Cảm biến lưu lượng 0.2-100l/min 16bar G1-DN25 IFM SM8004 | SMR11GGX50KG/US100
Magnetic-inductive flow meter
SM8004
SMR11GGX50KG/US100
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- With two precise analogue outputs
- Clearly visible 4-digit LED display
Product characteristics
Number of inputs and outputs |
Number of analogue outputs: 2 |
Measuring range |
0.2...100 l/min |
0.1...26.4 gpm |
|
Process connection |
threaded connection G 1 DN25 flat seal |
Application
Special feature |
Gold-plated contacts |
Application |
for industrial applications |
Installation |
connection to pipe by means of an adapter |
Media |
conductive liquids; water; hydrous media |
Note on media |
conductivity: ≥ 20 µS/cm |
viscosity: < 70 mm²/s (40 °C) |
|
Medium temperature [°C] |
-10...70 |
Pressure rating [bar] |
16 |
Pressure rating [MPa] |
1.6 |
MAWP (for applications according to CRN) [bar] |
11.2 |
Electrical data
Operating voltage [V] |
20...30 DC; (to SELV/PELV) |
Current consumption [mA] |
120; (24 V) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
5 |
Inputs / outputs
Number of inputs and outputs |
Number of analogue outputs: 2 |
Outputs
Total number of outputs |
2 |
Output signal |
analogue signal |
Number of analogue outputs |
2 |
Analogue current output [mA] |
4...20; (scalable) |
Max. load [Ω] |
500 |
Overload protection |
yes |
Measuring/setting range
Measuring range |
0.2...100 l/min |
0.1...26.4 gpm |
|
Display range |
-120...120 l/min |
-31.7...31.7 gpm |
|
Resolution |
|
Analogue start point ASP |
0...80 l/min |
0...21.1 gpm |
|
Analogue end point AEP |
20...100 l/min |
5.3...26.4 gpm |
|
In steps of |
|
Temperature monitoring
Measuring range [°C] |
-20...80 |
Resolution [°C] |
0.2 |
Analogue start point [°C] |
-20...60 |
Analogue end point [°C] |
0...80 |
In steps of [°C] |
0.2 |
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) |
± (2 % MW + 0,5 % MEW) |
Repeatability |
± 0,2% MEW |
Temperature monitoring
Accuracy [K] |
± 2,5 (Q > 1 l/min) |
Response times
Flow monitoring
Response time [s] |
0.15; (dAP = 0, T19) |
Damping process value dAP [s] |
0...3 |
Temperature monitoring
Dynamic response T05 / T09 [s] |
T09 = 20 (Q > 1 l/min) |
Operating conditions
Ambient temperature [°C] |
-10...60 |
Storage temperature [°C] |
-25...80 |
Protection |
IP 67 |
Tests / approvals
EMC |
DIN EN 60947-5-9 |
500 V withstand voltage (V DC) |
|
CPA approval |
model number |
009MI |
accuracy class |
- |
maximum allowable error |
± 2,5 % FS |
Q (min) |
0,01 m³/h |
Q (t) |
- |
Q (max) |
6 m³/h |
|
Shock resistance |
DIN IEC 68-2-27 |
20 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
5 g (10...2000 Hz) |
|
MTTF [years] |
175 |
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
Weight [g] |
576.9 |
Materials |
stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); PEEK; FKM |
Process connection |
threaded connection G 1 DN25 flat seal |
Displays / operating elements
Display |
Display unit |
6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) |
measured values |
alphanumeric display, 4-digit |
programming |
alphanumeric display, 4-digit |
|
Display unit |
l/min; m³/h; gpm; gph; °C; °F |
Remarks
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
|
Pack quantity |
1 pcs. |
Electrical connection
Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |