RS-232 |
Number of interfaces |
1 |
Connection method |
6-pos. MINI DIN socket (PS/2) |
Transmission speed |
max. 115.2 kbps |
Transmission physics |
Copper |
No. of channels |
1 |
Dimensions
Width |
80 mm |
Height |
119.8 mm |
Depth |
71.5 mm |
Material specifications
Environmental and real-life conditions
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C ... 55 °C |
Ambient temperature (storage/transport) |
-25 °C ... 85 °C |
Permissible humidity (operation) |
10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) |
10 % ... 95 % (according to DIN EN 61131-2) |
Shock |
25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (operation) |
5g |
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) |
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37 |
Sulfur dioxide (SO2) 10 ±0.3 ppm (test duration: 10 days), hydrogen sulfide (H2S) 1 ±0.3 ppm (test duration: 4 days), both at 25°C and with 75% humidity |
EMC data
Conformance with EMC directives |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst)EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interferenceEN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |
Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 EN 55011 Class A |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Mounting
Mounting type |
DIN rail mounting |
Commercial data
Item number |
2700973 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product key |
DRAAAA |
Catalog page |
Page 48 (C-6-2019) |
GTIN |
4046356665490 |
Weight per piece (including packing) |
378 g |
Weight per piece (excluding packing) |
348.2 g |
Customs tariff number |
85371091 |
Country of origin |
DE |
Classifications
ECLASS
ECLASS-11.0 |
27242207 |
ECLASS-12.0 |
27242207 |
ECLASS-13.0 |
27242207 |
ETIM
UNSPSC
Approvals
EAC
Approval ID: RU*DE*08.B.00529/19
DNV GL
Approval ID: TAA00002CU
LR
Approval ID: LR22191720TA
BV
Approval ID: 20989_C0 BV
BSH
Approval ID: 858
RINA
Approval ID: ELE121121XG
ABS
Approval ID: 22-2226444-PDA
cULus Listed
Approval ID: FILE E 238705
UAE-RoHS
Approval ID: 22-04-13087
EAC
Approval ID: RU*DE*08.B.00529/19
ABS
Approval ID: 22-2226444-PDA
BSH
Approval ID: 858
DNV GL
Approval ID: TAA00002CU
RINA
Approval ID: ELE121121XG
LR
Approval ID: LR22191720TA
cULus Listed
Approval ID: FILE E 238705
UAE-RoHS
Approval ID: 22-04-13087
IECEx
Approval ID: IECEX TUR 20.0099
cULus Listed
Approval ID: FILE E 199827
X
ATEX
Approval ID: TÜV 20 ATEX 8619 X
cULus Listed
Approval ID: FILE E 199827
Environmental product compliance
|
REACh SVHC |
Lead 7439-92-1 |
|
China RoHS |
Environmentally Friendly Use Period = 50 years |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
- Tài liệu kỹ thuật Phoenix Contact ILC 131 ETH - 2700973
ở đây.
Accessories
COM CAB MINI DIN - Connecting cable
2400127
SD FLASH 512MB - Program / configuration memory
2988146
SD FLASH 512MB APPLIC A - Program / configuration memory
2701799
SD FLASH 512MB PDPI BASIC - Memory
2701800
SD FLASH 512MB PDPI PRO - Memory
2701801
SD FLASH 2GB - Program / configuration memory
2988162
SD FLASH 2GB APPLIC A - Program / configuration memory
2701190
AX OPC SERVER - Driver and interface software
2985945
IPASSIGN - Software
2701094
PC WORX UA SERVER-PLC 10 - Driver and interface software
2402684
PC WORX UA SERVER-PLC 40 - Driver and interface software
2402685
PC WORX UA SERVER-PLC 80 - Driver and interface software