Cảm biến nhiệt độ Siemens 7MC7111-6BA21
Product |
Article Number (Market Facing Number) |
7MC7111-6BA21 |
Product Description |
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Flying leads, IP00 |
Product family |
SITRANS TS100, cable version, mineral-insulated |
Product Lifecycle (PLM) |
PM300:Active Product |
Price data |
Price Group / Headquarter Price Group |
8T3 |
List Price |
Show prices |
Customer Price |
Show prices |
Metal Factor |
None |
Delivery information |
Export Control Regulations |
ECCN : EAR99I / AL : N |
Standard lead time ex-works |
13 Day/Days |
Net Weight (kg) |
1.039 Kg |
Package size unit of measure |
Not available |
Quantity Unit |
1 Piece |
Packaging Quantity |
1 |
Additional Product Information |
EAN |
Not available |
UPC |
Not available |
Commodity Code |
Not available |
LKZ_FDB/ CatalogID |
FI01-3 |
Product Group |
4785 |
Group Code |
R3P0 |
Country of origin |
France |
Compliance with the substance restrictions according to RoHS directive |
Since: 19/06/15 |
Product class |
C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
WEEE (2012/19/EU) Take-Back Obligation |
Yes |
REACH Art. 33 Duty to inform according to the current list of candidates |
|
Classifications |
|
|
Version |
Classification |
eClass |
12 |
27-20-02-14 |
eClass |
6 |
27-20-02-14 |
eClass |
7.1 |
27-20-02-14 |
eClass |
8 |
27-20-02-14 |
eClass |
9 |
27-20-02-14 |
eClass |
9.1 |
27-20-02-14 |
UNSPSC |
15 |
32-15-17-03 |
|
Tham khảo các model khác cùng loại:
7MC7111-6CB11-Z E00+S05+Y44
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 101 ... 250; Initial: 200 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 5 m Silicone / Fluoropolymer(SLFP) Length options: Specify special inst. length (in spec. area)
7MC7111-6DA13-Z C12+C25+C34+C35+E01+S13
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 251 ... 500; Initial: 500 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Connector M12x1, IP54 Inspection certificate DIN EN 10204-3.1: Material Certificates: Callendar Van Dusen coeff. calibrated at 0/+ 50/+100°C Inspection certificate DIN EN 10204-3.1: Visual, dimensional, and functional inspection Compliance declaration DIN EN 10204-2.1: Declaration of compliance with the order Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Connecting cable; LC = 13 m Silicone / Fluoropolymer(SLFP)
7MC7111-6BB31-Z A50+E00+J10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Surface connection piece, aluminum, enclosed Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 10 m PVC/PVC (JJ)
7MC7111-6BA31-Z A32+E01+J10
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Electrical connection end: Flying leads, IP00 Compression fitting NPT 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Connecting cable; LC = 10 m PVC/PVC (JJ)
7MC7111-6CK21-Z E00+J01
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 101 ... 250; Initial: 200 mm Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.1 -40 ... 1000Cel Electrical connection end: Flying leads, IP00 Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 1 m PVC/PVC (JJ)
7MC7111-6BB31-Z A50+E00+J01
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Surface connection piece, aluminum, enclosed Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 1 m PVC/PVC (JJ)
7MC7111-6XB23-Z A31+E00+J10+Y44+Y99
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B= Special length-less than 70 mm or greather than 1500 mm (Y44, Y99 required in addition) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Electrical connection end: Connector M12x1, IP54 Compression fitting G 1/2" (enclosed) Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 10 m PVC/PVC (JJ) Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain text
7MC7111-6BB31-Z A50+E00+J05
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Surface connection piece, aluminum, enclosed Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 5 m PVC/PVC (JJ)
7MC7111-6BA21-Z E01+S02
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 70 ... 100; Initial: 100 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Connecting cable; LC = 2 m Silicone / Fluoropolymer(SLFP)
7MC7111-6CA21-Z E01+J01+Y44
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 101 ... 250; Initial: 200 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Electrical connection end: Flying leads, IP00 Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Connecting cable; LC = 1 m PVC/PVC (JJ) Length options: Specify special inst. length (in spec. area)
7MC7111-6DA11-Z E00+J05+Y44
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 251 ... 500; Initial: 500 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Electrical connection end: Flying leads, IP00 Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 5 m PVC/PVC (JJ) Length options: Specify special inst. length (in spec. area)
7MC7111-6DB11-Z E00+S05+Y44
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 251 ... 500; Initial: 500 mm Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Electrical connection end: Flying leads, IP00 Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 5 m Silicone / Fluoropolymer(SLFP) Length options: Specify special inst. length (in spec. area)
7MC7111-6DK21-Z E00+L06
SITRANS TS100 Temperature sensor with directly connected cable, mineral-insulated design Diameter of the measuring tip: 6mm Sensor length (mm): B = Length range: 251 ... 500; Initial: 500 mm Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.1 -40 ... 1000Cel Electrical connection end: Flying leads, IP00 Requirements non-Ex IECEx) For EU / Australia Connecting cable; LC = 6 m PTFE / Glass silk / VA (TGLV)