Bộ lưu điện UPS DC 24V 60W 0.8Ah Phoenix Contact UNO-UPS/24DC/24DC/60W - 2905907
Uninterruptible energy supply with integrated energy storage, lead AGM, VRLA technology, 24 V DC, 0.8 Ah.
Product description
UPS modules with integrated energy storage are particularly space saving: UPS module and energy storage are combined in one housing. It's just a case of connecting a power supply upstream.
Technical data
Input data
| DC operation |
| Input voltage |
24 V DC |
| Input voltage range |
22.5 V DC ... 29.5 V DC |
| Voltage type of supply voltage |
DC |
| Buffer period |
45 min. (0.5 A) |
| 20 min. (1 A) |
| 8 min. (2 A) |
| 5 min. (2.5 A) |
| Current consumption |
2.8 A (max.) |
| < 60 mA |
| < 300 mA |
| Input fuse |
5 A (electronic) |
Output data
| Efficiency |
> 95 % (Mains operation, with charged energy storage) |
| > 92 % (Battery operation) |
| Nominal output voltage |
24 V DC |
| Nominal output current (IN) |
2.5 A |
| Bridging time |
300 s |
| Output power |
60 W |
| Power dissipation |
3 W (Mains operation) |
| 6 W (Battery operation) |
| Battery operation |
| Connection in series |
No |
| Mains operation |
| Nominal output voltage |
24 V DC |
| Output voltage range |
Input voltage - 0.5 V DC |
| Nominal output current (IN) |
2.5 A |
| Battery operation |
| Nominal output voltage |
24 V DC |
| Output voltage range |
20 V DC ... 27.3 V DC |
| Nominal output current (IN) |
2.5 A |
| Signal: Alarm |
| Output description |
Transistor (24 V DC/15 mA) |
| Signal: Battery mode |
| Output description |
Transistor (24 V DC/15 mA) |
Energy storage
| Charging current |
200 mA |
| Nominal capacity |
2x 0.8 Ah |
| Charging time |
approx. 5 h |
| Battery module service life |
3 Years ... 5 Years (20 °C) |
| Latest startup date (battery only) |
3 Months (0 °C ... 20 °C) |
| 1 Months (30 °C ... 40 °C) |
| Latest startup (battery only) - range |
3 Months ... 1 Months (20 °C ... 30 °C) |
| Battery technology |
VRLA |
| Memory medium |
Lead rechargeable battery module |
| Accumulator type |
YUASA NP0.8-12 / YUCEL Y0.8-12 |
| Battery presence check (cyclic) |
60 s |
| Battery fuse |
T 5 A 32 V |
| IQ technology |
no |
Connection data
| Input |
| Connection method |
Screw connection |
| Conductor cross section, rigid min. |
0.2 mm² |
| Conductor cross section, rigid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
14 |
| Stripping length |
7 mm |
| Screw thread |
M3 |
| Tightening torque, min |
0.5 Nm |
| Tightening torque max |
0.6 Nm |
| Output |
| Connection method |
Screw connection |
| Conductor cross section, rigid min. |
0.2 mm² |
| Conductor cross section, rigid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
14 |
| Stripping length |
7 mm |
| Screw thread |
M3 |
| Tightening torque, min |
0.5 Nm |
| Tightening torque max |
0.6 Nm |
| Signal |
| Connection method |
Screw connection |
| Conductor cross section, rigid min. |
0.2 mm² |
| Conductor cross section, rigid max. |
2.5 mm² |
| Conductor cross section flexible min. |
0.2 mm² |
| Conductor cross section flexible max. |
2.5 mm² |
| Conductor cross section AWG min. |
24 |
| Conductor cross section AWG max. |
14 |
| Stripping length |
7 mm |
| Screw thread |
M3 |
| Tightening torque, min |
0.5 Nm |
| Tightening torque max |
0.6 Nm |
Signaling
| Types of signaling |
LED |
| Signal output |
| Signalization designation |
Power In OK |
| Status display |
LED |
| Note on status display |
Static to |
| Signal output: Switching output |
| Signalization designation |
Alarm |
| Status display |
LED |
| Note on status display |
Static to |
| Signal output |
| Status display |
LED |
| Note on status display |
flashing |
| Signal output: Switching output |
| Signalization designation |
Battery mode |
| Status display |
LED |
| Note on status display |
flashing |
| Signal output |
| Signalization designation |
Service |
| Status display |
LED |
| Note on status display |
flashing |
Product properties
| Product type |
DC UPS with integrated energy storage |
| Product family |
UNO UPS ‒ UPS with integrated energy storage |
| IQ technology |
no |
| MTBF (IEC 61709, SN 29500) |
> 1900000 h (40 °C) |
| Insulation characteristics |
| Protection class |
III |
| Degree of pollution |
2 |
| Life expectancy (electrolytic capacitors) |
| Time |
170312 h |
Dimensions
| Width |
110 mm |
| Height |
90 mm |
| Depth |
84 mm |
| Installation dimensions |
| Installation distance right/left |
0 mm / 0 mm (≤ 70 °C) |
| Installation distance top/bottom |
30 mm / 30 mm (≤ 70 °C) |
Mounting
| Mounting type |
DIN rail: 35 mm |
| Assembly instructions |
alignable: 0 mm horizontally, 30 mm vertically |
| Mounting position |
horizontal DIN rail NS 35, EN 60715 |
Material specifications
| Housing material |
Plastic |
| Type of housing |
Plastic |
| Foot latch material |
POM (Polyoxymethylene) |
| Housing material |
PC+ABS |
Environmental and real-life conditions
| Ambient conditions |
| Degree of protection |
IP20 |
| Ambient temperature (operation) |
-15 °C ... 50 °C |
| Ambient temperature (storage/transport) |
-20 °C ... 60 °C |
| Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
| Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) |
< 13.2 Hz, amplitude ±1.0 mm (according to IEC 60068-2-6) |
| 13.2 Hz ... 100 Hz, 0.7g |
Standards and regulations
| Standard - Electrical safety |
IEC 62368-1 (SELV) |
Approvals
| UL approvals |
UL Listed UL 508 |
| UL/C-UL Recognized UL 60950-1 |
EMC data
| EMC requirements for noise emission |
EN 61000-6-3 |
| EN 61000-6-4 |
| EMC requirements for noise immunity |
EN 61000-6-1 |
| EN 61000-6-2 |
| Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
| Electrostatic discharge |
| Standards/regulations |
EN 61000-4-2 |
| Electrostatic discharge |
| Contact discharge |
6 kV (Test Level 3) |
| Discharge in air |
8 kV (Test Level 3) |
| Comments |
Criterion A |
| Electromagnetic HF field |
| Standards/regulations |
EN 61000-4-3 |
| Electromagnetic HF field |
| Frequency range |
80 MHz ... 3 GHz |
| Test field strength |
10 V/m (Test Level 3) |
| Comments |
Criterion A |
| Fast transients (burst) |
| Standards/regulations |
EN 61000-4-4 |
| Fast transients (burst) |
| Input |
2 kV (Test Level 3 - asymmetrical) |
| Output |
2 kV (Test Level 3 - asymmetrical) |
| Signal |
2 kV (Test Level 4 - asymmetrical) |
| Comments |
Criterion A |
| Surge voltage load (surge) |
| Standards/regulations |
EN 61000-4-5 |
| Input |
1 kV (Test Level 3 - symmetrical) |
| 2 kV (Test Level 3 - asymmetrical) |
| Output |
1 kV (Test Level 3 - symmetrical) |
| 2 kV (Test Level 3 - asymmetrical) |
| Signal |
1 kV (Test Level 2 - asymmetrical) |
| Comments |
Criterion A |
| Conducted interference |
| Standards/regulations |
EN 61000-4-6 |
| Conducted interference |
| I/O/S |
asymmetrical |
| Frequency range |
0.15 MHz ... 80 MHz |
| Comments |
Criterion A |
| Voltage |
10 V (Test Level 3) |
| Emitted interference |
| Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Criteria |
| Criterion A |
Normal operating behavior within the specified limits. |
| Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Commercial data
| Item number |
2905907 |
| Packing unit |
1 pc |
| Minimum order quantity |
1 pc |
| Product key |
CMUUV3 |
| Catalog page |
Page 349 (C-4-2019) |
| GTIN |
4055626007380 |
| Weight per piece (including packing) |
1,182 g |
| Weight per piece (excluding packing) |
1,182 g |
| Customs tariff number |
85371091 |
| Country of origin |
DE |
Classifications
ECLASS
| ECLASS-11.0 |
27040705 |
| ECLASS-13.0 |
27040705 |
| ECLASS-12.0 |
27040705 |
ETIM
UNSPSC
Approvals
cUL Recognized
Approval ID: FILE E 214596
UL Recognized
Approval ID: FILE E 214596
IECEE CB Scheme
Approval ID: DK-47330-A1-UL
EAC
Approval ID: RU S-DE.BL08.W.00764
UL Listed
Approval ID: FILE E 123528
cUL Listed
Approval ID: FILE E 123528
EAC
Approval ID: RU S-DE.BL08.W.00764
KC
Approval ID: R-R-PCK-2905907
UL Recognized
Approval ID: FILE E 214596
IECEE CB Scheme
Approval ID: DK-47330-A1-UL
cUL Recognized
Approval ID: FILE E 214596
cUL Listed
Approval ID: FILE E 123528
UL Listed
Approval ID: FILE E 123528
EAC
Approval ID: RU-DE.B.00184/20
EAC
Approval ID: RU-DE.B.00184/20
KC
Approval ID: R-R-PCK-2905907
Environmental product compliance
| |
| REACh SVHC |
Lead 7439-92-1 |
| |
| China RoHS |
Environmentally Friendly Use Period = 25; |
| For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
- Tài liệu kỹ thuật Phoenix Contact UNO-UPS/24DC/24DC/60W - 2905907
ở đây.
Compatible products
Power supply unit
UNO-PS/1AC/24DC/ 60W - 2902992
Power supply unit
UNO-PS/1AC/24DC/100W - 2902993
Fuse
FUSE 5A/32V FK-1 - 2908367