Bộ lưu điện UPS 1AC 24DC 5A Phoenix Contact TRIO-UPS-2G/1AC/24DC/5 - 2907160

Bộ lưu điện UPS 1AC 24DC 5A Phoenix Contact TRIO-UPS-2G/1AC/24DC/5 - 2907160

308
Nhà sản xuất: Phoenix Contact;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Bộ lưu điện UPS 1AC 24DC 5A Phoenix Contact TRIO-UPS-2G/1AC/24DC/5 - 2907160

TRIO UPS - UPS with integrated power supply, USB (Modbus/RTU), DIN rail mounting, Push-in connection, input: 1-phase, output: 24 V DC / 5 A
 

 

Product description

Supply DC loads reliably and save space with the TRIO uninterruptible power supplies. An input grid is no longer necessary for startup. Connected industrial PCs can be shut down easily via the integrated USB interface.

 

Technical data

Input data

Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
Voltage type of supply voltage AC
Inrush current < 16 A
Inrush current integral (I2t) < 0.43 A2s
Frequency range (fN) 50 Hz ... 60 Hz (±10 %)
Mains buffering time ≥ 15 ms (120 V AC)
Switch-on time typ. 60 ms
Typical current consumption 3.3 A (100 V AC)
Input fuse 6.3 A (slow-blow, internal)
Signal Bat.-Start
Connection labeling 3.6
Signalization designation Bat.-Start
Low signal Connection to SGnd with < 2.7 kΩ
High signal Open (> 200 kΩ between Bat.-Start and SGnd)
Signal Remote
Connection labeling 3.5
Signalization designation Remote
Low signal Connection to SGnd with < 2.7 kΩ
High signal Open (> 35 kΩ between Remote and SGnd)
 

Output data

Efficiency typ. 85 % (120 V AC)
typ. 87 % (230 V AC)
typ. 96 % (Battery operation)
Derating > 60 °C (2.5%/K of POut nom.)
Crest factor 2.7 (120 V AC)
3.2 (230 V AC)
Switch-over time < 75 ms
UPS connection in parallel yes, with diode module uncoupled
UPS connection in series no
Energy storage device connection in parallel yes
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) < 30 V DC
Residual ripple < 20 mV
Control deviation < 0.75 % (change in load, static 10 % ... 90 %)
< 1.25 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Rise time < 15 ms
Permissible backup fuse B10
Mains operation
Output voltage 24 V DC
Output voltage range 24 V DC ... 28 V DC (> 24 V constant capacity)
Output current IN 5 A
Dynamic Boost (IDyn.Boost) 7.5 A
Output power POUT (UN, IOUT = IN) 120 W
Maximum no-load power dissipation < 3 W (230 V AC)
Power loss nominal load max. < 19 W (230 V AC)
Battery operation
Output voltage UBAT -0.1 V DC
Output voltage range 18 V DC ... 30 V DC
Output current IN 5 A
Dynamic Boost (IDyn.Boost) 7.5 A
Signal Alarm
Connection labeling 3.2
Signalization designation Alarm
Type of signaling LED red
Switching output Transistor output, active
Output voltage 24 V DC
Continuous load current 20 mA
LED status indicator red
Signal Battery mode
Connection labeling 3.3
Signalization designation Battery mode
Type of signaling Yellow LED
Switching output Transistor output, active
Output voltage 24 V DC
Continuous load current 20 mA
LED status indicator yellow
Signal DC OK
Connection labeling 3.1
Signalization designation DC OK
Type of signaling Green LED
Switching output Transistor output, active
Output voltage 24 V DC
Continuous load current 20 mA
LED status indicator green
Signal Ready
Connection labeling 3.4
Signalization designation Ready
Switching output Transistor output, active
Output voltage 24 V DC
Continuous load current 20 mA
Signal supply 24 V DC, 20 mA, SGnd
Connection labeling 3.7
 

Energy storage

Nominal voltage UN 24 V DC
End-of-charge voltage max. 30 V DC
Charging current (Configurable) 0.2 A ... 1.5 A (-25 °C ... 40 °C)
Charging current (Reduced) 1.5 A ... 0 A (40 °C ... 65 °C)
Charging current (Preset) 1.2 A (-25 °C ... 40 °C)
Charging current () 1.5 A
Nominal capacity range 1.2 Ah ... 12 Ah
Battery technology VRLA-AGM
Charge characteristic curve IU0U
 

Connection data

Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 4 mm²
flexible 0.2 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve 0.25 mm² ... 1.5 mm²
rigid (AWG) 24 ... 12
Stripping length 10 mm
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 4 mm²
flexible 0.2 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve 0.25 mm² ... 1.5 mm²
rigid (AWG) 24 ... 12
Stripping length 10 mm
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 1.5 mm²
flexible 0.2 mm² ... 1.5 mm²
flexible with ferrule without plastic sleeve 0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve 0.2 mm² ... 0.75 mm²
rigid (AWG) 24 ... 16
Stripping length 8 mm
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 10 mm²
flexible 0.2 mm² ... 6 mm²
flexible with ferrule without plastic sleeve 0.25 mm² ... 6 mm²
flexible with ferrule with plastic sleeve 0.25 mm² ... 4 mm²
rigid (AWG) 24 ... 8
Stripping length 15 mm
 

Interfaces

Interface USB (Modbus/RTU)
Number of interfaces 1
Connection method MINI-USB Type B
Locking Screw
 

Electrical properties

Number of phases 1.00
Insulation voltage input/output 3 kV AC (type test)
1.5 kV AC (routine test)
Insulation voltage output / PE 500 V AC (type test)
500 V AC (routine test)
Insulation voltage input / PE 1.5 kV AC (type test)
1.5 kV AC (routine test)
 

Product properties

Product type DC UPS with integrated power supply
Product family TRIO UPS
MTBF (IEC 61709, SN 29500) > 1395470 h (230 V AC, at 25 °C)
> 825726 h (230 V AC, at 40 °C)
> 388314 h (230 V AC, at 60 °C)
Insulation characteristics
Protection class I
Degree of pollution 2
Life expectancy (electrolytic capacitors)
Current 5 A
Temperature 40 °C
Additional text 230 V AC
 

Dimensions

Item dimensions
Width 115 mm
Height 130 mm
Depth 60 mm
Installation dimensions
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 50 mm / 50 mm
 

Mounting

Mounting type DIN rail mounting
Assembly instructions alignable: horizontally 0 mm, vertically 50 mm
Mounting position horizontal DIN rail NS 35, EN 60715
 

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks) V0
Housing material Metal
Hood version PC
Side element version Aluminum
 

Environmental and real-life conditions

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Ambient temperature (start-up type tested) -40 °C
Maximum altitude ≤ 4000 m (> 2000 m, observe derating)
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (At +25°C, non-condensing)
Shock 30g, 18 ms in accordance with IEC 60068-2-27
Vibration (operation) < 12 ... 13.2 Hz, amplitude ±1 mm, 13.2 ... 100 Hz, 0.7g
in accordance with IEC 60068-2-6
 

Standards and regulations

Overvoltage category
EN 61010-1 II
Safety for measurement, control, and laboratory equipment
Standard designation Safety for equipment for measurement, control, and laboratory use
Standards/specifications IEC 61010-1
Protective extra-low voltage
Standard designation Protective extra-low voltage
Standards/specifications IEC 61010 (SELV) / (PELV)
Safe isolation
Standard designation Safe isolation
Standards/specifications DIN VDE 0100-410
Low-voltage power supplies, DC output
Standard designation Low-voltage power supplies, DC output
Standards/specifications EN 61204-3
Ship’s bridge
Standard designation Ship’s bridge
Standards/specifications IEC/EN 60945
 

Approvals

UL
Identification UL Listed UL 61010
UL
Identification UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C
Shipbuilding
Identification DNV
Shipbuilding
Identification LR
 

EMC data

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Noise immunity Immunity in accordance with EN 61000-6-2 (industrial)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Conducted noise emission EN 61000-6-3
Noise emission EN 61000-6-3
DNV GL conducted interference Class B
Additional text Area power distribution
DNV GL noise radiation Class B
Additional text Bridge and deck area
Harmonic currents
Standards/regulations EN 61000-3-2
Flicker
Standards/regulations EN 61000-3-3
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 6 kV (Test Level 3)
Discharge in air 8 kV (Test Level 3)
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 6 GHz
Test field strength 10 V/m
Frequency range 1.4 GHz ... 6 GHz
Test field strength 3 V/m
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 4 kV
Output 2 kV
Signal 2 kV
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V
 

Commercial data

Item number 2907160
Packing unit 1 pc
Minimum order quantity 1 pc
Product key CMUO13
Catalog page Page 354 (C-4-2019)
GTIN 4055626166575
Weight per piece (including packing) 957.8 g
Weight per piece (excluding packing) 741 g
Customs tariff number 85044083
Country of origin CN
 

Classifications

ECLASS

ECLASS-11.0 27040705
ECLASS-13.0 27040705
ECLASS-12.0 27040705
 

ETIM

ETIM 8.0 EC000382
 

UNSPSC

UNSPSC 21.0 39121000
 

Approvals

DNV

Approval ID: TAA00002DW
 

IECEE CB Scheme

Approval ID: DK-63811-UL

EAC

Approval ID: RU S-DE.BL08.W.00764

LR

Approval ID: LR2002877TA

EAC

Approval ID: RU-DE.B.00184/20

UL Listed

Approval ID: FILE E 123528

cUL Listed

Approval ID: FILE E 123528

BSH

Approval ID: 1025a

KC

Approval ID: R-R-PCK-2907160

cUL Listed

Approval ID: FILE E 199827

UL Listed

Approval ID: FILE E 199827
 

cULus Listed

 

cULus Listed

 

Environmental product compliance

 
REACh SVHC Lead 7439-92-1
 
China RoHS Environmentally Friendly Use Period = 25;
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”



- Tài liệu kỹ thuật Phoenix Contact TRIO-UPS-2G/1AC/24DC/5 - 2907160 ở đây.

 

Compatible products

Energy storage
UPS-BAT/PB/24DC/1.2AH - 1274520
Energy storage
UPS-BAT/PB/24DC/4AH - 1274117
Energy storage
UPS-BAT/PB/24DC/7AH - 1274118
Energy storage
UPS-BAT/PB/24DC/12AH - 1274119
Energy storage
UPS-BAT/PB/24DC/20AH - 1348516
Energy storage
UPS-BAT/PB/24DC/40AH - 1354641
Energy storage
UPS-BAT/VRLA-WTR/24DC/26AH - 2320429
Energy storage
UPS-BAT/VRLA-WTR/24DC/13AH - 2320416
Data cable
MINI-SCREW-USB-DATACABLE - 2908217
Mounting adapter
UWA 130 - 2901664
Mounting adapter
UWA 182/52 - 2938235
SẢN PHẨM XEM NHIỀU
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại