7MC7111-6BA21-ZE00J01Y15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 1 m PVC/PVC (JJ) TAG plate TAG in plain text Stainless steel
7MC7111-6BB31-ZE00J05
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 5 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J06
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 6 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ04
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 4 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ02
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 2 m PVC/PVC (JJ)
7MC7111-6CA21-ZA20E00S10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 101 ... 250; Initial: 200 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Flying leads, IP00 Soldering nipple G1/4" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 10 m Silicone / Fluoropolymer(SLFP)
7MC7111-6DA21-ZA30E00S15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 251 ... 500; Initial: 500 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Flying leads, IP00 Compression fitting G 1/4" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 15 m Silicone / Fluoropolymer(SLFP)
7MC7111-6BA11-ZE00J01
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 1 m PVC/PVC (JJ)
7MC7111-6CA11-ZE00J25Y33
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 101 ... 250; Initial: 200 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 25 m PVC/PVC (JJ) Carry out factory calibration at one point, specify desired temperature in plain text
7MC7111-6BA11-ZE00J15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 15 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J04
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 4 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J30
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 30 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J50
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 50 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 10 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ30
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 30 m PVC/PVC (JJ)
7MC7111-6BA11-ZE00L15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 15 m PTFE / Glass silk / VA (TGLV)
7MC7111-6BA41-ZA31E00J20
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 20 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ99
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 99 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J99
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 99 m PVC/PVC (JJ)
7MC7111-6BA41-ZA50E00J03
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Surface connection piece, aluminum, enclosed Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 3 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 15 m PVC/PVC (JJ)
7MC7111-6BB41-ZE00L05Y15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 5 m PTFE / Glass silk / VA (TGLV) TAG plate TAG in plain text Stainless steel
7MC7111-6BA41-ZE00J10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 10 m PVC/PVC (JJ)
7MC7111-6CA41-ZA31E00J10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 101 ... 250; Initial: 200 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 10 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ15
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 15 m PVC/PVC (JJ)
7MC7111-6GA23-ZE00J10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 1001 ... 1500; Initial: 1500 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Connector M12x1, IP54 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 10 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ50
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 50 m PVC/PVC (JJ)
7MC7111-6BA41-ZE00J02
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Requirements non-Ex Connecting cable; LC = 2 m PVC/PVC (JJ)
7MC7111-6BA41-ZJ06
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Connecting cable; LC = 6 m PVC/PVC (JJ)
7MC7111-6BB11
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00
7MC7111-6BB41
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00
7MC7111-6EK21
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 501 ... 750; Initial: 750 mm Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.1 -40 ... 1000Cel Electrical connection end: Flying leads, IP00
7MC7111-6BK21
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.1 -40 ... 1000Cel Electrical connection end: Flying leads, IP00